Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 23736, 2024 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-39390069

RESUMEN

The industrial sector of Pakistan is currently facing severe load-shedding, which ultimately affects its unit production. The greater dependency on conventional energy resources (Thermal, Nuclear, etc.) results in higher production costs and environmental pollution. A sustainable, cost-effective, and environment-friendly solution can help the industrial growth of Pakistan. This article proposes an optimal hybrid energy system (HES) for the industrial sector of Pakistan to overcome the mentioned challenges. The proposed HES is developed in HOMER Pro. Three different energy cases (Case I: Existing energy system including a utility grid and diesel generator, Case II: On-grid Biogas system, and Case III: On-grid PV system with batteries) are considered for the Gourmet food Industry in the Sundar Industrial estate, Pakistan. The Load profile of the selected site was calculated through on-site visits and data provided by the designated utility grid feeder. The analysis shows that Case III is more effective than other cases, indicating reduced Net Present Cost (NPC), Cost of Energy (COE), and Operating Cost (OC) to $ 19.2 million, $0.034/kWh, and $ 573,371/year respectively. Moreover, the On-grid PV system with batteries (Case III) provides an environmentally friendly solution by reducing 63.82% [Formula: see text] by and 62.22% [Formula: see text]. Comparing the sensitivity analysis for various grid sell-back prices ($0/kWh, $0.043/kWh, $0.061/kWh, and $0.09/kWh), Case III is more cost-effective than Case II. The revenue generation in Case III is $128,499.41/yr, considering the supply of excess electricity into nearby small industrial loads at $0.065/kWh, this indicates that installing optimal HES in industries will not only help in overall cost reduction but also support in mitigating environmental pollution and load shedding.

2.
Heliyon ; 9(11): e21426, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38027710

RESUMEN

The use of renewable energy resources for off-grid electricity production has gained more importance in recent decades for meeting the energy needs of remote areas, even with limited resources. This research aims to provide an optimized and cost-effective approach for generating electricity in rural areas. By using current methodology, a stand alone energy source of PV is designed for development of NZE village. Solar irradiance of the selected location is 6.16 kWh/m2/day while the estimated electric load data for whole village is 64.259 kWh. Electric load and solar irradiance of the loaction is used in the Hybrid Optimization Model for Electric Renewable (HOMER) to design and analyze the techno-economic feasibility of the stand alone PV system to meet the load requirements. The study obtained the total Net Present Cost (NPC) of $0.511 M and the Cost Of Electricity (COE) is 2.26$/unit through the HOMER analysis, which is further refined by performing sensitivity analysis using parameters such as PV panel price, battery price, solar irradiance, variations in electric load and discount rates. According to the results, system is feasibile by annual electricity production of 30,078 kWh with initial capital investment of $0.434 M. This analysis compared the system performance and showed that it is economically and technically viable to meet the complete electricity needs of the village with a payback period of 7.2 years. Research can be utilized for policy making and implementation of NZE approach in remote areas by the government.

3.
Environ Sci Pollut Res Int ; 30(28): 71754-71765, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34499303

RESUMEN

In this paper, the technical-economic framework for designing of water pumping system based on photovoltaic clean energy with water tank storage is presented to supply drinking water of customers for remote areas. The objective function is to minimize the net present cost (NPC) (as economic index) including initial investment costs, maintenance, and replacement costs, and reliability constraint is defined as customer's water not supplied probability (CWNSP) as technical index. A meta-heuristic intelligent water drops algorithm (IWDA) is proposed to optimize the solar water pumping system considering NPC and CWNSP with high accuracy and speed of optimization in achieving the global solution. The simulation results show that the proposed method is capable of responding to customer's water demand by optimally sizing components and water storage tank based on IWDA which is inspired based on flowing the water drops in rivers by achieving the lowest cost with optimal reliability. The NPC of the system with CWNSP equal to 3.17 % is obtained 0.24 M$ for 6-m-high water extraction. The results showed that with increasing the water extraction height, the NPC increased, and the reliability also weakened. Moreover, the superiority of the IWDA is confirmed compared with particle swarm optimization (PSO) in designing a water pumping system with the lowest NPC.


Asunto(s)
Agua Potable , Modelos Teóricos , Reproducibilidad de los Resultados , Abastecimiento de Agua , Simulación por Computador
4.
Energies (Basel) ; 15(1): 5, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35910687

RESUMEN

In addition to zero-carbon generation, the plummeting cost of renewable energy sources (RES) is enabling the increased use of distributed-generation sources. Although the RES appear to be a cheaper source of energy, without the appropriate design of the RES with a true understanding of the nature of the load, they can be an unreliable and expensive source of energy. Limited research has been aimed at designing small-scale hybrid energy systems for irrigation pumping systems, and these studies did not quantify the water requirement, or in turn the energy required to supply the irrigation water. This paper provides a comprehensive feasibility analysis of an off-grid hybrid renewable energy system for the design of a water-pumping system for irrigation applications in Sudan. A systematic and holistic framework combined with a techno-economic optimization analysis for the planning and design of hybrid renewable energy systems for small-scale irrigation water-pumping systems is presented. Different hybridization cases of solar photovoltaic, wind turbine and battery storage at 12 different sites in Sudan are simulated, evaluated, and compared, considering the crop water requirement for different crops, the borehole depth, and the stochasticity of renewable energy resources. Soil, weather, and climatic data from 12 different sites in Sudan were used for the case studies, with the key aim to find the most robust and reliable solution with the lowest system cost. The results of the case studies suggest that the selection of the system is highly dependent on the cost, the volatility of the wind speed, solar radiation, and the size of the system; at present, hybridization is not the primary option at most of sites, with the exception of two. However, with the reduction in price of wind technology, the possibility of hybrid generation will rise.

5.
ISA Trans ; 129(Pt A): 424-435, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35153067

RESUMEN

The present research addresses a new optimum configuration for a Hybrid Renewable Energy System (HRES). The structure includes fuel cell (FC), wind turbine (WT), and photovoltaic (PV) and its auxiliaries including the electrolyzer and the H2 tank as the storage system. The primary mover in this study is the grid, while, the proposed HRES is used during energy deficiency from the grid side. The main target is to provide an optimum number of the HRES components to get the minimum loss of power supply probability (LOPSP) and Total Net Present Cost (TNPC). For achieving better optimal results, a Modified version of African vulture optimizer (IAVO) is proposed, validated, and used in the system. Final results are applied to a building in Ahvaz, Iran and they are put in comparison with different works of the studied works. The achievements indicated the primacy of the proposed system over the other algorithms.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA