Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 667
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Nano Lett ; 24(35): 10883-10891, 2024 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-39172995

RESUMEN

The development of electronic skin (e-skin) emulating the human skin's three essential functions (perception, protection, and thermoregulation) has great potential for human-machine interfaces and intelligent robotics. However, existing studies mainly focus on perception. This study presents a novel, eco-friendly, mechanically robust e-skin replicating human skin's three essential functions. The e-skin is composed of Ti3C2Tx MXene, polypyrrole, and bacterial cellulose nanofibers, where the MXene nanoflakes form the matrix, the bacterial cellulose nanofibers act as the filler, and the polypyrrole serves as a conductive "cross-linker". This design allows customization of the electrical conductivity, microarchitecture, and mechanical properties, integrating sensing (perception), EMI shielding (protection), and thermal management (thermoregulation). The optimal e-skin can effectively sense various motions (including minuscule artery pulses), achieve an EMI shielding efficiency of 63.32 dB at 78 µm thickness, and regulate temperature up to 129 °C in 30 s at 2.4 V, demonstrating its potential for smart robotics in complex scenarios.


Asunto(s)
Conductividad Eléctrica , Polímeros , Dispositivos Electrónicos Vestibles , Humanos , Polímeros/química , Pirroles/química , Nanofibras/química , Celulosa/química , Piel/química , Regulación de la Temperatura Corporal , Titanio/química , Robótica
2.
BMC Med ; 22(1): 36, 2024 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-38273340

RESUMEN

BACKGROUND: Continuous assessment and remote monitoring of cognitive function in individuals with mild cognitive impairment (MCI) enables tracking therapeutic effects and modifying treatment to achieve better clinical outcomes. While standardized neuropsychological tests are inconvenient for this purpose, wearable sensor technology collecting physiological and behavioral data looks promising to provide proxy measures of cognitive function. The objective of this study was to evaluate the predictive ability of digital physiological features, based on sensor data from wrist-worn wearables, in determining neuropsychological test scores in individuals with MCI. METHODS: We used the dataset collected from a 10-week single-arm clinical trial in older adults (50-70 years old) diagnosed with amnestic MCI (N = 30) who received a digitally delivered multidomain therapeutic intervention. Cognitive performance was assessed before and after the intervention using the Neuropsychological Test Battery (NTB) from which composite scores were calculated (executive function, processing speed, immediate memory, delayed memory and global cognition). The Empatica E4, a wrist-wearable medical-grade device, was used to collect physiological data including blood volume pulse, electrodermal activity, and skin temperature. We processed sensors' data and extracted a range of physiological features. We used interpolated NTB scores for 10-day intervals to test predictability of scores over short periods and to leverage the maximum of wearable data available. In addition, we used individually centered data which represents deviations from personal baselines. Supervised machine learning was used to train models predicting NTB scores from digital physiological features and demographics. Performance was evaluated using "leave-one-subject-out" and "leave-one-interval-out" cross-validation. RESULTS: The final sample included 96 aggregated data intervals from 17 individuals. In total, 106 digital physiological features were extracted. We found that physiological features, especially measures of heart rate variability, correlated most strongly to the executive function compared to other cognitive composites. The model predicted the actual executive function scores with correlation r = 0.69 and intra-individual changes in executive function scores with r = 0.61. CONCLUSIONS: Our findings demonstrated that wearable-based physiological measures, primarily HRV, have potential to be used for the continuous assessments of cognitive function in individuals with MCI.


Asunto(s)
Disfunción Cognitiva , Dispositivos Electrónicos Vestibles , Anciano , Humanos , Persona de Mediana Edad , Cognición , Disfunción Cognitiva/diagnóstico , Aprendizaje Automático , Pruebas Neuropsicológicas , Ensayos Clínicos como Asunto
3.
Chem Rec ; 24(7): e202300369, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38953343

RESUMEN

pH has been considered one of the paramount factors in bodily functions because most cellular tasks exclusively rely on precise pH values. In this context, the current techniques for pH sensing provide us with the futuristic insight to further design therapeutic and diagnostic tools. Thus, pH-sensing (electrochemically and optically) is rapidly evolving toward exciting new applications and expanding researchers' interests in many chemical contexts, especially in biomedical applications. The adaptation of cutting-edge technology is subsequently producing the modest form of these biosensors as wearable devices, which are providing us the opportunity to target the real-time collection of vital parameters, including pH for improved healthcare systems. The motif of this review is to provide insight into trending tech-based systems employed in real-time or in-vivo pH-responsive monitoring. Herein, we briefly go through the pH regulation in the human body to help the beginners and scientific community with quick background knowledge, recent advances in the field, and pH detection in real-time biological applications. In the end, we summarize our review by providing an outlook; challenges that need to be addressed, and prospective integration of various pH in vivo platforms with modern electronics that can open new avenues of cutting-edge techniques for disease diagnostics and prevention.


Asunto(s)
Técnicas Biosensibles , Concentración de Iones de Hidrógeno , Humanos , Dispositivos Electrónicos Vestibles , Técnicas Electroquímicas
4.
J Sleep Res ; : e14135, 2024 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-38212137

RESUMEN

This study aimed to determine whether objective sleep time is associated with the concentrations of various plasma cytokines in older adults with mild cognitive impairment (MCI). In total, 118 adults with MCI (66 women; mean age: 75.7 years) participated in this prospective cohort study. All participants were required to wear a wristband sensor for 7.8 days, on average, every 3 months for 1 year and undergo measurement of 27 plasma cytokines using multiplex immunoassays. After adjusting for potential confounders, the associations of total sleep time with cytokine concentrations were assessed by multiple linear regression analysis. The total sleep time was significantly correlated with plasma interleukin (IL)-9 and macrophage inflammatory protein (MIP)-1ß levels (r = 0.239, p = 0.009, and r = 0.242, p = 0.008, respectively). Moreover, these associations remained significant after adjusting for covariates, including demographic characteristics, lifestyle-related diseases, and apolipoprotein E status (ß = 0.272, 95% confidence interval: 0.095-0.448, p = 0.003, and ß = 0.27, 95% confidence interval: 0.092-0.449, p = 0.003, respectively). Thus, this study is the first to demonstrate the association between objective prolonged sleep and higher plasma IL-9 and MIP-1ß levels in older adults with MCI.

5.
Anal Bioanal Chem ; 416(7): 1635-1645, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38294529

RESUMEN

This study demonstrated for the first time that skin surface pH can be monitored in real-time, using a screen-printed wearable pH sensor, to evaluate the buffering capacity of the human skin. The screen-printed pH sensor was composed of a polyaniline-based pH-sensitive electrode and a nitrocellulose membrane-based liquid junction type of Ag/AgCl reference electrode. This sensor showed a reliable and reversible potentiometric response to pH with long-term potential stability. Intermittent monitoring of the buffering capacity of skin surface pH demonstrated the reliability of the proposed wearable pH sensor, which was comparable to that of a commercially available flat-tip pH sensor. We found that contact of the wearable pH sensor with the subject's skin via aqueous electrolyte solutions was necessary for the sensor to continuously monitor the skin surface pH while sustaining the natural buffer capacity of the human skin surface.


Asunto(s)
Dispositivos Electrónicos Vestibles , Humanos , Reproducibilidad de los Resultados , Piel , Electrodos , Concentración de Iones de Hidrógeno
6.
Macromol Rapid Commun ; : e2400279, 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38816757

RESUMEN

Hydrogel-based wearable sensors eventually experience dehydration, which negatively impacts their function, leading to decreased sensitivity. Monitoring the real-time water retention rate and sensing performance of wearable flexible sensors without dismantling them remains a significant difficulty. In this study, a molecule having aggregation-induced emission (AIE) properties in an aqueous environment has been developed and produced, which can combine with anionic guar gum and acrylic acid to create an AIE hydrogel. Wearable sensing electronic devices have the capability to track motion signals at various joints of the human body. Additionally, they can effectively and visually monitor dehydration status during extended periods of operation. The fluorescence intensity of the hydrogel is primarily influenced by the level of aggregation of luminous monomers inside the network. This level of aggregation is predominantly governed by the hydrogel's water retention rate. Hence, the extended duration of hydrogel dehydration can be manifested through alterations in their fluorescence characteristics, which are employed for strain sensing. This approach enables users to assess the water retention of hydrogels with greater efficiency, eliminating the requirement for disassembling them from the completed electrical gadget. In summary, the use of AIE-based fluorescent hydrogels will advance the progress of intelligent wearable electronics.

7.
Biomed Eng Online ; 23(1): 13, 2024 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-38297359

RESUMEN

BACKGROUND: Turning in place is a challenging motor task and is used as a brief assessment test of lower limb function and dynamic balance. This review aims to examine how research of instrumented analysis of turning in place is implemented. In addition to reporting the studied population, we covered acquisition systems, turn detection methods, quantitative parameters, and how these parameters are computed. METHODS: Following the development of a rigorous search strategy, the Web of Science and Scopus were systematically searched for studies involving the use of turning-in-place. From the selected articles, the study population, types of instruments used, turn detection method, and how the turning-in-place characteristics were calculated. RESULTS: Twenty-one papers met the inclusion criteria. The subject groups involved in the reviewed studies included young, middle-aged, and older adults, stroke, multiple sclerosis and Parkinson's disease patients. Inertial measurement units (16 studies) and motion camera systems (5 studies) were employed for gathering measurement data, force platforms were rarely used (2 studies). Two studies used commercial software for turn detection, six studies referenced previously published algorithms, two studies developed a custom detector, and eight studies did not provide any details about the turn detection method. The most frequently used parameters were mean angular velocity (14 cases, 7 studies), turn duration (13 cases, 13 studies), peak angular velocity (8 cases, 8 studies), jerkiness (6 cases, 5 studies) and freezing-of-gait ratios (5 cases, 5 studies). Angular velocities were derived from sensors placed on the lower back (7 cases, 4 studies), trunk (4 cases, 2 studies), and shank (2 cases, 1 study). The rest (9 cases, 8 studies) did not report sensor placement. Calculation of the freezing-of-gait ratio was based on the acceleration of the lower limbs in all cases. Jerkiness computation employed acceleration in the medio-lateral (4 cases) and antero-posterior (1 case) direction. One study did not reported any details about jerkiness computation. CONCLUSION: This review identified the capabilities of turning-in-place assessment in identifying movement differences between the various subject groups. The results, based on data acquired by inertial measurement units across studies, are comparable. A more in-depth analysis of tests developed for gait, which has been adopted in turning-in-place, is needed to examine their validity and accuracy.


Asunto(s)
Enfermedad de Parkinson , Accidente Cerebrovascular , Persona de Mediana Edad , Humanos , Anciano , Marcha , Movimiento , Pierna
8.
Sens Actuators B Chem ; 398: 134788, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38164440

RESUMEN

Online monitoring of prognostic biomarkers is critically important when diagnosing disorders and assessing individuals' health, especially for chronic and infectious diseases. Despite this, current diagnosis techniques are time-consuming, labor-intensive, and performed offline. In this context, developing wearable devices for continuous measurements of multiple biomarkers from body fluids has considerable advantages including availability, rapidity, convenience, and minimal invasiveness over the conventional painful and time-consuming tools. However, there is still a significant challenge in powering these devices over an extended period, especially for applications that require continuous and long-term health monitoring. Herein, a new freestanding, wearable, multifunctional microneedle-based extended gate field effect transistor biosensor is fabricated for online detection of multiple biomarkers from the interstitial fluid including sodium, calcium, potassium, and pH along with excellent electrical response, reversibility, and precision. In addition, a hybrid powering system of triboelectric nanogenerator and solar cell was developed for creating a freestanding, closed-loop platform for continuous charging of the device's battery and integrated with an Internet of Things technology to broadcast the measurements online, suggesting a stand-alone, stable multifunctional tool which paves the way for advanced practical personalized health monitoring and diagnosis.

9.
J Sports Sci ; 42(15): 1439-1452, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39259820

RESUMEN

The objective of this study was to evaluate the effect of skill modifications on head motion experienced during women's artistic gymnastics skills. Nine gymnasts (four beginner and five advanced) completed three trials of up to 24 skill progressions, each consisting of a skill and two progressive safety modifications. Gymnasts were instrumented with mouthpiece sensors embedded with an accelerometer and gyroscope collecting motion data at 200, 300, and 500 Hz during each skill performance. Peak-to-peak linear and rotational kinematics during contact phases and peak rotational kinematics during non-contact phases were computed. A mixed-effects model was used to compare differences in modification status nested within skill categories. Timer skills (i.e. drills that simulate performance of a gymnastics skill) resulted in the highest median ΔLA and ΔRA of all skill categories, and 132 skill performances exceeded 10 g ΔLA during a contact phase. Modifications were associated with significant reductions in head kinematics during contact phases of timers, floor skills, bar releases, and vault skills. Gymnasts can be exposed to direct and indirect head accelerations at magnitudes consistent with other youth contact sports, and common safety modifications may be effective at reducing head motion during contact and non-contact phases of gymnastics skills.


Asunto(s)
Aceleración , Gimnasia , Humanos , Gimnasia/fisiología , Fenómenos Biomecánicos , Femenino , Adolescente , Seguridad , Niño , Rotación , Acelerometría/instrumentación , Cabeza/fisiología , Estudios de Tiempo y Movimiento , Destreza Motora/fisiología , Equipo Deportivo , Movimientos de la Cabeza/fisiología
10.
Mikrochim Acta ; 191(6): 301, 2024 05 06.
Artículo en Inglés | MEDLINE | ID: mdl-38709350

RESUMEN

In the era of wearable electronic devices, which are quite popular nowadays, our research is focused on flexible as well as stretchable strain sensors, which are gaining humongous popularity because of recent advances in nanocomposites and their microstructures. Sensors that are stretchable and flexible based on graphene can be a prospective 'gateway' over the considerable biomedical speciality. The scientific community still faces a great problem in developing versatile and user-friendly graphene-based wearable strain sensors that satisfy the prerequisites of susceptible, ample range of sensing, and recoverable structural deformations. In this paper, we report the fabrication, development, detailed experimental analysis and electronic interfacing of a robust but simple PDMS/graphene/PDMS (PGP) multilayer strain sensor by drop casting conductive graphene ink as the sensing material onto a PDMS substrate. Electrochemical exfoliation of graphite leads to the production of abundant, fast and economical graphene. The PGP sensor selective to strain has a broad strain range of ⁓60%, with a maximum gauge factor of 850, detection of human physiological motion and personalized health monitoring, and the versatility to detect stretching with great sensitivity, recovery and repeatability. Additionally, recoverable structural deformation is demonstrated by the PGP strain sensors, and the sensor response is quite rapid for various ranges of frequency disturbances. The structural designation of graphene's overlap and crack structure is responsible for the resistance variations that give rise to the remarkable strain detection properties of this sensor. The comprehensive detection of resistance change resulting from different human body joints and physiological movements demonstrates that the PGP strain sensor is an effective choice for advanced biomedical and therapeutic electronic device utility.


Asunto(s)
Dimetilpolisiloxanos , Grafito , Dispositivos Electrónicos Vestibles , Grafito/química , Humanos , Dimetilpolisiloxanos/química , Movimiento
11.
Mikrochim Acta ; 191(7): 406, 2024 06 19.
Artículo en Inglés | MEDLINE | ID: mdl-38898359

RESUMEN

Microneedles, the miniaturized needles, which can pierce the skin with minimal invasiveness open up new possibilities for constructing personalized Point-of-Care (POC) diagnostic platforms. Recent advances in microneedle-based POC diagnostic systems, especially their successful implementation with wearable technologies, enable biochemical detection and physiological recordings in a user-friendly manner. This review presents an overview of the current advances in microneedle-based sensor devices, with emphasis on the biological basis of transdermal sensing, fabrication, and application of different types of microneedles, and a summary of microneedle devices based on various sensing strategies. It concludes with the challenges and future prospects of this swiftly growing field. The aim is to present a critical and thorough analysis of the state-of-the-art development of transdermal diagnostics and sensing devices based on microneedles, and to bridge the gap between microneedle technology and pragmatic applications.


Asunto(s)
Microinyecciones , Agujas , Humanos , Microinyecciones/instrumentación , Piel , Sistemas de Atención de Punto , Animales , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Dispositivos Electrónicos Vestibles
12.
Sensors (Basel) ; 24(2)2024 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-38276401

RESUMEN

Effective retraining of foot elevation and forward propulsion is a critical aspect of gait rehabilitation therapy after stroke, but valuable feedback to enhance these functions is often absent during home-based training. To enable feedback at home, this study assesses the validity of an inertial measurement unit (IMU) to measure the foot strike angle (FSA), and explores eight different kinematic parameters as potential indicators for forward propulsion. Twelve people with stroke performed walking trials while equipped with five IMUs and markers for optical motion analysis (the gold standard). The validity of the IMU-based FSA was assessed via Bland-Altman analysis, ICC, and the repeatability coefficient. Eight different kinematic parameters were compared to the forward propulsion via Pearson correlation. Analyses were performed on a stride-by-stride level and within-subject level. On a stride-by-stride level, the mean difference between the IMU-based FSA and OMCS-based FSA was 1.4 (95% confidence: -3.0; 5.9) degrees, with ICC = 0.97, and a repeatability coefficient of 5.3 degrees. The mean difference for the within-subject analysis was 1.5 (95% confidence: -1.0; 3.9) degrees, with a mean repeatability coefficient of 3.1 (SD: 2.0) degrees. Pearson's r value for all the studied parameters with forward propulsion were below 0.75 for the within-subject analysis, while on a stride-by-stride level the foot angle upon terminal contact and maximum foot angular velocity could be indicative for the peak forward propulsion. In conclusion, the FSA can accurately be assessed with an IMU on the foot in people with stroke during regular walking. However, no suitable kinematic indicator for forward propulsion was identified based on foot and shank movement that could be used for feedback in people with stroke.


Asunto(s)
Accidente Cerebrovascular , Dispositivos Electrónicos Vestibles , Humanos , Marcha , Caminata , Pie , Fenómenos Biomecánicos
13.
Sensors (Basel) ; 24(11)2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38894428

RESUMEN

Heart failure is a severe medical condition with an important worldwide incidence that occurs when the heart is unable to efficiently pump the patient's blood throughout the body. The monitoring of edema in the lower limbs is one of the most efficient ways to control the evolution of the condition. Impedance spectroscopy has been proposed as an efficient technique to monitor body volume in patients with heart failure. It is necessary to research new wearable devices for remote patient monitoring, which can be easily worn by patients in a continuous way. In this work, we design and implement new wearable textile electrodes for the monitoring of edema evolution in patients with heart failure. Impedance spectroscopy measurements were carried out in 5 healthy controls and 2 patients with heart failure using our wearable electrodes for 3 days. The results show the appropriateness of impedance spectroscopy and our wearable electrodes to monitor body volume evolution. Impedance spectroscopy is shown to be an efficient marker of the presence of edema in heart failure patients. Initial patient positive feedback was obtained for the use of the wearable device.


Asunto(s)
Espectroscopía Dieléctrica , Electrodos , Insuficiencia Cardíaca , Textiles , Dispositivos Electrónicos Vestibles , Humanos , Insuficiencia Cardíaca/fisiopatología , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Espectroscopía Dieléctrica/métodos , Espectroscopía Dieléctrica/instrumentación , Masculino , Femenino , Persona de Mediana Edad , Edema/diagnóstico , Anciano
14.
Sensors (Basel) ; 24(10)2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38793907

RESUMEN

(1) Background: This study evaluates the effectiveness of low-frequency repetitive transcranial magnetic stimulation (LF-rTMS) in improving gait in post-stroke hemiplegic patients, using wearable sensor technology for objective gait analysis. (2) Methods: A total of 72 stroke patients were randomized into control, sham stimulation, and LF-rTMS groups, with all receiving standard medical treatment. The LF-rTMS group underwent stimulation on the unaffected hemisphere for 6 weeks. Key metrics including the Fugl-Meyer Assessment Lower Extremity (FMA-LE), Berg Balance Scale (BBS), Modified Barthel Index (MBI), and gait parameters were measured before and after treatment. (3) Results: The LF-rTMS group showed significant improvements in the FMA-LE, BBS, MBI, and various gait parameters compared to the control and sham groups (p < 0.05). Specifically, the FMA-LE scores improved by an average of 5 points (from 15 ± 3 to 20 ± 2), the BBS scores increased by 8 points (from 35 ± 5 to 43 ± 4), the MBI scores rose by 10 points (from 50 ± 8 to 60 ± 7), and notable enhancements in gait parameters were observed: the gait cycle time was reduced from 2.05 ± 0.51 s to 1.02 ± 0.11 s, the stride length increased from 0.56 ± 0.04 m to 0.97 ± 0.08 m, and the walking speed improved from 35.95 ± 7.14 cm/s to 75.03 ± 11.36 cm/s (all p < 0.001). No adverse events were reported. The control and sham groups exhibited improvements but were not as significant. (4) Conclusions: LF-rTMS on the unaffected hemisphere significantly enhances lower-limb function, balance, and daily living activities in subacute stroke patients, with the gait parameters showing a notable improvement. Wearable sensor technology proves effective in providing detailed, objective gait analysis, offering valuable insights for clinical applications in stroke rehabilitation.


Asunto(s)
Marcha , Rehabilitación de Accidente Cerebrovascular , Accidente Cerebrovascular , Estimulación Magnética Transcraneal , Dispositivos Electrónicos Vestibles , Humanos , Masculino , Femenino , Estimulación Magnética Transcraneal/métodos , Estimulación Magnética Transcraneal/instrumentación , Persona de Mediana Edad , Accidente Cerebrovascular/fisiopatología , Accidente Cerebrovascular/terapia , Marcha/fisiología , Anciano , Rehabilitación de Accidente Cerebrovascular/instrumentación , Rehabilitación de Accidente Cerebrovascular/métodos , Análisis de la Marcha/métodos
15.
Sensors (Basel) ; 24(15)2024 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-39124101

RESUMEN

Clinical walk tests may not predict the development of frailty in healthy older adults. With advancements in wearable technology, it may be possible to predict the development of frailty using loading asymmetry parameters during clinical walk tests. This prospective cohort study aimed to test the hypothesis that increased limb loading asymmetry predicts frailty risk in community-living older adults. Sixty-three independently ambulant community-living adults aged ≥ 65 years were recruited, and forty-seven subjects completed the ten-month follow-up after baseline. Loading asymmetry index of net and regional (forefoot, midfoot, and rearfoot) plantar forces were collected using force sensing insoles during a 10 m walk test with their maximum speed. Development of frailty was defined if the participant progressed from baseline at least one grading group of frailty at the follow-up period using the Kihon Checklist. Fourteen subjects developed frailty during the follow-up period. Increased risk of frailty was associated with each 1% increase in loading asymmetry of net impulse (Odds ratio 1.153, 95%CI 1.001 to 1.329). Net impulse asymmetry significantly correlated with asymmetry of peak force in midfoot force. These results indicate the feasibility of measuring plantar forces of gait during clinical walking tests and underscore the potential of using load asymmetry as a tool to augment frailty risk assessment in community-dwelling older adults.


Asunto(s)
Fragilidad , Marcha , Vida Independiente , Humanos , Anciano , Masculino , Femenino , Marcha/fisiología , Fragilidad/fisiopatología , Fragilidad/diagnóstico , Anciano de 80 o más Años , Estudios Prospectivos , Zapatos , Anciano Frágil , Caminata/fisiología , Dispositivos Electrónicos Vestibles
16.
Sensors (Basel) ; 24(7)2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38610306

RESUMEN

Frontal and axial knee motion can affect the accuracy of the knee extension/flexion motion measurement using a wearable goniometer. The purpose of this study was to test the hypothesis that calibrating the goniometer on an individual's body would reduce errors in knee flexion angle during gait, compared to bench calibration. Ten young adults (23.2 ± 1.3 years) were enrolled. Knee flexion angles during gait were simultaneously assessed using a wearable goniometer sensor and an optical three-dimensional motion analysis system, and the absolute error (AE) between the two methods was calculated. The mean AE across a gait cycle was 2.4° (0.5°) for the on-body calibration, and the AE was acceptable (<5°) throughout a gait cycle (range: 1.5-3.8°). The mean AE for the on-bench calibration was 4.9° (3.4°) (range: 1.9-13.6°). Statistical parametric mapping (SPM) analysis revealed that the AE of the on-body calibration was significantly smaller than that of the on-bench calibration during 67-82% of the gait cycle. The results indicated that the on-body calibration of a goniometer sensor had acceptable and better validity compared to the on-bench calibration, especially for the swing phase of gait.


Asunto(s)
Dispositivos Ópticos , Dispositivos Electrónicos Vestibles , Adulto Joven , Humanos , Calibración , Articulación de la Rodilla , Marcha
17.
Sensors (Basel) ; 24(7)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38610427

RESUMEN

Flexibility in performing various movements like standing, walking, and turning is crucial for navigating dynamic environments in daily life. Individuals with essential tremor often experience movement difficulties that can affect these postural transitions, limiting mobility and independence. Yet, little research has examined the performance of postural transitions in people with essential tremor. Therefore, we assessed postural transition performance using two versions of the timed up and go test: the standard version and a more complex water-carry version. We examined the total duration of the standard and water-carry timed up and go in 15 people with and 15 people without essential tremor. We also compared the time taken for each phase (sit-to-stand phase, straight-line walk phase, stand-to-sit phase) and the turning velocity between groups. Our findings revealed decreased performance across all phases of standard and water-carry timed up and go assessments. Further, both ET and non-ET groups exhibited reduced performance during the water-carry timed up and go compared to the standard timed up and go. Evaluating specific phases of the timed up and go offers valuable insights into functional movement performance in essential tremor, permitting more tailored therapeutic interventions to improve functional performance during activities of daily living.


Asunto(s)
Temblor Esencial , Humanos , Actividades Cotidianas , Equilibrio Postural , Estudios de Tiempo y Movimiento , Agua
18.
Sensors (Basel) ; 24(5)2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38474972

RESUMEN

Salivary turbidity is a promising indicator for evaluating oral hygiene. This study proposed a wearable mouthguard-type sensor for continuous and unconstrained measurement of salivary turbidity. The sensor evaluated turbidity by measuring the light transmittance of saliva with an LED and a phototransistor sealed inside a double-layered mouthguard. The sensor was also embedded with a Bluetooth wireless module, enabling the wireless measurement of turbidity. The mouthguard materials (polyethylene terephthalate-glycol and ethylene-vinyl acetate) and the wavelength of the LED (405 nm) were experimentally determined to achieve high sensitivity in salivary turbidity measurement. The turbidity quantification characteristic of the proposed sensor was evaluated using a turbidity standard solution, and the sensor was capable of turbidity quantification over a wide dynamic range of 1-4000 FTU (formazine turbidity unit), including reported salivary turbidity (400-800 FTU). In vitro turbidity measurement using a saliva sample showed 553 FTU, which is equivalent to the same sample measured with a spectrophotometer (576 FTU). Moreover, in vivo experiments also showed results equivalent to that measured with a spectrophotometer, and wireless measurement of salivary turbidity was realized using the mouthguard-type sensor. Based on these results, the proposed mouthguard-type sensor has promising potential for the unconstrained continuous evaluation of oral hygiene.


Asunto(s)
Protectores Bucales , Dispositivos Electrónicos Vestibles , Higiene Bucal , Saliva
19.
Sensors (Basel) ; 24(10)2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38793899

RESUMEN

Metabolic syndrome poses a significant health challenge worldwide, prompting the need for comprehensive strategies integrating physical activity monitoring and energy expenditure. Wearable sensor devices have been used both for energy intake and energy expenditure (EE) estimation. Traditionally, sensors are attached to the hip or wrist. The primary aim of this research is to investigate the use of an eyeglass-mounted wearable energy intake sensor (Automatic Ingestion Monitor v2, AIM-2) for simultaneous recognition of physical activity (PAR) and estimation of steady-state EE as compared to a traditional hip-worn device. Study data were collected from six participants performing six structured activities, with the reference EE measured using indirect calorimetry (COSMED K5) and reported as metabolic equivalents of tasks (METs). Next, a novel deep convolutional neural network-based multitasking model (Multitasking-CNN) was developed for PAR and EE estimation. The Multitasking-CNN was trained with a two-step progressive training approach for higher accuracy, where in the first step the model for PAR was trained, and in the second step the model was fine-tuned for EE estimation. Finally, the performance of Multitasking-CNN on AIM-2 attached to eyeglasses was compared to the ActiGraph GT9X (AG) attached to the right hip. On the AIM-2 data, Multitasking-CNN achieved a maximum of 95% testing accuracy of PAR, a minimum of 0.59 METs mean square error (MSE), and 11% mean absolute percentage error (MAPE) in EE estimation. Conversely, on AG data, the Multitasking-CNN model achieved a maximum of 82% testing accuracy in PAR, a minimum of 0.73 METs MSE, and 13% MAPE in EE estimation. These results suggest the feasibility of using an eyeglass-mounted sensor for both PAR and EE estimation.


Asunto(s)
Metabolismo Energético , Ejercicio Físico , Anteojos , Redes Neurales de la Computación , Dispositivos Electrónicos Vestibles , Humanos , Metabolismo Energético/fisiología , Ejercicio Físico/fisiología , Adulto , Masculino , Calorimetría Indirecta/instrumentación , Calorimetría Indirecta/métodos , Femenino , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos
20.
Sensors (Basel) ; 24(11)2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38894140

RESUMEN

Nocturnal enuresis (NE) is involuntary bedwetting during sleep, typically appearing in young children. Despite the potential benefits of the long-term home monitoring of NE patients for research and treatment enhancement, this area remains underexplored. To address this, we propose NEcare, an in-home monitoring system that utilizes wearable devices and machine learning techniques. NEcare collects sensor data from an electrocardiogram, body impedance (BI), a three-axis accelerometer, and a three-axis gyroscope to examine bladder volume (BV), heart rate (HR), and periodic limb movements in sleep (PLMS). Additionally, it analyzes the collected NE patient data and supports NE moment estimation using heuristic rules and deep learning techniques. To demonstrate the feasibility of in-home monitoring for NE patients using our wearable system, we used our datasets from 30 in-hospital patients and 4 in-home patients. The results show that NEcare captures expected trends associated with NE occurrences, including BV increase, HR increase, and PLMS appearance. In addition, we studied the machine learning-based NE moment estimation, which could help relieve the burdens of NE patients and their families. Finally, we address the limitations and outline future research directions for the development of wearable systems for NE patients.


Asunto(s)
Enuresis Nocturna , Dispositivos Electrónicos Vestibles , Humanos , Enuresis Nocturna/fisiopatología , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Niño , Frecuencia Cardíaca/fisiología , Aprendizaje Automático , Masculino , Femenino , Electrocardiografía/métodos , Sueño/fisiología , Monitoreo Ambulatorio/instrumentación , Monitoreo Ambulatorio/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA