RESUMEN
BACKGROUND: In the ARTESiA trial (Apixaban for the Reduction of Thromboembolism in Patients With Device-Detected Subclinical Atrial Fibrillation), apixaban, compared with aspirin, reduced stroke or systemic embolism in patients with device-detected subclinical atrial fibrillation (SCAF). Clinical guidelines recommend considering SCAF episode duration when deciding whether to prescribe oral anticoagulation for this population. METHODS: We performed a retrospective cohort study in ARTESiA. Using Cox regression adjusted for CHA2DS2-VASc score and treatment allocation (apixaban or aspirin), we assessed frequency of SCAF episodes and duration of the longest SCAF episode in the 6 months before randomization as predictors of stroke risk and of apixaban treatment effect. RESULTS: Among 3986 patients with complete baseline SCAF data, 703 (17.6%) had no SCAF episode ≥6 minutes in the 6 months before enrollment. Among 3283 patients (82.4%) with ≥1 episode of SCAF ≥6 minutes in the 6 months before enrollment, 2542 (77.4%) had up to 5 episodes, and 741 (22.6%) had ≥6 episodes. The longest episode lasted <1 hour in 1030 patients (31.4%), 1 to <6 hours in 1421 patients (43.3%), and >6 hours in 832 patients (25.3%). Higher baseline SCAF frequency was not associated with increased risk of stroke or systemic embolism: 1.1% for 1 to 5 episodes versus 1.2%/patient-year for ≥6 episodes (adjusted hazard ratio, 0.89 [95% CI, 0.59-1.34]). In an exploratory analysis, patients with previous SCAF but no episode ≥6 minutes in the 6 months before enrollment had a lower risk of stroke or systemic embolism than patients with at least one episode during that period (0.5% versus 1.1%/patient-year; adjusted hazard ratio, 0.48 [95% CI, 0.27-0.85]). The frequency of SCAF did not modify the reduction in stroke or systemic embolism with apixaban (Pinteraction=0.1). The duration of the longest SCAF episode in the 6 months before enrollment was not associated with the risk of stroke or systemic embolism during follow-up (<1 hour: 1.0%/patient-year [reference]; 1-6 hours: 1.2%/patient-year [adjusted hazard ratio, 1.27 (95% CI, 0.85-1.90)]; >6 hours: 1.0%/patient-year [adjusted hazard ratio, 1.02 (95% CI, 0.63-1.66)]). SCAF duration did not modify the reduction in stroke or systemic embolism with apixaban (Ptrend=0.1). CONCLUSIONS: In ARTESiA, baseline SCAF frequency and longest episode duration were not associated with risk of stroke or systemic embolism and did not modify the effect of apixaban on reduction of stroke or systemic embolism. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01938248.
RESUMEN
The American Heart Association sponsored the first iteration of a scientific statement that addressed all aspects of cardiovascular implantable electronic device infection in 2010. Major advances in the prevention, diagnosis, and management of these infections have occurred since then, necessitating a scientific statement update. An 11-member writing group was identified and included recognized experts in cardiology and infectious diseases, with a career focus on cardiovascular infections. The group initially met in October 2022 to develop a scientific statement that was drafted with front-line clinicians in mind and focused on providing updated clinical information to enhance outcomes of patients with cardiovascular implantable electronic device infection. The current scientific statement highlights recent advances in prevention, diagnosis, and management, and how they may be incorporated in the complex care of patients with cardiovascular implantable electronic device infection.
Asunto(s)
Cardiología , Infecciones Cardiovasculares , Enfermedades Transmisibles , Desfibriladores Implantables , Endocarditis Bacteriana , Estados Unidos , Humanos , American Heart Association , Enfermedades Transmisibles/diagnóstico , Enfermedades Transmisibles/epidemiología , Enfermedades Transmisibles/terapia , Endocarditis Bacteriana/tratamiento farmacológico , Desfibriladores Implantables/efectos adversosRESUMEN
BACKGROUND: Left bundle branch area pacing (LBBAP) may be associated with greater improvement in left ventricular ejection fraction and reduction in death or heart failure hospitalization compared with biventricular pacing (BVP) in patients requiring cardiac resynchronization therapy. We sought to compare the occurrence of sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) and new-onset atrial fibrillation (AF) in patients undergoing BVP and LBBAP. METHODS: The I-CLAS study (International Collaborative LBBAP Study) included patients with left ventricular ejection fraction ≤35% who underwent BVP or LBBAP for cardiac resynchronization therapy between January 2018 and June 2022 at 15 centers. We performed propensity score-matched analysis of LBBAP and BVP in a 1:1 ratio. We assessed the incidence of VT/VF and new-onset AF among patients with no history of AF. Time to sustained VT/VF and time to new-onset AF was analyzed using the Cox proportional hazards survival model. RESULTS: Among 1778 patients undergoing cardiac resynchronization therapy (BVP, 981; LBBAP, 797), there were 1414 propensity score-matched patients (propensity score-matched BVP, 707; propensity score-matched LBBAP, 707). The occurrence of VT/VF was significantly lower with LBBAP compared with BVP (4.2% versus 9.3%; hazard ratio, 0.46 [95% CI, 0.29-0.74]; P<0.001). The incidence of VT storm (>3 episodes in 24 hours) was also significantly lower with LBBAP compared with BVP (0.8% versus 2.5%; P=0.013). Among 299 patients with cardiac resynchronization therapy pacemakers (BVP, 111; LBBAP, 188), VT/VF occurred in 8 patients in the BVP group versus none in the LBBAP group (7.2% versus 0%; P<0.001). In 1194 patients with no history of VT/VF or antiarrhythmic therapy (BVP, 591; LBBAP, 603), the occurrence of VT/VF was significantly lower with LBBAP than with BVP (3.2% versus 7.3%; hazard ratio, 0.46 [95% CI, 0.26-0.81]; P=0.007). Among patients with no history of AF (n=890), the occurrence of new-onset AF >30 s was significantly lower with LBBAP than with BVP (2.8% versus 6.6%; hazard ratio, 0.34 [95% CI, 0.16-0.73]; P=0.008). The incidence of AF lasting >24 hours was also significantly lower with LBBAP than with BVP (0.7% versus 2.9%; P=0.015). CONCLUSIONS: LBBAP was associated with a lower incidence of sustained VT/VF and new-onset AF compared with BVP. This difference remained significant after adjustment for differences in baseline characteristics between patients with BVP and LBBAP. Physiological resynchronization by LBBAP may be associated with lower risk of arrhythmias compared with BVP.
Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Taquicardia Ventricular , Humanos , Terapia de Resincronización Cardíaca/efectos adversos , Volumen Sistólico , Función Ventricular Izquierda , Resultado del Tratamiento , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/etiología , Taquicardia Ventricular/terapia , Fibrilación Ventricular/epidemiología , Fibrilación Ventricular/etiología , Fibrilación Ventricular/terapia , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , ElectrocardiografíaRESUMEN
BACKGROUND: Device-detected atrial fibrillation (also known as subclinical atrial fibrillation or atrial high-rate episodes) is a common finding in patients with an implanted cardiac rhythm device and is associated with an increased risk of ischemic stroke. Whether oral anticoagulation is effective and safe in this patient population is unclear. METHODS: We performed a systematic review of MEDLINE and Embase for randomized trials comparing oral anticoagulation with antiplatelet or no antithrombotic therapy in adults with device-detected atrial fibrillation recorded by a pacemaker, implantable cardioverter defibrillator, cardiac resynchronization therapy device, or implanted cardiac monitor. We used random-effects models for meta-analysis and rated the quality of evidence using the Grading of Recommendations Assessment, Development and Evaluation framework (GRADE). The review was preregistered (PROSPERO CRD42023463212). RESULTS: From 785 citations, we identified 2 randomized trials with relevant clinical outcome data: NOAH-AFNET 6 (Non-Vitamin K Antagonist Oral Anticoagulants in Patients With Atrial High Rate Episodes; 2536 participants) evaluated edoxaban, and ARTESiA (Apixaban for the Reduction of Thrombo-Embolism in Patients With Device-Detected Sub-Clinical Atrial Fibrillation; 4012 participants) evaluated apixaban. Meta-analysis demonstrated that oral anticoagulation with these agents reduced ischemic stroke (relative risk [RR], 0.68 [95% CI, 0.50-0.92]; high-quality evidence). The results from the 2 trials were consistent (I2 statistic for heterogeneity=0%). Oral anticoagulation also reduced a composite of cardiovascular death, all-cause stroke, peripheral arterial embolism, myocardial infarction, or pulmonary embolism (RR, 0.85 [95% CI, 0.73-0.99]; I2=0%; moderate-quality evidence). There was no reduction in cardiovascular death (RR, 0.95 [95% CI, 0.76-1.17]; I2=0%; moderate-quality evidence) or all-cause mortality (RR, 1.08 [95% CI, 0.96-1.21]; I2=0%; moderate-quality evidence). Oral anticoagulation increased major bleeding (RR, 1.62 [95% CI, 1.05-2.50]; I²=61%; high-quality evidence). CONCLUSIONS: The results of the NOAH-AFNET 6 and ARTESiA trials are consistent with each other. Meta-analysis of these 2 large randomized trials provides high-quality evidence that oral anticoagulation with edoxaban or apixaban reduces the risk of stroke in patients with device-detected atrial fibrillation and increases the risk of major bleeding.
Asunto(s)
Anticoagulantes , Fibrilación Atrial , Embolia , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Administración Oral , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Embolia/etiología , Hemorragia/prevención & control , Piridinas , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/prevención & control , Tiazoles , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como AsuntoRESUMEN
The rapid technological advancements in cardiac implantable electronic devices such as pacemakers, implantable cardioverter defibrillators, and loop recorders, coupled with a rise in the number of patients with these devices, necessitate an updated clinical framework for periprocedural management. The introduction of leadless pacemakers, subcutaneous and extravascular defibrillators, and novel device communication protocols underscores the imperative for clinical updates. This scientific statement provides an inclusive framework for the periprocedural management of patients with these devices, encompassing the planning phase, procedure, and subsequent care coordinated with the primary device managing clinic. Expert contributions from anesthesiologists, cardiac electrophysiologists, and cardiac nurses are consolidated to appraise current evidence, offer patient and health system management strategies, and highlight key areas for future research. The statement, pertinent to a wide range of health care professionals, underscores the importance of quality care pathways for patient safety, optimal device function, and minimization of hemodynamic disturbances or arrhythmias during procedures. Our primary objective is to deliver quality care to the expanding patient cohort with cardiac implanted electronic devices, offering direction in the era of evolving technologies and laying a foundation for sustained education and practice enhancement.
Asunto(s)
American Heart Association , Desfibriladores Implantables , Marcapaso Artificial , Atención Perioperativa , Humanos , Desfibriladores Implantables/normas , Estados Unidos , Atención Perioperativa/normas , Atención Perioperativa/métodos , Grupo de Atención al Paciente , Arritmias Cardíacas/terapiaRESUMEN
BACKGROUND: Black Americans have a higher risk of nonischemic cardiomyopathy (NICM) than White Americans. We aimed to evaluate differences in the risk of tachyarrhythmias among patients with an implantable cardioverter-defibrillator (ICD). METHODS: The study population comprised 3895 ICD recipients in the United States enrolled in primary prevention ICD trials. Outcome measures included ventricular tachyarrhythmia (VTA), atrial tachyarrhythmia (ATA), ICD therapies, VTA burden (using Andersen-Gill recurrent event analysis), death, and the predicted benefit of the ICD. All events were adjudicated blindly. Outcomes were compared between self-reported Black patients versus White patients with cardiomyopathy (ischemic and NICM). RESULTS: Black patients were more likely to be female (35% versus 22%) and younger (57±12 versus 62±12 years) with a higher frequency of comorbidities. In NICM, Black patients had a higher rate of first VTA, fast VTA, ATA, and appropriate and inappropriate ICD therapy (VTA ≥170 bpm, 32% versus 20%; VTA ≥200 bpm, 22% versus 14%; ATA, 25% versus 12%; appropriate therapy, 30% versus 20%; and inappropriate therapy, 25% versus 11%; P<0.001 for all). Multivariable analysis showed that Black patients with NICM experienced a higher risk of all types of arrhythmia or ICD therapy (VTA ≥170 bpm, hazard ratio [HR] 1.71; VTA ≥200 bpm, HR 1.58; ATA, HR 1.87; appropriate therapy, HR 1.62; inappropriate therapy, HR 1.86; P≤0.01 for all), higher burden of tachyarrhythmias or therapies (VTA, HR 1.84; appropriate therapy, HR 1.84; P<0.001 for both), and a higher risk of death (HR 1.92; P=0.014). In contrast, in ischemic cardiomyopathy, the risk of all types of tachyarrhythmia, ICD therapy, or death was similar between Black patients and White patients. Both Black patients and White patients derived a significant and similar benefit from ICD implantation. CONCLUSIONS: Among patients with NICM with an ICD for primary prevention, Black patients compared with White patients had a high risk and burden of VTA, ATA, and ICD therapies with a lower survival rate. Nevertheless, the overall benefit of the ICD was maintained and was similar to that of White patients.
Asunto(s)
Cardiomiopatías , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Femenino , Estados Unidos/epidemiología , Masculino , Blanco , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Factores de Riesgo , Arritmias Cardíacas , Taquicardia Ventricular/terapia , Taquicardia Ventricular/epidemiología , Prevención PrimariaRESUMEN
BACKGROUND: Treatment options for high-risk Brugada syndrome (BrS) with recurrent ventricular fibrillation (VF) are limited. Catheter ablation is increasingly performed but a large study with long-term outcome data is lacking. We report the results of the multicenter, international BRAVO (Brugada Ablation of VF Substrate Ongoing Registry) for treatment of high-risk symptomatic BrS. METHODS: We enrolled 159 patients (median age 42 years; 156 male) with BrS and spontaneous VF in BRAVO; 43 (27%) of them had BrS and early repolarization pattern. All but 5 had an implantable cardioverter-defibrillator for cardiac arrest (n=125) or syncope (n=34). A total of 140 (88%) had experienced numerous implantable cardioverter-defibrillator shocks for spontaneous VF before ablation. All patients underwent a percutaneous epicardial substrate ablation with electroanatomical mapping except for 8 who underwent open-thoracotomy ablation. RESULTS: In all patients, VF/BrS substrates were recorded in the epicardial surface of the right ventricular outflow tract; 45 (29%) patients also had an arrhythmic substrate in the inferior right ventricular epicardium and 3 in the posterior left ventricular epicardium. After a single ablation procedure, 128 of 159 (81%) patients remained free of VF recurrence; this number increased to 153 (96%) after a repeated procedure (mean 1.2±0.5 procedures; median=1), with a mean follow-up period of 48±29 months from the last ablation. VF burden and frequency of shocks decreased significantly from 1.1±2.1 per month before ablation to 0.003±0.14 per month after the last ablation (P<0.0001). The Kaplan-Meier VF-free survival beyond 5 years after the last ablation was 95%. The only variable associated with a VF-free outcome in multivariable analysis was normalization of the type 1 Brugada ECG, both with and without sodium-channel blockade, after the ablation (hazard ratio, 0.078 [95% CI, 0.008 to 0.753]; P=0.0274). There were no arrhythmic or cardiac deaths. Complications included hemopericardium in 4 (2.5%) patients. CONCLUSIONS: Ablation treatment is safe and highly effective in preventing VF recurrence in high-risk BrS. Prospective studies are needed to determine whether it can be an alternative treatment to implantable cardioverter-defibrillator implantation for selected patients with BrS. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04420078.
Asunto(s)
Síndrome de Brugada , Ablación por Catéter , Desfibriladores Implantables , Humanos , Masculino , Adulto , Fibrilación Ventricular , Electrocardiografía/métodos , Ventrículos Cardíacos , Síndrome de Brugada/cirugía , Síndrome de Brugada/complicaciones , Desfibriladores Implantables/efectos adversos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Sistema de RegistrosRESUMEN
BACKGROUND: Benefit from cardiac resynchronization therapy (CRT) varies by QRS characteristics; individual randomized trials are underpowered to assess benefit for relatively small subgroups. METHODS: The authors analyzed patient-level data from pivotal CRT trials (MIRACLE [Multicenter InSync Randomized Clinical Evaluation], MIRACLE-ICD [Multicenter InSync ICD Randomized Clinical Evaluation], MIRACLE-ICD II [Multicenter InSync ICD Randomized Clinical Evaluation II], REVERSE [Resynchronization Reverses Remodeling in Systolic Left Ventricular Dysfunction], RAFT [Resynchronization-Defibrillation for Ambulatory Heart Failure], BLOCK-HF [Biventricular Versus Right Ventricular Pacing in Heart Failure Patients with Atrioventricular Block], COMPANION [Comparison of Medical Therapy, Pacing and Defibrillation in Heart Failure], and MADIT-CRT [Multicenter Automatic Defibrillator Implantation Trial - Cardiac Resynchronization Therapy]) using Bayesian Hierarchical Weibull survival regression models to assess CRT benefit by QRS morphology (left bundle branch block [LBBB], n=4549; right bundle branch block [RBBB], n=691; and intraventricular conduction delay [IVCD], n=1024) and duration (with 150-ms partition). The continuous relationship between QRS duration and CRT benefit was also examined within subgroups defined by QRS morphology. The primary end point was time to heart failure hospitalization (HFH) or death; a secondary end point was time to all-cause death. RESULTS: Of 6264 patients included, 25% were women, the median age was 66 [interquartile range, 58 to 73] years, and 61% received CRT (with or without an implantable cardioverter defibrillator). CRT was associated with an overall lower risk of HFH or death (hazard ratio [HR], 0.73 [credible interval (CrI), 0.65 to 0.84]), and in subgroups of patients with QRS ≥150 ms and either LBBB (HR, 0.56 [CrI, 0.48 to 0.66]) or IVCD (HR, 0.59 [CrI, 0.39 to 0.89]), but not RBBB (HR 0.97 [CrI, 0.68 to 1.34]; Pinteraction <0.001). No significant association for CRT with HFH or death was observed when QRS was <150 ms (regardless of QRS morphology) or in the presence of RBBB. Similar relationships were observed for all-cause death. CONCLUSIONS: CRT is associated with reduced HFH or death in patients with QRS ≥150 ms and LBBB or IVCD, but not for those with RBBB. Aggregating RBBB and IVCD into a single "non-LBBB" category when selecting patients for CRT should be reconsidered. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifiers: NCT00271154, NCT00251251, NCT00267098, and NCT00180271.
Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Femenino , Anciano , Masculino , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Bloqueo de Rama/complicaciones , Terapia de Resincronización Cardíaca/efectos adversos , Teorema de Bayes , Ensayos Clínicos Controlados Aleatorios como Asunto , Desfibriladores Implantables/efectos adversos , Resultado del Tratamiento , ElectrocardiografíaRESUMEN
BACKGROUND: Hypertrophic cardiomyopathy (HCM) can be associated with an abnormal exercise response. In adults with HCM, abnormal results on exercise stress testing are predictive of heart failure outcomes. Our goal was to determine whether an abnormal exercise response is associated with adverse outcomes in pediatric patients with HCM. METHODS: In an international cohort study including 20 centers, phenotype-positive patients with primary HCM who were <18 years of age at diagnosis were included. Abnormal exercise response was defined as a blunted blood pressure response and new or worsened ST- or T-wave segment changes or complex ventricular ectopy. Sudden cardiac death (SCD) events were defined as a composite of SCD and aborted sudden cardiac arrest. Using Kaplan-Meier survival, competing outcomes, and Cox regression analyses, we analyzed the association of abnormal exercise test results with transplant and SCD event-free survival. RESULTS: Of 724 eligible patients, 630 underwent at least 1 exercise test. There were no major differences in clinical characteristics between those with or without an exercise test. The median age at exercise testing was 13.8 years (interquartile range, 4.7 years); 78% were male and 39% were receiving beta-blockers. A total of 175 (28%) had abnormal test results. Patients with abnormal test results had more severe septal hypertrophy, higher left atrial diameter z scores, higher resting left ventricular outflow tract gradient, and higher frequency of myectomy compared with participants with normal test results (P<0.05). Compared with normal test results, abnormal test results were independently associated with lower 5-year transplant-free survival (97% versus 88%, respectively; P=0.005). Patients with exercise-induced ischemia were most likely to experience all-cause death or transplant (hazard ratio, 4.86 [95% CI, 1.69-13.99]), followed by those with an abnormal blood pressure response (hazard ratio, 3.19 [95% CI, 1.32-7.71]). Exercise-induced ischemia was also independently associated with lower SCD event-free survival (hazard ratio, 3.32 [95% CI, 1.27-8.70]). Exercise-induced ectopy was not associated with survival. CONCLUSIONS: Exercise abnormalities are common in childhood HCM. An abnormal exercise test result was independently associated with lower transplant-free survival, especially in those with an ischemic or abnormal blood pressure response with exercise. Exercise-induced ischemia was also independently associated with SCD events. These findings argue for routine exercise testing in childhood HCM as part of ongoing risk assessment.
Asunto(s)
Cardiomiopatía Hipertrófica , Prueba de Esfuerzo , Masculino , Femenino , Humanos , Estudios de Cohortes , Prevalencia , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico , Cardiomiopatía Hipertrófica/cirugía , Arritmias Cardíacas/etiología , Factores de RiesgoRESUMEN
The notion that the risk of sudden cardiac death (SCD) in patients with heart failure (HF) is declining seems to be gaining traction. Numerous editorials and commentaries have suggested that SCD, specifically arrhythmic SCD, is no longer a significant risk for patients with HF on guideline-directed medical therapy. In this review, we question whether the risk of SCD has indeed declined in HF trials and in the real world. We also explore whether, despite relative risk reductions, the residual SCD risk after guideline-directed medical therapy still suggests a need for implantable cardioverter defibrillator therapy. Among our arguments is that SCD has not decreased in HF trials, nor in the real world. Moreover, we argue that data from HF trials, which have not adhered to guideline-directed device therapy, do not obviate or justify delays to implantable cardioverter defibrillator therapy. In this context, we underline the challenges of translating the findings of HF randomized, controlled trials of guideline-directed medical therapy to the real world. We also make the case for HF trials that adhere to current guideline-directed device therapy so that we can better understand the role of implantable cardioverter defibrillators in chronic HF.
Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/terapia , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & controlRESUMEN
BACKGROUND: Ventricular arrhythmia is an important cause of mortality in patients with ischemic left ventricular dysfunction. Revascularization with coronary artery bypass graft or percutaneous coronary intervention is often recommended for these patients before implantation of a cardiac defibrillator because it is assumed that this may reduce the incidence of fatal and potentially fatal ventricular arrhythmias, although this premise has not been evaluated in a randomized trial to date. METHODS: Patients with severe left ventricular dysfunction, extensive coronary disease, and viable myocardium were randomly assigned to receive either percutaneous coronary intervention (PCI) plus optimal medical and device therapy (OMT) or OMT alone. The composite primary outcome was all-cause death or aborted sudden death (defined as an appropriate implantable cardioverter defibrillator therapy or a resuscitated cardiac arrest) at a minimum of 24 months, analyzed as time to first event on an intention-to-treat basis. Secondary outcomes included cardiovascular death or aborted sudden death, appropriate implantable cardioverter defibrillator (ICD) therapy or sustained ventricular arrhythmia, and number of appropriate ICD therapies. RESULTS: Between August 28, 2013, and March 19, 2020, 700 patients were enrolled across 40 centers in the United Kingdom. A total of 347 patients were assigned to the PCI+OMT group and 353 to the OMT alone group. The mean age of participants was 69 years; 88% were male; 56% had hypertension; 41% had diabetes; and 53% had a clinical history of myocardial infarction. The median left ventricular ejection fraction was 28%; 53.1% had an implantable defibrillator inserted before randomization or during follow-up. All-cause death or aborted sudden death occurred in 144 patients (41.6%) in the PCI group and 142 patients (40.2%) in the OMT group (hazard ratio, 1.03 [95% CI, 0.82-1.30]; P=0.80). There was no between-group difference in the occurrence of any of the secondary outcomes. CONCLUSIONS: PCI was not associated with a reduction in all-cause mortality or aborted sudden death. In patients with ischemic cardiomyopathy, PCI is not beneficial solely for the purpose of reducing potentially fatal ventricular arrhythmias. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01920048.
Asunto(s)
Desfibriladores Implantables , Disfunción Ventricular Izquierda , Humanos , Masculino , Anciano , Femenino , Volumen Sistólico , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Función Ventricular Izquierda , Arritmias Cardíacas/etiología , Disfunción Ventricular Izquierda/etiología , Desfibriladores Implantables/efectos adversos , Resultado del TratamientoRESUMEN
INTRODUCTION: Despite advancements in implantable cardioverter-defibrillator (ICD) technology, sudden cardiac death (SCD) remains a persistent public health concern. Chagas disease (ChD), prevalent in Brazil, is associated with increased ventricular tachycardia (VT) and ventricular fibrillation (VF) events and SCD compared to other cardiomyopathies. METHODS: This retrospective observational study included patients who received ICDs between October 2007 and December 2018. The study aims to assess whether mortality and VT/VF events decreased in patients who received ICDs during different time periods (2007-2010, 2011-2014, and 2015-2018). Additionally, it seeks to compare the prognosis of ChD patients with non-ChD patients. Time periods were chosen based on the establishment of the Arrhythmia Service in 2011. The primary outcome was overall mortality, assessed across the entire sample and the three periods. Secondary outcomes included VT/VF events and the combined outcome of death or VT/VF. RESULTS: Of the 885 patients included, 31% had ChD. Among them, 28% died, 14% had VT/VF events, and 37% experienced death and/or VT/VF. Analysis revealed that period 3 (2015-2018) was associated with better death-free survival (p = .007). ChD was the only variable associated with a higher rate of VT/VF events (p < .001) and the combined outcome (p = .009). CONCLUSION: Mortality and combined outcome rates decreased gradually for ICD patients during the periods 2011-2014 and 2015-2018 compared to the initial period (2007-2010). ChD was associated with higher VT/VF events in ICD patients, only in the first two periods.
Asunto(s)
Cardiomiopatías , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Cardiomiopatías/etiología , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Desfibriladores Implantables/efectos adversos , América Latina , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/etiología , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/terapia , Fibrilación Ventricular/etiología , Estudios RetrospectivosRESUMEN
BACKGROUND: Remote monitoring (RM) of pacemakers and implantable cardioverter-defibrillators (ICDs) reduces morbidity and mortality. However, many patients are not adherent to RM. OBJECTIVE: To test the effect of informational postcards on RM adherence. DESIGN/PATIENTS: Stepped-wedge randomized controlled trial among Veterans with pacemakers and ICDs. INTERVENTION: In wave 1, Veterans who had sent at least 1 transmission within the past 2 years but had become non-adherent were randomly assigned to receive a postcard or no postcard. Those receiving postcards were randomized to 1 of 2 messages: (1) a"warning" postcard describing risks of non-adherence or (2) an "encouraging" postcard describing benefits of adherence. In wave 2, Veterans who had either not received a postcard in wave 1 or had since become non-adherent were mailed a postcard (again, randomized to 1 of 2 messages). Patients who did not send an RM transmission within 1 month were mailed a second, identical postcard. MAIN MEASURES: Transmission within 70 days. KEY RESULTS: Overall, 6351 Veterans were included. In waves 1 and 2, postcards were mailed to 5657 Veterans (2821 "warning" messages and 2836 "encouraging" messages). Wave 1 included 2178 Veterans as controls (i.e., not mailed a postcard), some of whom received a postcard in wave 2 if they remained non-adherent. In wave 2, 3473 postcards were sent. Of the 5657 patients mailed a postcard, 2756 (48.7%) sent an RM transmission within 70 days, compared to 530 (24.3%) of 2178 controls (absolute difference 24.4%, 95% confidence interval [CI] 22.2%, 26.6%). Of those who sent a transmission, 71.8% did so after the first postcard. Transmission rates at 70 days did not significantly differ between "warning" and "encouraging" messages (odds ratio 1.04, 95% CI 0.92, 1.18). CONCLUSIONS: Informational postcards led to a 24.4% absolute increase in adherence at 70 days among Veterans with pacemakers and ICDs who were non-adherent to RM.
Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Veteranos , HumanosRESUMEN
AIMS: To predict worsening heart failure hospitalizations (WHFHs) in patients with implantable defibrillators and remote monitoring, the HeartInsight algorithm (Biotronik, Berlin, Germany) calculates a heart failure (HF) score combining seven physiologic parameters: 24â h heart rate (HR), nocturnal HR, HR variability, atrial tachyarrhythmia, ventricular extrasystoles, patient activity, and thoracic impedance. We compared temporal trends of the HF score and its components 12 weeks before a WHFH with 12-week trends in patients without WHFH, to assess whether trends indicate deteriorating HF regardless of alert status. METHODS AND RESULTS: Data from nine clinical trials were pooled, including 2050 patients with a defibrillator capable of atrial sensing, ejection fraction ≤ 35%, NYHA class II/III, no long-standing atrial fibrillation, and 369 WHFH from 259 patients. The mean HF score was higher in the WHFH group than in the no WHFH group (42.3 ± 26.1 vs. 30.7 ± 20.6, P < 0.001) already at the beginning of 12 weeks. The mean HF score further increased to 51.6 ± 26.8 until WHFH (+22% vs. no WHFH group, P = 0.003). As compared to the no WHFH group, the algorithm components either were already higher 12 weeks before WHFH (24â h HR, HR variability, thoracic impedance) or significantly increased until WHFH (nocturnal HR, atrial tachyarrhythmia, ventricular extrasystoles, patient activity). CONCLUSION: The HF score was significantly higher at, and further increased during 12 weeks before WHFH, as compared to the no WHFH group, with seven components showing different behaviour and contribution. Temporal trends of HF score may serve as a quantitative estimate of HF condition and evolution prior to WHFH.
Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Taquicardia Ventricular , Humanos , Hospitalización , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Complejos Cardíacos PrematurosRESUMEN
BACKGROUND: Implantable cardioverter defibrillators (ICD), as a gold and standard treatment for fatal cardiac arrhythmia, may lead to some physical and psychological problems for the patients. Therefore, performing some interventions to reduce or eliminate these issues is crucial. This study aimed to determine the effect of virtual interactive nurse-led support group intervention on fatigue, shock anxiety, and acceptance of ICD patients. METHODS: This is a clinical trial study on 72 patients with ICD. They were randomly allocated to the intervention (n = 36) and control (n = 36) groups. A virtual interactive nurse-led support group intervention through WhasApp was performed for one month. Multidimensional fatigue inventory, Florida Shock Anxiety Scale, and Florida Patient Acceptance Scale were used. Data were analyzed to perform the analysis of data through SPSS, using independent and paired-t test, Mann-Whitney U test, Wilcoxon test, and ANCOVA. RESULTS: Before the intervention, no significant difference was observed between the two groups with regard to fatigue, shock anxiety, and ICD acceptance. However, after the intervention, a significant difference was found between the two groups with regard to fatigue, shock anxiety, and ICD acceptance (P < 0.05). CONCLUSION: This study showed that virtual interactive nurse-led support group intervention reduced fatigue and shock anxiety and improved the ICD acceptance. PRACTICE IMPLICATIONS: This flexible, accessible, and interactive nurse-led support group intervention is suggested to be used for ICD patients. TRIAL REGISTRATION: This trial was registered and approved by Iranian Registry of Clinical Trials (Trial Id: 60,738, date: (24/02/2022). ( https://www.irct.ir/trial/60738 ).
Asunto(s)
Desfibriladores Implantables , Humanos , Desfibriladores Implantables/psicología , Irán , Rol de la Enfermera , Calidad de Vida/psicología , Ansiedad/diagnóstico , Ansiedad/prevención & control , Grupos de Autoayuda , FatigaRESUMEN
BACKGROUND: Patients ≥80 with implantable cardioverter-defibrillators (ICDs) have high rates of hospitalization and mortality, yet few have documented advance directives. We sought to determine the prevalence of advance directives in adults ≥80 years with ICDs, focusing on those with frailty and cognitive impairment. METHODS: Prospective cohort study (July 2016-May 2019) in an electrophysiology clinic. Presence of advance directives (health care proxies [HCP] and living wills [LW], or medical orders for life-sustaining treatment [MOLST]) was determined by medical record review. Frailty and cognitive impairment were screened using 4-m gait speed and Mini-Cog. RESULTS: 77 Veterans were evaluated. Mean age 84 years, 100% male, 70% frail. Overall, 52 (68%) had an HCP and 37 (48%) had a LW/MOLST. Of 67 with cognitive testing, 36% were impaired. HCP documentation was similar among frail and non-frail (69% vs. 65%). LW/MOLST was more prevalent among frail versus non-frail (52% vs. 39%). There was no difference in HCP documentation by cognitive status (67%). A LW/MOLST was more frequent for cognitively impaired versus non-impaired (50% vs. 42%). Among 19 Veterans who were frail and cognitively impaired, 14 (74%) had an HCP and 11 (58%) had a LW/MOLST. CONCLUSIONS: Most Veterans had a documented advance directive, but a significant minority did not. Simple frailty and cognitive screening tools can rapidly identify patients for whom discussion of advance directives is especially important.
Asunto(s)
Directivas Anticipadas , Desfibriladores Implantables , Humanos , Masculino , Femenino , Anciano de 80 o más Años , Estudios Prospectivos , Disfunción Cognitiva , FragilidadRESUMEN
BACKGROUND: Sudden cardiac death (SCD) risk markers are needed in Chagas cardiomyopathy (CC). Action potential duration restitution (APDR) dynamics is capable of extracting information on cardiac regional heterogeneity. This study intends to develop a patient-specific variables-based algorithm to predict SCD in the low-intermediate subgroups of the Rassi risk score. METHODS: Cross-sectional study of patients who underwent 24-h Holter for research purposes between January 1992 and February 2017. From 4-h ECG segment, RR series were generated and APDR dynamics metrics were calculated. Classification tree and sensitivity analysis were applied. As outcomes, SCD, SCD-free and non-cardiovascular death and 34 variables were included. RESULTS: Two hundred twenty-one (129 in the group SCD-free, 80 in the SCD group and 12 non-cardiovascular death group) were analyzed. In the groups with and without SCD (209 patients), the median age was 66 years, 52% were female, the cardiac involvement was mild to moderate in 72% with a Rassi point median of 8 (IQ: 3 to 11). The SCD group had more ventricular remodeling and more ventricular electrical instability. The occurrence of a %beats QTend/TendQ ratio > 1 (AUC, 0.96 (95% CI 0.89-0.98) present in more than 56.7% of the 4-h ECG segments was sufficient to identify patients of the SCD subgroup. Variables representing different stages of CC were also relevant in the model. CONCLUSION: It is possible to use APDR dynamics as an adjuvant in the SCD risk assessment in a subgroup of patients with a high risk of SCD and a very low risk of non-CV death with high power of discrimination.
Asunto(s)
Cardiomiopatía Chagásica , Desfibriladores Implantables , Humanos , Anciano , Volumen Sistólico/fisiología , Función Ventricular Izquierda , Cardiomiopatía Chagásica/complicaciones , Estudios Transversales , Muerte Súbita Cardíaca/epidemiología , Factores de Riesgo , Medición de RiesgoRESUMEN
Implantable cardioverter-defibrillators (ICDs) have revolutionized the prognosis for patients at elevated risk of ventricular tachyarrhythmias. For safety, defibrillation should be effective with a minimum of 10 J below the device's maximum energy. While modern ICDs rarely deliver ineffective shocks in primary prevention, the surge in managing severe heart failure patients has led to an increased number of patients with high defibrillation thresholds (DFTs). This article elucidates the potential causes of high DFT, including clinical factors, lead and device placement, the presence of a Left Ventricular Assist Device (LVAD), prolonged ventricular arrhythmias, shock vectors, waveform tilt, medications, and manufacturer-specific options. We also detail management strategies, highlighting alternative shock coil placements, practical recommendations, and case studies from our institution. Our management algorithm suggests addressing preventable causes, re-evaluating coil positions, considering non-invasive system modifications, upgrading to a higher-capacity device, and adding extra coil(s).
Asunto(s)
Desfibriladores Implantables , Corazón Auxiliar , Humanos , Arritmias Cardíacas , Pronóstico , Cardioversión Eléctrica , Fibrilación Ventricular/terapiaRESUMEN
Heart failure (HF) is a complex, heterogeneous syndrome with several comorbidities, often life-threatening and requires urgent therapy. In HF, metabolic alterations that can be assessed using comprehensive plasma, and tissue profiling will help establish new biomarkers and therapeutic targets. Metabolomic analysis of sudden death in HF cases remains unresolved. We prospectively evaluated 19 patients who underwent implantable cardioverter defibrillator (ICD) placement for the primary prevention of sudden cardiac death (SCD). Metabolomic analysis was performed using plasma samples before ICD implantation. Ventricular arrhythmia (VA)/SCD was defined as VA with an appropriate ICD therapy or SCD. During a median follow-up of 29 months (range, 13-35 months), four patients developed VA and one patient developed SCD. Using metabolomic analysis, arginine, lysine, and valine were significantly reduced in patients with VA/SCD (n = 5) compared with those without VA/SCD (n = 14). The molecules involved in energy metabolism might be associated with VA/SCD, thus requiring further investigation as a predictive value of metabolomic analysis of VA/SCD.
RESUMEN
BACKGROUND: Reducing anxiety about motor vehicle driving in patients receiving implantable cardioverter defibrillators and cardiac resynchronization therapy with defibrillators is important not only for improving quality of life but also for preventing vehicle collisions owing to driver distraction. This study aimed to clarify the driving-related anxiety of patients with these defibrillators and the factors that predict such anxiety. METHODS: We conducted a cross-sectional survey using a self-administered questionnaire of patients who had been driving a vehicle after device implantation at a general hospital between August 2018 and November 2019. RESULTS: The mean age was 60.8 ± 12.6 years. The reasons for implantation were primary prevention in 47 patients and secondary prevention in 30 patients. A total of 16 patients experienced anxiety about driving and 61 did not. Significantly more younger patients (mean age of 50.4 vs. 63.6 years, p < 0.001) and those with implantable cardioverter defibrillators had anxiety (100% vs. 73.8%, p = 0.02). Multivariable analysis indicated that age was the only independent factor that predicted driving-related anxiety (odds ratio, 0.937; 95% confidence interval, 0.883-0.993). CONCLUSIONS: Identifying and addressing driving-related anxiety in patients (particularly young patients) with defibrillators is important in preventing motor vehicle collisions and improving quality of life.