RESUMEN
Tricuspid valve disease is an often underrecognized clinical problem that is associated with significant morbidity and mortality. Unfortunately, patients will often present late in their disease course with severe right-sided heart failure, pulmonary hypertension, and life-limiting symptoms that have few durable treatment options. Traditionally, the only treatment for tricuspid valve disease has been medical therapy or surgery; however, there have been increasing interest and success with the use of transcatheter tricuspid valve therapies over the past several years to treat patients with previously limited therapeutic options. The tricuspid valve is complex anatomically, lying adjacent to important anatomic structures such as the right coronary artery and the atrioventricular node, and is the passageway for permanent pacemaker leads into the right ventricle. In addition, the mechanism of tricuspid pathology varies widely between patients, which can be due to primary, secondary, or a combination of causes, meaning that it is not possible for 1 type of device to be suitable for treatment of all cases of tricuspid valve disease. To best visualize the pathology, several modalities of advanced cardiac imaging are often required, including transthoracic echocardiography, transesophageal echocardiography, cardiac computed tomography, and cardiac magnetic resonance imaging, to best visualize the pathology. This detailed imaging provides important information for choosing the ideal transcatheter treatment options for patients with tricuspid valve disease, taking into account the need for the lifetime management of the patient. This review highlights the important background, anatomic considerations, therapeutic options, and future directions with regard to treatment of tricuspid valve disease.
Asunto(s)
American Heart Association , Válvula Tricúspide , Humanos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/patología , Estados Unidos , Enfermedades de las Válvulas Cardíacas/terapia , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/terapia , Implantación de Prótesis de Válvulas CardíacasRESUMEN
PURPOSE: Staphylococcus aureus prosthetic valve endocarditis (SAPVE) is a serious infection with high mortality. The main objective of this study was to identify factors associated with in-hospital mortality. METHODS: From January 2008 to December 2021, consecutive patients from a Spanish cohort of infective endocarditis with a definitive diagnosis of SAPVE were analyzed. RESULTS: During the study period, 219 cases of definitive SAPVE were diagnosed, which accounted for 16.7% of a total of 1309 cases of definitive prosthetic valve endocarditis (PVE). Patients presented advanced age and marked comorbidity. There was a higher incidence of persistent bacteremia, septic shock, stroke, and acute kidney injury than in cases of PVE caused by other microorganisms. Methicillin resistance was not associated with differences in clinical presentation, echocardiographic findings, or mortality. Only 50.6% of the patients with surgical indications (88 patients) underwent surgery. Overall, in-hospital mortality was 47.9%. The variables associated with in-hospital mortality were age (OR:1.03, 95% CI: 1.00-1.05; p = 0.016), heart failure (OR:2.86, 95% CI: 1.53-5.32; p = 0.001), acute kidney injury (OR:2.42, 95%CI:1.28-4.58; p = 0.006), stroke (OR:3.53, 95%CI:1.79-6.96; p < 0.001) and surgery indicated but not performed (OR:2.01, 95%CI:1.06-3.8; p = 0.030). On the other hand, the performance of surgery per se in patients with SAPVE, regardless of whether there was a surgical indication according to the guidelines, was not associated with a reduction in in-hospital mortality. CONCLUSIONS: SAPVE is characterized by high mortality, which is more marked in patients who present a surgical indication but do not undergo surgery.
Asunto(s)
Endocarditis Bacteriana , Prótesis Valvulares Cardíacas , Mortalidad Hospitalaria , Infecciones Relacionadas con Prótesis , Infecciones Estafilocócicas , Staphylococcus aureus , Humanos , Masculino , Femenino , Anciano , Infecciones Estafilocócicas/mortalidad , Infecciones Estafilocócicas/microbiología , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/mortalidad , Staphylococcus aureus/aislamiento & purificación , Persona de Mediana Edad , Prótesis Valvulares Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/microbiología , Pronóstico , Endocarditis Bacteriana/microbiología , Endocarditis Bacteriana/mortalidad , Endocarditis Bacteriana/cirugía , Endocarditis Bacteriana/diagnóstico , España/epidemiología , Anciano de 80 o más Años , Estudios Retrospectivos , Factores de Riesgo , Bacteriemia/microbiología , Bacteriemia/mortalidadRESUMEN
Preclinical testing using animal models is indispensable in cardiovascular research. However, the translation to clinical practice of these animal models is questionable since it is not always clear how representative they are. This systematic review intends to summarize the interspecies differences in the coagulation profile of animal models used in cardiovascular research. It aims to guide future research in choosing the optimal animal species. A literature search of PubMed, Embase, Web of Science (Core Collection) and Cochrane Library was performed using a search string that was well defined and not modified during the study. An overview of the search terms used in each database can be found in the appendix. Articles describing coagulation systems in large animals were included. We identified 30 eligible studies of which 15 were included. Compared to humans, sheep demonstrated a less active external pathway of coagulation. Sheep had a higher platelet count but the platelet activatability and response to biomaterials were lower. Both sheep and pigs displayed no big differences in the internal coagulation system compared to humans. Pigs showed results very similar to those of humans, with the exception of a higher platelet count and stronger platelet aggregation in pigs. Coagulation profiles of different species used for preclinical testing show strong variation. Adequate knowledge of these differences is key in the selection of the appropriate species for preclinical cardiovascular research. Future thrombogenicity research should compare sheep to pig in an identical experimental setup.
RESUMEN
Coatings with xenogenic materials, made of detonation nanodiamonds, provide additional strength and increase elasticity. A functionally developed surface of nanodiamonds makes it possible to apply antibiotics. Previous experiments show the stability of such coatings; however, studies on stability in the bloodstream and calcification of the material in natural conditions have yet to be conducted. Tritium-labeled nanodiamonds (negative and positive) were obtained by the tritium activation method and used to develop coatings for a pork aorta to analyze their stability in a pig's bloodstream using a radiotracer technique. A chitosan layer was applied from a solution of carbonic acid under high-pressure conditions to prevent calcification. The obtained materials were used to prepare a porcine conduit, which was surgically stitched inside the pig's aorta for four months. The aorta samples, including nanodiamond-coated and control samples, were analyzed for nanodiamond content and calcium, using the radiotracer and ICP-AES methods. A histological analysis of the materials was also performed. The obtained coatings illustrate a high in vivo stability and low levels of calcification for all types of nanodiamonds. Even though we did not use additional antibiotics in this case, the development of infection was not observed for negatively charged nanodiamonds, opening up prospects for their use in developing coatings.
Asunto(s)
Materiales Biocompatibles Revestidos , Nanodiamantes , Tritio , Animales , Nanodiamantes/química , Porcinos , Materiales Biocompatibles Revestidos/química , Tritio/química , Aorta , Bioprótesis , Quitosano/química , Prótesis Valvulares CardíacasRESUMEN
BACKGROUND: Permanent pacemaker implantation (PPI) is a common complication after transcatheter aortic valve implantation (TAVI). The cusp-overlap view (COV) was adopted to reduce PPI risk after TAVI with self-expandable valves (SEVs); however, the evidence remains scarce. We performed a systematic review with meta-analysis comparing COV and the standard coplanar view (CPV) technique to evaluate their effectiveness and safety. METHODS: Following the PRISMA statement, data were extracted from studies published by August 2022 and found in PubMed/MEDLINE, EMBASE, CENTRAL/CCTR, ClinicalTrials.gov, SciELO, LILACS, and Google Scholar. The primary outcome of interest was post-procedural PPI and the secondary outcomes were new left bundle branch block (LBBB), moderate/severe paravalvular leak (PVL), valve dislocation (pop-out); need of second transcatheter heart valve, 30-day mortality, stroke, conversion to surgery, coronary obstruction, implantation depth (mm), and post-TAVI mean gradients (mmHg). RESULTS: Eleven studies met our eligibility criteria and included 1464 patients in the COV group and 1743 patients in the CPV group. Patients who underwent TAVI with COV had lower risk of PPI (odds ratio 0.48; 95% confidence interval [CI] 0.33-0.70; p = 0.001) and higher implantation depths with COV (mean difference -0.83; 95% CI -1.2 to -0.45; p < 0.001). We did not observe any statistically significant differences in the rates of new LBBB, moderate/severe PVL, valve dislocation, need of second transcatheter heart valve, 30-day mortality, stroke, conversion to surgery, coronary obstruction, and post-TAVI mean gradients (mmHg). CONCLUSION: In TAVI with SEVs, the application of COV is associated with lower risk of PPI compared with the standard CPV without increasing risk for adverse outcomes.
Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Arritmias Cardíacas/etiología , Bloqueo de Rama/etiología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugíaRESUMEN
BACKGROUND: Permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) is associated with higher risk of mortality and rehospitalization for heart failure. Efforts to prevent conduction abnormalities (CA) requiring PPI after TAVI should be made. The membranous septum (MS) length and its interaction with implantation depth (ID-ΔMSID) could provide useful information about the risk of CA/PPI following TAVI. OBJECTIVES: To identify MS length and ΔMSID as predictors of CA/PPI following TAVI. METHODS: Study-level meta-analysis of studies published by September 30, 2022. RESULTS: Eighteen studies met our eligibility including 5740 patients. Shorter MS length was associated with a significantly higher risk of CA/PPI (per 1 mm decrease: odds ratio [OR] 1.60, 95% confidence interval [CI] 1.28-1.99, p < 0.001). Similarly, lower ΔMSID was associated with a significantly higher risk of CA/PPI (per 1 mm decrease: OR 1.75, 95% CI 1.32-2.31, p < 0.001). Meta-regression analyses revealed a statistically significant modulation of the effect of shorter MS length and lower ΔMSID on the outcome (CA/PPI) by balloon postdilatation (positive regression coefficients with p < 0.001); with increasing use of balloon postdilatation, the effect of shorter MS length and lower ΔMSID on the outcome increased. MS length and ΔMSID demonstrated excellent discriminative abilities, with diagnostic ORs equaling 9.49 (95% CI 4.73-19.06), and 7.19 (95% CI 3.31-15.60), respectively. CONCLUSION: Considering that short MS length and low ΔMSID are associated with higher risk of CA and PPI, we should include measurement of MS length in the pre-TAVI planning with MDCT and try to establish optimal ID values before the procedure to avoid CA/PPI.
Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo , Resultado del Tratamiento , Tomografía Computarizada por Rayos X , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugíaRESUMEN
INTRODUCTION: Haemolysis and inflammation contribute to cardiac surgery-associated acute kidney injury (CS-AKI). We aimed to assess the performance of plasma haemolysis index (HI) and interleukine-6 (IL-6) for the prediction of all-stage CS-AKI. We also assessed their ability to predict moderate-to-severe CS-AKI and to discriminate persistent from transient CS-AKI. METHODS: Adult patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) were prospectively included. Haemolysis index and IL-6 were measured immediately after the end of CPB and 6 hours later. Correction for haemodilution relied upon changes in albuminaemia. Persistent CS-AKI was defined as a steady/increasing CS-AKI stage between the 48th and the 60th postoperative hour as compared with the worst stage observed within the 48 first hours. RESULTS: Among 82 patients, CS-AKI occurred in 37 (45%) patients. Postoperative HI and IL-6 were positively correlated to the duration of CPB (r ≤ 0.51, p ≤ 0.0003). Whether we considered isolated measurements of HI or IL-6, their indexation to haemodilution or not, their kinetics and/or their combination, the prediction of all stage CS-AKI was inaccurate (area under the receiver operating characteristic curve [AUCROC]≤ 0.68) whereas moderate-to-severe CS-AKI (6 patients only) was predicted with an honourable performance (AUCROC = 0.77 [95%CI 0.67;0.86] and 0.87 [95%CI 0.77;0.93] for HI and IL-6, respectively). The persistent/transient nature of CS-AKI was inaccurately predicted (AUCROC ≤ 0.68). CONCLUSIONS: In a population in which most CS-AKI cases were mild, although they frequently (41%) persisted >48 hours, CS-AKI was inaccurately predicted by HI and/or IL-6. A better performance for moderate-to-severe CS-AKI prediction is likely. These preliminary findings are yet to be validated.
Asunto(s)
Lesión Renal Aguda , Procedimientos Quirúrgicos Cardíacos , Adulto , Humanos , Lipocalina 2 , Interleucina-6 , Proteínas Proto-Oncogénicas , Hemólisis , Proteínas de Fase Aguda , Biomarcadores , Valor Predictivo de las Pruebas , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/etiología , Puente Cardiopulmonar/efectos adversos , Creatinina , Complicaciones PosoperatoriasRESUMEN
IntraValvular Impedance (IVI) sensing is an innovative concept for monitoring heart valve prostheses after implant. We recently demonstrated IVI sensing feasible in vitro for biological heart valves (BHVs). In this study, for the first time, we investigate ex vivo the IVI sensing applied to a BHV when it is surrounded by biological tissue, similar to a real implant condition. A commercial model of BHV was sensorized with three miniaturized electrodes embedded in the commissures of the valve leaflets and connected to an external impedance measurement unit. To perform ex vivo animal tests, the sensorized BHV was implanted in the aortic position of an explanted porcine heart, which was connected to a cardiac BioSimulator platform. The IVI signal was recorded in different dynamic cardiac conditions reproduced with the BioSimulator, varying the cardiac cycle rate and the stroke volume. For each condition, the maximum percent variation in the IVI signal was evaluated and compared. The IVI signal was also processed to calculate its first derivative (dIVI/dt), which should reflect the rate of the valve leaflets opening/closing. The results demonstrated that the IVI signal is well detectable when the sensorized BHV is surrounded by biological tissue, maintaining the similar increasing/decreasing trend that was found during in vitro experiments. The signal can also be informative on the rate of valve opening/closing, as indicated by the changes in dIVI/dt in different dynamic cardiac conditions.
Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Prótesis Valvulares Cardíacas , Animales , Porcinos , Impedancia Eléctrica , Implantación de Prótesis , Animales de Laboratorio , Diseño de PrótesisRESUMEN
BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a transformative therapy for aortic stenosis. Despite rapid improvements in technology and techniques, serious complications remain relatively common and are not well described by single outcome measures. The purpose of this study was to determine whether there is site-level variation in TAVR outcomes in the United States using a novel 30-day composite measure. METHODS: We performed a retrospective cohort study using data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapies Registry to develop a novel ranked composite performance measure that incorporates mortality and serious complications. The selection and rank order of the complications for the composite was determined by their adjusted association with 1-year outcomes. Sites with risk-adjusted outcomes significantly more or less frequent than the national average based on a 95% probability interval were classified as performing worse or better than expected. RESULTS: The development cohort consisted of 52 561 patients who underwent TAVR between January 1, 2015, and December 31, 2017. Based on associations with 1-year risk-adjusted mortality and health status, we identified 4 periprocedural complications to include in the composite risk model in addition to mortality. Ranked empirically according to severity, these included stroke, major, life-threatening or disabling bleeding, stage III acute kidney injury, and moderate or severe perivalvular regurgitation. Based on these ranked outcomes, we found that there was significant site-level variation in quality of care in TAVR in the United States. Overall, better than expected site performance was observed in 25/301 (8%) sites, performance as expected was observed in 242/301 sites (80%), and worse than expected performance was observed in 34/301 (11%) sites. Thirty-day mortality; stroke; major, life-threatening, or disabling bleeding; and moderate or severe perivalvular leak were each substantially more common in sites with worse than expected performance as compared with other sites. There was good aggregate reliability of the model. CONCLUSIONS: There are substantial variations in the quality of TAVR care received in the United States and 11% of sites were identified as providing care below the average level of performance. Further study is necessary to determine structural, process-related, and technical factors associated with high- and low-performing sites.
Asunto(s)
Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/etiología , Manejo de la Enfermedad , Femenino , Encuestas de Atención de la Salud , Humanos , Masculino , Medición de Resultados Informados por el Paciente , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Pronóstico , Sistema de Registros , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Estados Unidos/epidemiologíaRESUMEN
Aortic stenosis with concomitant chronic kidney disease (CKD) represents a clinical challenge. Aortic stenosis is more prevalent and progresses more rapidly and unpredictably in CKD, and the presence of CKD is associated with worse short-term and long-term outcomes after aortic valve replacement. Because patients with advanced CKD and end-stage kidney disease have been excluded from randomized trials, clinicians need to make complex management decisions in this population that are based on retrospective and observational evidence. This statement summarizes the epidemiological and pathophysiological characteristics of aortic stenosis in the context of CKD, evaluates the nuances and prognostic information provided by noninvasive cardiovascular imaging with echocardiography and advanced imaging techniques, and outlines the special risks in this population. Furthermore, this statement provides a critical review of the existing literature pertaining to clinical outcomes of surgical versus transcatheter aortic valve replacement in this high-risk population to help guide clinical decision making in the choice of aortic valve replacement and specific prosthesis. Finally, this statement provides an approach to the perioperative management of these patients, with special attention to a multidisciplinary heart-kidney collaborative team-based approach.
Asunto(s)
American Heart Association , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/terapia , Manejo de la Enfermedad , Insuficiencia Renal Crónica/diagnóstico por imagen , Insuficiencia Renal Crónica/terapia , Estenosis de la Válvula Aórtica/epidemiología , Comorbilidad , Ecocardiografía/normas , Humanos , Insuficiencia Renal Crónica/epidemiología , Medición de Riesgo/métodos , Estados Unidos/epidemiologíaRESUMEN
After 15 years of successive randomized, controlled trials, indications for transcatheter aortic valve replacement (TAVR) are rapidly expanding. In the coming years, this procedure could become the first line treatment for patients with a symptomatic severe aortic stenosis and a tricuspid aortic valve anatomy. However, randomized, controlled trials have excluded bicuspid aortic valve (BAV), which is the most frequent congenital heart disease occurring in 1% to 2% of the total population and representing at least 25% of patients 80 years of age or older referred for aortic valve replacement. The use of a less invasive transcatheter therapy in this elderly population became rapidly attractive, and approximately 10% of patients currently undergoing TAVR have a BAV. The U.S. Food and Drug Administration and the "European Conformity" have approved TAVR for low-risk patients regardless of the aortic valve anatomy whereas international guidelines recommend surgical replacement in BAV populations. Given this progressive expansion of TAVR toward younger and lower-risk patients, heart teams are encountering BAV patients more frequently, while the ability of this therapy to treat such a challenging anatomy remains uncertain. This review will address the singularity of BAV anatomy and associated technical challenges for the TAVR procedure. We will examine and summarize available clinical evidence and highlight critical knowledge gaps regarding TAVR utilization in BAV patients. We will provide a comprehensive overview of the role of computed tomography scans in the diagnosis, and classification of BAV and TAVR procedure planning. Overall, we will offer an integrated framework for understanding the current role of TAVR in the treatment of bicuspid aortic stenosis and for guiding physicians in clinical decision-making.
Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , MasculinoRESUMEN
INTRODUCTION: Device infections constitute a major complication of transvenous pacemakers. Mechanical heart valves (MHV) increase the risk of infective endocarditis (IE) and pacemaker infection, requiring lifelong vitamin K-antagonists (VKA), which may affect patient management. Leadless pacemakers (LP) are associated with low infection rates, posing an attractive option in MHV patients requiring permanent pacing. This study describes outcomes following LP implantation in patients with MHV. METHODS: This is a multicenter, observational, retrospective study including consecutive patients implanted with an LP at 5 centers between June 2015 and January 2020. Procedural outcomes, antithrombotic management, complications, performance during follow-up and episodes of bacteremia and IE were compared between patients with and without an MHV (MHV and non-MHV groups). RESULTS: Four hundred fifty-nine patients were included (74 in the MHV group, 16.1%, and 385 in the non-MHV group, 83.9%). Procedural outcomes and acute electrical performance were comparable between groups. Vascular complications and cardiac perforation occurred in 2.7 versus 2.3% (p = 1) and 0% versus 0.8% (p = 1) in the MHV group and non-MHV group. One case of IE occurred in the MHV group and 2 in the non-MHV group. In MHV patients, uninterrupted VKA was used in 83.8%, whereas 16.2% were heparin-bridged. Vascular complication or tamponade occurred in 1 (8.3%) MHV heparin-bridged patient versus 1 (1.6%) MHV uninterrupted VKA patient (p = .3). CONCLUSION: LP implantation outcomes in MHV patients are comparable to the general LP population. Device-related infections are rare following LP implantation, including in patients with MHV. In the MHV group, periprocedural anticoagulation management was not associated with significantly different rates of tamponade or vascular complication.
Asunto(s)
Prótesis Valvulares Cardíacas , Marcapaso Artificial , Válvulas Cardíacas , Heparina , Humanos , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
OBJECTIVES: The present authors aimed to assess the late outcomes of patients undergoing aortic root enlargement (ARE) at the time of surgical aortic valve replacement (SAVR). DESIGN: Study-level meta-analysis with reconstructed time-to-event data. SETTING: Follow-up of patients after surgical procedure. PARTICIPANTS: Adult patients with aortic valve disease requiring surgery. INTERVENTIONS: SAVR with ARE versus SAVR without ARE. MEASUREMENTS AND MAIN RESULTS: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses reporting guideline. The following databases were searched for studies meeting the authors' inclusion criteria and published by November 30, 2021: PubMed/MEDLINE, Embase, SciELO, LILACS, CCTR/CENTRAL, and Google Scholar. Nine nonrandomized studies met the authors' eligibility criteria. All studies were nonrandomized. A total of 213,134 patients (SAVR with ARE: 7,556 patients; SAVR without ARE: 205,578 patients) were included from studies published from 1997 to 2021. The total rate of AAE was 3.7%, varying in the studies from 2.9% to 28.1%. The studies consisted of patients whose mean age varied from 63 to 79 years. Patients in the SAVR with ARE group had a significantly better overall survival (hazard ratio [HR] 0.94, 95% confidence interval [CI] 0.90-0.99, p = 0.016) in the unmatched populations, but the matched analysis revealed no difference between SAVR with/without ARE in terms of overall survival (HR, 1.06; 95% CI, 0.90-1.25; p = 0.474). CONCLUSIONS: In the context of patients undergoing SAVR with or without ARE, patients who undergo ARE do not experience worse late outcomes. Further randomized controlled trials are needed to confirm or refute the authors' current findings.
Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Persona de Mediana Edad , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del TratamientoRESUMEN
Valve-in-valve transcatheter aortic valve replacement for degenerated surgical bioprosthesis is becoming a more common therapeutic option. Rapid-deployment valves are novel, have distinct structural differences from standard surgical valves, and are increasingly used in minimal-access surgery. We report the case of a 61-year-old man who developed severe stenosis of an Edwards INTUITY Elite rapid-deployment valve and who subsequently underwent successful valve-in-valve placement of a self-expanding transcatheter valve. To our knowledge, this is the first description of the technical aspects of and considerations for using the self-expanding transcatheter platform in the Edwards INTUITY Elite valve.
Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Resultado del TratamientoRESUMEN
BACKGROUND: Comparative data on the clinical outcomes of TTK Chitra mechanical heart valve prosthesis (CHVP), an indigenously developed low-cost tilting disc valve and commonly used bileaflet valve, the St. Jude medical (SJM) prosthesis are sparse. METHODS: We conducted a retrospective follow-up study of consecutive patients undergoing mitral (MVR) and aortic valve replacement (AVR) with SJM or CHVP mechanical prostheses over a 6-year period at our institution. RESULTS: Seven hundred and thirty-five patients who underwent isolated MVR (n = 510) or AVR (n = 225) were included in the study. Patients with CHVP were younger and belonged to a lower socioeconomic class. The study cohort was followed-up for 2836 patient-years (SJM: 1865.1, CHVP: 971.0). All-cause mortality (p = 0.894), valve-related mortality (p = 0.681), prosthetic valve thrombosis (p = 0.155), embolism (p = 0.210), hemorrhage (p = 0.959) and infective endocarditis (IE, p = 0.084) were similar between both valve on follow-up. Estimated event free survival was 2302 ± 1 days in SJM as compared to 2484 ± 65 days in CHVP group (p = 0.393). Valve type was not an independent predictor of adverse events after adjusting for baseline data, time in therapeutic range and aspirin use. Subgroup analysis of patients who underwent MVR and AVR showed similar functional improvement and outcomes, except for a higher incidence of IE with SJM at the aortic position (p = 0.041). CONCLUSION: The indigenously developed, low-cost CHVP has comparable midterm clinical performance as SJM in aortic or mitral positions.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Aórtica/cirugía , Proteínas de Ciclo Celular , Aleaciones Dentales , Estudios de Seguimiento , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/cirugía , Diseño de Prótesis , Proteínas Serina-Treonina Quinasas , Proteínas Tirosina Quinasas , Estudios RetrospectivosRESUMEN
BACKGROUND: Outcomes of transcatheter aortic valve implantation (TAVI) versus surgical aortic valve replacement (SAVR) in patients with aortic stenosis and bicuspid aortic valve (BAV) must be better investigated. METHODS: A meta-analysis including studies published by January 2022 reporting immediate outcomes (in-hospital death, stroke, acute kidney injury [AKI], major bleeding, new permanent pacemaker implantation [PPI], paravalvular leakage [PVL]), mortality in the follow-up (with Kaplan-Meier curves for reconstruction of individual patient data). RESULTS: Five studies met our eligibility criteria. No statistically significant difference was observed for in-hospital death, stroke, AKI, and PVL. TAVI was associated with lower risk of major bleeding (odds ratio [OR]: 0.29; 95% confidence interval [CI]: 0.12-0.69; p = .025), but higher risk of PPI (OR: 2.00; 95% CI: 1.05-3.77; p = .041). In the follow-up, mortality after TAVI was significantly higher in the analysis with the largest samples (HR: 1.24, 95% CI: 1.01-1.53, p = .043), but no statistically significant difference was observed with risk-adjusted populations (HR: 1.06, 95% CI: 0.86-1.32, p = .57). Landmark analyses suggested a time-varying risk with TAVI after 10 and 13 months in both largest and risk-adjusted populations (HR: 2.13, 95% CI: 1.45-3.12, p < .001; HR: 1.7, 95% CI: 1.11-2.61, p = .015, respectively). CONCLUSION: Considering the immediate outcomes and comparable overall survival observed in risk-adjusted populations, TAVI can be used safely in selected BAV patients. However, a time-varying risk is present (favoring SAVR over TAVI at a later timepoint). This finding was likely driven by higher rates of PPI with TAVI.
Asunto(s)
Lesión Renal Aguda , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Lesión Renal Aguda/etiología , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Mortalidad Hospitalaria , Humanos , Válvula Mitral/cirugía , Factores de Riesgo , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del TratamientoRESUMEN
Over the last decade, sutureless valves (Perceval, LivaNova PLC) were brought to the market as an alternative to stented valves for patients requiring surgical aortic valve replacement (SAVR). However, Perceval demands special steps for implantation, among which we can mention specific training for the surgical team members. Sternal-sparing cardiac procedures are conceived to limit surgical trauma, but the technical requirements and preoperative planning are more challenging than those for conventional sternotomy. SAVR is frequently carried out through an upper hemisternotomy, but the right anterior thoracotomy (RAT) represents an even less traumatic, technical advancement. In the context of SAVR with RAT, Perceval has been considered the "perfect marriage." In patients with bicuspid aortic valve (BAV), some surgeons initially avoided the Perceval valve but, with growing experience, the prosthesis has been used for a wide variety of indications. According to an international consensus statement recently published, there are 3 BAV types: the fused BAV, the 2-sinus BAV and the partial-fusion BAV, each with specific phenotypes. The 2-sinus BAV has 2 cusps, roughly equal in size and shape, each cusp occupying 180° of the annular circumference, with only 2 aortic sinuses, resulting in a 2-sinus/2-cusp valve without raphe and with 180° commissural angles. Since the elliptic aortic annulus in BAV patients poses a challenge for sutureless valves and the RAT approach has been increasingly adopted for minimally invasive SAVR, our description of the surgical technique focuses on the specific procedural details in the scenario of 2-sinus BAV laterolateral phenotype.
Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Válvula Aórtica/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
Transcatheter mitral valve implantation (TMVI) has emerged as a less invasive approach potentially surmounting some of the current hurdles associated with transcatheter edge-to-edge repair and high-risk mitral valve surgery. In this review, we aimed to outline the main scenarios in the TMVI field, highlight current and upcoming devices, and describe challenges and clinical results. Finally, we briefly discuss the future perspectives for this emerging field and how TMVI might further advance the field of transcatheter treatments of mitral valve disease.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Resultado del TratamientoRESUMEN
Transcatheter aortic valve replacement (TAVR) has already received the green light for high-, intermediate- and low-risk profiles and is an alternative for all patients regardless of age. It is clear that there has been a push towards the use of TAVR in younger and younger patients (<65 years), which has never been formally tested in randomized controlled trials but seems inevitable as TAVR technology makes steady progress. Lifetime management as a concept will set the tone in the field of the structural heart. Some subjects in this scenario arise, including the importance of optimized prosthetic hemodynamics for lifetime care; surgical procedures in the aortic root; management of structural valve degeneration with valve-in-valve procedures (TAVR-in-surgical aortic valve replacement [SAVR] and TAVR-in-TAVR) and redo SAVR; commissural alignment and cusp overlap for TAVR; the rise in the number of surgical procedures for TAVR explantation; and the renewed interest in the Ross procedure. This article reviews all these issues which will become commonplace during heart team meetings and preoperative conversations with patients in the coming years.
Asunto(s)
Enfermedad de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Estenosis de la Válvula Aórtica/cirugía , Humanos , Factores de Riesgo , Resultado del TratamientoRESUMEN
OBJECTIVES: To compare outcomes of complete transcatheter (TAVI plus PCI) versus complete surgical (SAVR plus CABG) approach to treat patients with aortic stenosis (AS) and concomitant coronary artery disease (CAD). METHODS: Study-level meta-analysis with reconstructed time-to-event data including studies published by November 2021. The primary endpoints were 30-day mortality, overall survival, and major adverse cardiovascular and cerebrovascular events (MACCE). The secondary endpoints were 30-day stroke, myocardial infarction, and permanent pacemaker implantation (PPI); in-hospital major vascular events and acute kidney injury (AKI). RESULTS: Eight studies met our eligibility criteria, including a total of 33,286 patients (3448 for TAVI plus PCI and 29,838 for SAVR plus CABG). The pooled risk of 30-day mortality was lower for TAVI plus PCI (OR 0.63; 95% CI 0.51-0.80; p < .001). Patients undergoing TAVI plus PCI had lower risk of in-hospital AKI (OR 0.49; 95% CI 0.28-0.85; p = .01), however, higher risk of major vascular events (OR 7.33; 95% CI 1.80-29.85; p = .005) and higher risk of PPI (OR 2.96; 95% CI 1.80-4.85; p < .001). No statistically significant difference was observed for myocardial infarction and stroke between the groups. In the follow-up analyses, we observed a higher risk of mortality (HR 1.64, 95% CI 1.36-1.96, p < .001) and MACCE with TAVI plus PCI (HR 1.35 (95% CI 1.08-1.69, p = .009). CONCLUSION: Patients who undergo TAVI plus PCI (in comparison with SAVR plus CABG) initially experience lower rates of in-hospital death and AKI; however, they experience significantly lower survival rates and more MACCE at 5-year follow up. Structural heart surgeons and interventional cardiologists should consider these aspects when referring patients for one approach or the other.