Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 340
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Nano Lett ; 24(33): 10355-10361, 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39119944

RESUMEN

Combining rare earth elements with the halide perovskite structure offers valuable insights into designing nonlead (Pb) luminescent materials. However, most of these compositions tend to form zero-dimensional (0D) networks of metal-halide polyhedra, with higher-dimensional (1D, 2D, and 3D) structures receiving relatively less exploration. Herein, we present synthesis and optical properties of Cs3CeCl6·3H2O, characterized by its unique 1D crystal structure. The conduction band minimum of Cs3CeCl6·3H2O becomes less localized as a result of the increased structural dimension, making it possible for the materials to achieve an efficient electrical injection. For both Cs3CeCl6·3H2O single crystals and nanocrystals, we also observed remarkable luminescence with near-unity photoluminescence quantum yield and exceptional phase stability. Cs3CeCl6·3H2O single crystals demonstrate an X-ray scintillation light yield of 31900 photons/MeV, higher than that of commercial LuAG:Ce (22000 photons/MeV); electrically driven light-emitting diodes fabricated with Cs3CeCl6·3H2O nanocrystals yield the characteristic emission of Ce3+, indicating their potential use in next-generation violet-light-emitting devices.

2.
Small ; : e2403234, 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38963174

RESUMEN

Manganese halides are one of the most potential candidates for large-area flat-panel detection owing to their biological safety and all-solution preparation. However, reducing photon scattering and enhancing the efficient luminescence of scintillator screens remains a challenge due to their uncontrollable crystallization and serious nonradiative recombination. Herein, an organic cation modulation is reported to control the crystallization process and enhance the luminescence properties of manganese halides. Given the industrial requirements of the X-ray flat-panel detector, the large-area A2MnBr4 screen (900 cm2) with excellent uniformity is blade-coated at 60 °C. Theoretical calculations and in situ measurements reveal that organic cations with larger steric hindrance can slow down the crystallization of the screen, thus neatening the crystal arrangement and reducing the photon scattering. Moreover, larger steric hindrance can also endow the material with higher exciton binding energy, which is beneficial for restraining nonradiative recombination. Therefore, the BPP2MnBr4 (BPP = C25H22P+) screen with larger steric hindrance exhibits a superior spatial resolution (>20 lp mm-1) and ultra-low detection limit (< 250 nGyair s-1). This is the first time steric hindrance modulation is used in blade-coated scintillator screens, and it believes this study will provide some guidance for the development of high-performance manganese halide scintillators.

3.
Small ; 20(21): e2307758, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38100187

RESUMEN

Metal halide nanocrystals (MHNCs) embedded in a polymer matrix as flexible X-ray detector screens is an effective strategy with the advantages of low cost, facile preparation, and large area flexibility. However, MHNCs easily aggregate during preparation, recombination, under mechanical force, storage, or high operating temperature. Meanwhile, it shows an unmatched refractive index with polymer, resulting in low light yield. The related stability and properties of the device remain a huge unrevealed challenge. Herein, a composite screen (CZBM@AG-PS) by integrating MHNCs (Cs2ZnBr4: Mn2+ as an example) into silica aerogel (AG) and embedded in polystyrene (PS) is successfully developed. Further characterization points to the high porosity AG template that can effectively improve the dispersion of MHNCs in polymer detector screens, essentially decreasing nonradiative transition, Rayleigh scattering, and performance aging induced by aggregation in harsh environments. Furthermore, the higher light output and lower optical crosstalk are also achieved by a novel light propagation path based on the MHNCs/AG and AG/PS interfaces. Finally, the optimized CZBM@AG-PS screen shows much enhanced light yield, spatial resolution, and temperature stability. Significantly, the strategy is proven universal by the performance tests of other MHNCs embedded composite films for ultra-stable and efficient X-ray imaging.

4.
Nanotechnology ; 2024 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-39389088

RESUMEN

Metal halide scintillators serve as a compelling substitute for traditional scintillators in X-ray detection and imaging due to their low-temperature fabrication process, high light yield and mechanical flexibility. Nevertheless, the spatial resolution and photoluminescence quantum yield (PLQY) of these films are hindered by the agglomeration and uneven distribution of metal halides crystal particles during the fabrication process. We introduce a modified fabrication approach for metal halide scintillator films involving an additional step of ethyl acetate (EA) treatment, resulting in the preparation of a smooth EA-treated (Ph4P)2MnBr4/Polydimethylsiloxane film. The carbonyl groups within EA interact with elements of the (Ph4P)2MnBr4 microcrystals powder, ensuring uniform dispersion and preventing agglomeration. The EA-treated composite film demonstrates a remarkable PLQY of approximately 95% and an impressive spatial resolution of 14 lp/mm, with enhanced stability under harsh environments. These characteristics ensure its suitability as a high-performance X-ray imaging scintillator. .

5.
J Appl Clin Med Phys ; 25(6): e14387, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38778567

RESUMEN

INTRODUCTION: Radiation dose measurement is an essential part of radiotherapy to verify the correct delivery of doses to patients and ensure patient safety. Recent advancements in radiotherapy technology have highlighted the need for fast and precise dosimeters. Technologies like FLASH radiotherapy and magnetic-resonance linear accelerators (MR-LINAC) demand dosimeters that can meet their unique requirements. One promising solution is the plastic scintillator-based dosimeter with high spatial resolution and real-time dose output. This study explores the feasibility of using the LuSy dosimeter, an in-house developed plastic scintillator dosimeter for dose verification across various radiotherapy techniques, including conformal radiotherapy (CRT), intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT), and stereotactic radiosurgery (SRS). MATERIALS AND METHODS: A new dosimetry system, comprising a new plastic scintillator as the sensing material, was developed and characterized for radiotherapy beams. Treatment plans were created for conformal radiotherapy, IMRT, VMAT, and SRS and delivered to a phantom. LuSy dosimeter was used to measure the delivered dose for each plan on the surface of the phantom and inside the target volumes. Then, LuSy measurements were compared against an ionization chamber, MOSFET dosimeter, radiochromic films, and dose calculated using the treatment planning system (TPS). RESULTS: For CRT, surface dose measurement by LuSy dosimeter showed a deviation of -5.5% and -5.4% for breast and abdomen treatment from the TPS, respectively. When measuring inside the target volume for IMRT, VMAT, and SRS, the LuSy dosimeter produced a mean deviation of -3.0% from the TPS. Surface dose measurement resulted in higher TPS discrepancies where the deviations for IMRT, VMAT, and SRS were -2.0%, -19.5%, and 16.1%, respectively. CONCLUSION: The LuSy dosimeter was feasible for measuring radiotherapy doses for various treatment techniques. Treatment delivery verification enables early error detection, allowing for safe treatment delivery for radiotherapy patients.


Asunto(s)
Estudios de Factibilidad , Aceleradores de Partículas , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Aceleradores de Partículas/instrumentación , Radiocirugia/métodos , Dosímetros de Radiación , Radioterapia Conformacional/métodos , Radioterapia Conformacional/instrumentación , Radiometría/métodos , Radiometría/instrumentación , Órganos en Riesgo/efectos de la radiación , Neoplasias/radioterapia
6.
J Appl Clin Med Phys ; 25(8): e14451, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38952057

RESUMEN

PURPOSE: This study investigated the potential of a commercially available plastic scintillator, the Exradin W2, as a real-time dosimeter for ultra-high-dose-rate (UHDR) electron beams. This work aimed to characterize this system's performance under UHDR conditions and addressed limitations inherent to other conventional dosimetry systems. METHODS AND MATERIALS: We assessed the W2's performance as a UHDR electron dosimeter using a 16 MeV UHDR electron beam from the FLASH research extension (FLEX) system. Additionally, the vendor provided a beta firmware upgrade to better handle the processing of the high signal generated in the UHDR environment. We evaluated the W2 regarding dose-per-pulse, pulse repetition rate, charge versus distance, and pulse linearity. Absorbed dose measurements were compared against those from a plane-parallel ionization chamber, optically stimulated luminescent dosimeters and radiochromic film. RESULTS: We observed that the 1 × 1 mm W2 scintillator with the MAX SD was more suitable for UHDR dosimetry compared to the 1 × 3 mm W2 scintillator, capable of matching film measurements within 2% accuracy for dose-per-pulse up to 3.6 Gy/pulse. The W2 accurately ascertained the inverse square relationship regarding charge versus virtual source distance with R2 of ∼1.00 for all channels. Pulse linearity was accurately measured with the W2, demonstrating a proportional response to the delivered pulse number. There was no discernible impact on the measured charge of the W2 when switching between the available repetition rates of the FLEX system (18-180 pulses/s), solidifying consistent beam output across pulse frequencies. CONCLUSIONS: This study tested a commercial plastic scintillator detector in a UHDR electron beam, paving the way for its potential use as a real-time, patient-specific dosimetry tool for future FLASH radiotherapy treatments. Further research is warranted to test and improve the signal processing of the W2 dosimetry system to accurately measure in UHDR environments using exceedingly high dose-per-pulse and pulse numbers.


Asunto(s)
Electrones , Plásticos , Conteo por Cintilación , Plásticos/química , Conteo por Cintilación/instrumentación , Conteo por Cintilación/métodos , Humanos , Radiometría/métodos , Radiometría/instrumentación , Dosificación Radioterapéutica , Fantasmas de Imagen , Aceleradores de Partículas/instrumentación
7.
J Appl Clin Med Phys ; 25(5): e14320, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38454657

RESUMEN

PURPOSE: To directly compare the radiation and imaging isocenters of a proton treatment machine, we developed and evaluated a real-time radiation isocenter verification system. METHODS: The system consists of a plastic scintillator (PI-200, Mitsubishi Chemical Corporation, Tokyo, Japan), an acrylic phantom, a steel ball on the detachable plate, Raspberry Pi 4 (Raspberry Pi Foundation, London, UK) with camera module, and analysis software implemented through a Python-based graphical user interface (GUI). After kV imaging alignment of the steel ball, the imaging isocenter defined as the position of the steel ball was extracted from the optical image. The proton star-shot was obtained by optical camera because the scintillator converted proton beam into visible light. Then the software computed both the minimum circle radius and the radiation isocenter position from the star-shot. And the deviation between the imaging isocenter and radiation isocenter was calculated. We compared our results with measurements obtained by Gafchromic EBT3 film (Ashland, NJ, USA). RESULTS: The minimum circle radii were averaged 0.29 and 0.41 mm while the position deviations from the radiation isocenter to the laser marker were averaged 0.99 and 1.07 mm, for our system and EBT3 film, respectively. Furthermore, the average position difference between the radiation isocenter and imaging isocenter was 0.27 mm for our system. Our system reduced analysis time by 10 min. CONCLUSIONS: Our system provided automated star-shot analysis with sufficient accuracy, and it is cost-effective alternative to conventional film-based method for radiation isocenter verification.


Asunto(s)
Fantasmas de Imagen , Terapia de Protones , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Programas Informáticos , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Aceleradores de Partículas/instrumentación , Neoplasias/radioterapia , Neoplasias/diagnóstico por imagen , Algoritmos
8.
Sensors (Basel) ; 24(7)2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38610351

RESUMEN

Proton radiography is a promising development in proton therapy, and researchers are currently exploring optimal detector materials to construct proton radiography detector arrays. High-density glass scintillators may improve integrating-mode proton radiography detectors by increasing spatial resolution and decreasing detector thickness. We evaluated several new scintillators, activated with europium or terbium, with proton response measurements and Monte Carlo simulations, characterizing relative luminosity, ionization quenching, and proton radiograph spatial resolution. We applied a correction based on Birks's analytical model for ionization quenching. The data demonstrate increased relative luminosity with increased activation element concentration, and higher relative luminosity for samples activated with europium. An increased glass density enables more compact detector geometries and higher spatial resolution. These findings suggest that a tungsten and gadolinium oxide-based glass activated with 4% europium is an ideal scintillator for testing in a full-size proton radiography detector.

9.
Sensors (Basel) ; 24(12)2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38931622

RESUMEN

Thanks to advancements in silicon photomultiplier sensors (SiPMs) and system-on-chip (SoC) technology, our INFN Roma1 group developed ArduSiPM in 2012, the first all-in-one scintillator particle detector in the literature. It used a custom Arduino Due shield to process fast signals, utilizing the Microchip Sam3X8E SoC's internal peripherals to control and acquire SiPM signals. The availability of radiation-tolerant SoCs, combined with the goal of reducing system space and weight, led to the development of an innovative second-generation board, a better-performing device called Cosmo ArduSiPM, suitable for space missions. The architecture of the new detector is based on the Microchip SAMV71 300 MHz, 32-bit ARM® Cortex®-M7 (Microchip Technology Inc., Chandler, AZ, USA). While the analog front-end is essentially identical to the ArduSiPM, it utilizes components with the smallest possible package. The board fits in a CubeSat module. Thanks to the compact design, the board has two independent channels, with a total weight of only 40 grams within a CubeSat form factor. The ArduSiPM architecture is based on a single microcontroller and fast discrete analog electronics. It benefits from the continued development of SoCs related to the IoT (Internet of Things) market. Compared with a system with a custom ASIC, this architecture based on software and SoC capabilities offers considerable advantages in terms of cost and development time. The ability to incorporate new commercial SoCs, continuously emerging from advancements in the aerospace and automotive industries, provides the system with a robust foundation for sustained growth over the years. A detailed characterization of the hardware and the system's response to different photon fluxes is presented in this article. Additionally, coupling the device with a scintillator was tested at the end of this article as a preliminary trial for future measurements, showing potential for further enhancement of the detector's capabilities.

10.
Sensors (Basel) ; 24(10)2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38793828

RESUMEN

After the Fukushima nuclear power plant accident in 2011, many types of survey meters were used, including Geiger-Müller (GM) survey meters, which have long been used to measure ß-rays. Recently, however, a novel radiation survey meter that uses a plastic-scintillation sensor has been developed. Although manufacturers' catalog data are available for these survey meters, there have been no user reports on performance. In addition, the performance of commercial plastic-scintillation survey meters has not been evaluated. In this study, we experimentally compared the performance of a plastic-scintillation survey meter with that of a GM survey meter. The results show that the two instruments performed very similarly in most respects. The GM survey meter exhibited count losses when the radiation count rate was high, whereas the plastic-scintillation survey meter remained accurate under such circumstances, with almost no count loss at high radiation rates. For measurements at background rates (i.e., low counting rates), the counting rates of the plastic-scintillation and GM survey meters were similar. Therefore, an advantage of plastic-scintillation survey meters is that they are less affected by count loss than GM survey meters. We conclude that the plastic-scintillation survey meter is a useful ß-ray measuring/monitoring instrument.

11.
Angew Chem Int Ed Engl ; 63(39): e202407074, 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-38978178

RESUMEN

Designing and synthesizing multifunctional hybrid copper halides with near ultraviolet (NUV) light-excited high-energy emission (<500 nm) remains challenging. Here, a pair of broadband-excited high-energy emitting isomers, namely, α-/ß-(MePh3P)2CuI3 (MePh3P=methyltriphenylphosphonium), were synthesized. α-(MePh3P)2CuI3 with blue emission peaking at 475 nm is firstly discovered wherein its structure contains regular [CuI3]2- triangles and crystallizes in centrosymmetric space group P21/c. While ß-(MePh3P)2CuI3 featuring distorted [CuI3]2- planar triangles shows inversion symmetry breaking and crystallizes in the noncentrosymmetric space group P21, which exhibits cyan emission peaking at 495 nm with prominent near-unity photoluminescence quantum yield and the excitation band ranging from 200 to 450 nm. Intriguingly, ß-(MePh3P)2CuI3 exhibits phase-matchable second-harmonic generation response of 0.54×KDP and a suitable birefringence of 0.06@1064 nm. Furthermore, ß-(MePh3P)2CuI3 also can be excited by X-ray radioluminescence with a high scintillation light yield of 16193 photon/MeV and an ultra-low detection limit of 47.97 nGy/s, which is only 0.87 % of the standard medical diagnosis (5.5 µGy/s). This work not only promotes the development of solid-state lighting, laser frequency conversion and X-ray imaging, but also provides a reference for constructing multifunctional hybrid metal halides.

12.
Angew Chem Int Ed Engl ; 63(18): e202401949, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38437064

RESUMEN

X-ray scintillators have gained significant attention in medical diagnostics and industrial applications. Despite their widespread utility, scintillator development faces a significant hurdle when exposed to elevated temperatures, as it usually results in reduced scintillation efficiency and diminished luminescence output. Here we report a molecular design strategy based on a hybrid perovskite (TpyBiCl5) that overcomes thermal quenching through multi-excited state switching. The structure of perovskite provides a platform to modulate the luminescence centers. The rigid framework constructed by this perovskite structure stabilized its triplet states, resulting in TpyBiCl5 exhibiting an approximately 12 times higher (45 % vs. 3.8 %) photoluminescence quantum yield of room temperature phosphorescence than that of its organic ligand (Tpy). Most importantly, the interactions between the components of this perovskite enable the mixing of different excited states, which has been revealed by experimental and theoretical investigations. The TpyBiCl5 scintillator exhibits a detection limit of 38.92 nGy s-1 at 213 K and a detection limit of 196.31 nGy s-1 at 353 K through scintillation mode switching between thermally activated delayed fluorescence and phosphorescence. This work opens up the possibility of solving the thermal quenching in X-ray scintillators by tuning different excited states.

13.
Angew Chem Int Ed Engl ; 63(3): e202316190, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38009958

RESUMEN

With the increasing demands of X-ray detection and medical diagnosis, organic scintillators with intense and tunable X-ray excited emission have been becoming important. To guarantee the X-ray absorption, heavy atoms were widely added in reported organic scintillators, which led to emission quenching. In this work, we propose a new strategy to realize organic scintillators through the host-guest doping strategy. Then the X-ray absorption centers (host) and emission centers (guest) are separated. Under X-ray excitation, these materials displayed intense and readily tunable emissions ranging from green (520 nm) to near infrared (NIR) regions (682 nm). Besides, the relationship between the X-ray absorption and spatial arrangement of the heavy atoms in the host matrix was also revealed. The potential application of these wide-range color tunable organic host-guest scintillators in X-ray imaging were demonstrated. This work provides a new feasible strategy for constructing high-performance organic scintillators with tunable luminescence properties.

14.
Angew Chem Int Ed Engl ; : e202412253, 2024 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-39259427

RESUMEN

Self-trapped exciton (STE) emission, typified by antimony (Sb), with broadband characteristics, represents the next generation of materials for solid-state lighting and radiation detection. However, little is known about the multiexciton behavior of the Sb emission center. Here, we proposed a general approach for designing antimony-centered multi-exciton emitting materials through self-assembly. Benefitting from controllable multiexciton behavior, dual-band white light emission spanning the entire visible spectrum was achieved. Relying on the reduction of an effective atomic number brought by self-assembly, excellent scintillation response to ß-rays was attained. This study offers unprecedented insight into hybrid single/triple STE emission and unveils new avenues for single-emitter white-light emission, as well as radiographic testing using low-risk ß-rays as sources.

15.
Angew Chem Int Ed Engl ; : e202410514, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38966937

RESUMEN

Organic scintillators are praised for their abundant element reserves, facile preparation procedures, and rich structures. However, the weak X-ray attenuation ability and low exciton utilization efficiency result in unsatisfactory scintillation performance. Herein, a new family of highly efficient organic phosphonium halide salts with thermally activated delayed fluorescence (TADF) are designed by innovatively adopting quaternary phosphonium as the electron acceptor, while dimethylamine group and halide anions (I-) serve as the electron donor. The prepared butyl(2-[2-(dimethylamino)phenyl]phenyl)diphenylphosphonium iodide (C4-I) exhibits bright blue emission and an ultra-high photoluminescence quantum yield (PLQY) of 100 %. Efficient charge transfer is realized through the unique n-π and anion-π stacking in solid-state C4-I. Photophysical studies of C4-I suggest that the incorporation of I accounts for high intersystem crossing rate (kISC) and reverse intersystem crossing rate (kRISC), suppressing the intrinsic prompt fluorescence and enabling near-pure TADF emission at room temperature. Benefitting from the large Stokes shift, high PLQY, efficient exciton utilization, and remarkable X-ray attenuation ability endowed by I, C4-I delivers an outstanding light yield of 80721 photons/MeV and a low limit of detection (LoD) of 22.79 nGy ⋅ s-1. This work would provide a rational design concept and open up an appealing road for developing efficient organic scintillators with tunable emission, strong X-ray attenuation ability, and excellent scintillator performance.

16.
Angew Chem Int Ed Engl ; 63(20): e202402704, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38414169

RESUMEN

Thermally activated delayed fluorescence (TADF) emitters featuring through-space charge transfer (TSCT) can be excellent candidates for piezochromic luminescent (PCL) materials due to their structural dynamics. Spatial donor-acceptor (D-A) stacking arrangements enable the modulation of inter- and intramolecular D-A interactions, as well as spatial charge transfer states, under varying pressure conditions. Herein, we demonstrate an effective approach toward dynamic reversible full-color PCL materials with TSCT-TADF characteristics. Their single crystals exhibit a full-color-gamut PCL process spanning a range of 170 nm. Moreover, the TSCT-TADF-PCL emitters display a unity photoluminescence quantum yield, and show promising application in X-ray scintillator imaging.

17.
J Fluoresc ; 33(5): 1705-1716, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36826726

RESUMEN

Organic liquid scintillation detectors are widely used to measure the presence of radiation. With these devices, there are advantages in that they are easy to manufacture, large in size, and have a short fluorescence decay time. However, they are not suitable for gamma spectroscopy because they are composed of a low-atomic-number material. In this regard, alternative materials for the secondary solute used in basic organic liquid scintillators have been investigated, and the applicability of alternative materials, the detection characteristics, and neutron/gamma identification tests were all assessed. 7-Diethylamino-4-methylcoumarin (DMC), selected as an alternative material, is a benzopyrone derivative in the form of colorless crystals with high fluorescence, a high quantum yield in the visible region, and excellent light stability. In addition, it has a large Stokes shift, and solubility in a solvent is good. Through an analysis in this study, it was found that the absorption wavelength range of DMC coincides with the emission wavelength range of PPO, which is the primary solute used with DMC. Finally, it was confirmed that the optimal concentration of DMC was 0.08 wt%. As a result of performing gamma and neutron measurement tests using a DMC-based liquid scintillator, it was found to perform well (FOM = 1.42) compared to a commercial liquid scintillator, BC-501A.

18.
Sensors (Basel) ; 23(23)2023 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-38067863

RESUMEN

Liquid scintillators are extensively employed as targets in neutrino experiments and in medical radiography. Perovskite nanocrystals are recognized for their tunable emission spectra and high photoluminescence quantum yields. In this study, we investigated the feasibility of using perovskites as an alternative to fluor, a substance that shifts the wavelengths. The liquid scintillator candidates were synthesized by doping perovskite nanocrystals with emission wavelengths of 450, 480, and 510 nm into fluor PPO with varying nanocrystal concentrations in a toluene solvent. The several properties of the perovskite nanocrystal-doped liquid scintillator were measured and compared with those of a secondary wavelength shifter, bis-MSB. The emission spectra of the perovskite nanocrystal-doped liquid scintillator exhibited a distinct monochromatic wavelength, indicating energy transfer from PPO to the perovskite nanocrystals. Using a 60Co radioactive source setup with two photomultiplier tubes (PMTs), the light yields, pulse shape, and wavelength shifts of the scintillation events were measured. The light yields were evaluated based on the observed Compton edges from γ-rays, and compared across the synthesized samples. A decrease (or increase) in area-normalized PMT pulse height was observed at higher perovskite nanocrystal (or PPO) concentrations. The results demonstrated the sufficient potential of perovskite nanocrystals as an alternative to traditional wavelength shifters in a liquid scintillator.

19.
Sensors (Basel) ; 23(5)2023 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-36904932

RESUMEN

Neutrinos are difficult to detect because they weakly interact with matter, making their properties least known. The response of the neutrino detector depends on the optical properties of the liquid scintillator (LS). Monitoring any characteristic changes in the LS helps to understand the temporal variation of detector response. In this study, a detector filled with LS was used to study the characteristics of the neutrinos detector. We investigated a method to distinguish the concentrations of PPO and bis-MSB, which are fluors added to LS, through a photomultiplier tube (PMT) acting as an optical sensor. Conventionally, it is very challenging to discriminate the flour concentration dissolved in LS. We employed the information of pulse shape and PMT coupled with the short-pass filter. To date, no literature report on a measurement using such an experimental setup has been published. As the concentration of PPO was increased, changes in the pulse shape were observed. In addition, as the concentration of bis-MSB was increased, a decrease in the light yield was observed in the PMT equipped with the short-pass filter. This result suggests the feasibility of real-time monitoring of LS properties, which are correlated with the fluor concentration, using a PMT without extracting the LS samples from the detector during the data acquisition process.

20.
Sensors (Basel) ; 23(9)2023 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-37177494

RESUMEN

This paper describes a practical method for obtaining the spectra of lights emitted by a fluor in a liquid scintillator (LS) using a digital camera. The emission wavelength results obtained using a digital image were compared with those obtained using a fluorescence spectrophotometer. For general users, conventional spectrophotometers are expensive and difficult to access. Moreover, their experimental measurement setup and processes are highly complicated, and they require considerable care in handling. To overcome these limitations, a feasibility study was performed to obtain the emission spectrum through image analysis. Specifically, the emission spectrum of a fluor dissolved in a liquid scintillator was obtained using digital image analysis. An image processing method was employed to convert the light irradiated during camera exposure into wavelengths. Hue (H) and wavelength (W) are closely related. Thus, we obtained an H-W response curve in the 400~450 nm wavelength region, using a light-emitting diode. Another relevant advantage of the method described in this study is its non-invasiveness in sealed LS samples. Our results showed that this method has the potential to accurately investigate the emission wavelengths of fluor within acceptable uncertainties. We envision the use of this method to perform experiments in chemistry and physics laboratories in the future.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA