Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 697
Filtrar
Más filtros

Intervalo de año de publicación
1.
J Vasc Surg ; 79(5): 991-996, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38262566

RESUMEN

OBJECTIVE: Left vertebral artery revascularization is indicated in surgery involving zone 2 of the aortic arch and is typically accomplished indirectly via subclavian artery revascularization. For aberrant left vertebral anatomy, direct revascularization is indicated. Our objective was to compare the outcomes of direct vertebral artery revascularization with indirect subclavian artery revascularization for treating aortic arch pathology and to identify predictors of mortality. METHODS: A retrospective cohort study was conducted at a single tertiary hospital, including patients who underwent open or endovascular vertebral artery revascularization from 2005 to 2022. Those who underwent direct vertebral revascularization were compared with those who were indirectly revascularized via subclavian artery revascularization. The outcomes of interest were a composite outcome (any of death, stroke, nerve injury, and thrombosis) and mortality. Univariate logistic regression models were fitted to quantify the strength of differences between the direct and indirect revascularization cohorts. Cox regression was used to identify mortality predictors. RESULTS: Of 143 patients who underwent vertebral artery revascularization, 21 (14.7%) had a vertebral artery originating from the aortic arch. The median length of stay was 10 days (interquartile range, 6-20 days), and demographics were similar between cohorts. The incidence of composite outcome, bypass thrombosis, and hoarseness was significantly higher in the direct group (42.9% vs 18.0%, P = .019; 33.3% vs 0.8%, P < .0001; 57.1% vs 18.0%, P < .001, respectively). The direct group was approximately three times more likely to experience the composite outcome (odds ratio, 3.41; 95% confidence interval, 1.28, 9.08); similarly, this group was approximately six times more likely to have hoarseness (odds ratio, 5.88; 95% confidence interval, 2.21, 15.62). There was no significant difference in mortality rates at 30 days, 1, 3, 5, and 10 years of follow-up. Age, length of hospital stay, and congestive heart failure were identified as predictors of higher mortality. After adjusting for these covariates, the group itself was not an independent predictor of mortality. CONCLUSIONS: Direct vertebral revascularization was associated with higher rates of composite outcome (death, stroke, nerve injury, and thrombosis), bypass thrombosis and hoarseness. Patients with aberrant vertebral anatomy are at higher risks of these complications compared with patients with standard arch anatomy. However, after adjusting for other factors, mortality rates were not significantly different between the groups.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Accidente Cerebrovascular , Trombosis , Humanos , Arteria Vertebral/diagnóstico por imagen , Arteria Vertebral/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Estudios Retrospectivos , Ronquera/complicaciones , Ronquera/cirugía , Implantación de Prótesis Vascular/efectos adversos , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Arteria Subclavia/diagnóstico por imagen , Arteria Subclavia/cirugía , Accidente Cerebrovascular/etiología , Trombosis/cirugía , Aneurisma de la Aorta Torácica/cirugía
2.
Eur J Nucl Med Mol Imaging ; 51(8): 2260-2270, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38456972

RESUMEN

INTRODUCTION: Non-invasive detection of pathological changes in thoracic aortic disease remains an unmet clinical need particularly for patients with congenital heart disease. Positron emission tomography combined with magnetic resonance imaging (PET-MRI) could provide a valuable low-radiation method of aortic surveillance in high-risk groups. Quantification of aortic microcalcification activity using sodium [18F]fluoride holds promise in the assessment of thoracic aortopathies. We sought to evaluate aortic sodium [18F]fluoride uptake in PET-MRI using three methods of attenuation correction compared to positron emission tomography computed tomography (PET-CT) in patients with bicuspid aortic valve, METHODS: Thirty asymptomatic patients under surveillance for bicuspid aortic valve disease underwent sodium [18F]fluoride PET-CT and PET-MRI of the ascending thoracic aorta during a single visit. PET-MRI data were reconstructed using three iterations of attenuation correction (Dixon, radial gradient recalled echo with two [RadialVIBE-2] or four [RadialVIBE-4] tissue segmentation). Images were qualitatively and quantitatively analysed for aortic sodium [18F]fluoride uptake on PET-CT and PET-MRI. RESULTS: Aortic sodium [18F]fluoride uptake on PET-MRI was visually comparable with PET-CT using each reconstruction and total aortic standardised uptake values on PET-CT strongly correlated with each PET-MRI attenuation correction method (Dixon R = 0.70; RadialVIBE-2 R = 0.63; RadialVIBE-4 R = 0.64; p < 0.001 for all). Breathing related artefact between soft tissue and lung were detected using Dixon and RadialVIBE-4 but not RadialVIBE-2 reconstructions, with the presence of this artefact adjacent to the atria leading to variations in blood pool activity estimates. Consequently, quantitative agreements between radiotracer activity on PET-CT and PET-MRI were most consistent with RadialVIBE-2. CONCLUSION: Ascending aortic microcalcification analysis in PET-MRI is feasible with comparable findings to PET-CT. RadialVIBE-2 tissue attenuation correction correlates best with the reference standard of PET-CT and is less susceptible to artefact. There remain challenges in segmenting tissue types in PET-MRI reconstructions, and improved attenuation correction methods are required.


Asunto(s)
Aorta Torácica , Imagen por Resonancia Magnética , Imagen Multimodal , Humanos , Masculino , Femenino , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Imagen Multimodal/métodos , Aorta Torácica/diagnóstico por imagen , Adulto , Calcinosis/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Anciano , Válvula Aórtica/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos
3.
J Endovasc Ther ; : 15266028241256817, 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38817015

RESUMEN

BACKGROUND: Thrombotic material in the non-aneurysmatic and non-atherosclerotic aorta is a rare entity without any recommended standard treatment so far. We present a successful treatment strategy for patients who do not fit into any of the common approaches. CASE REPORT: A free-floating thrombus in the descending aorta was found as source of embolism in an 82-year-old female patient with lower limb ischemia. After initial heparinization of the patient without relevant reduction of the thrombotic mass, the thrombus was removed using an interdisciplinary approach. Under echocardiographic guidance to locate the thrombus, the AngioVac device, usually licensed to remove floating thrombi from the venous system, was used off-label to remove the thrombus by a transfemoral approach. To avoid rebuilding of a new thrombus, the attachment point with an exulcerated plaque in the descending aorta was covered by a stent graft via the same femoral access. The patient did not experience any further embolic events, and the postoperative course was uncomplicated. CONCLUSION: Patients with uncommon aortic diseases, such as the reported free-floating thrombus, should be treated by an individualized, interdisciplinary approach. Besides the recommended treatment options, there are other uncommon approaches that might offer an alternative in complex cases. CLINICAL IMPACT: Evidence is rare for the treatment of a free-floating thrombus in the descending aorta and the treatment strategy remains discussed controversially. We present a rather uncommon approach of successful off-label treatment for patients who do not fit into any of the common approaches (operative, endovascular, or conservative treatment based on patient's comorbidities). The AngioVac System has already been successfully used off-label in the arterial system but not in the above presented way of treating a free-floating thrombus in a patient with high embolization risk and treatment-limiting comorbidities.

4.
Arterioscler Thromb Vasc Biol ; 43(10): 1900-1920, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37589142

RESUMEN

BACKGROUND: Thoracic aortic dissection (TAD) is a life-threatening aortic disease without effective medical treatment. Increasing evidence has suggested a role for NE (neutrophil elastase) in vascular diseases. In this study, we aimed at investigating a causal role for NE in TAD and exploring the molecular mechanisms involved. METHODS: ß-aminopropionitrile monofumarate was administrated in mice to induce TAD. NE deficiency mice, pharmacological inhibitor GW311616A, and adeno-associated virus-2-mediated in vivo gene transfer were applied to explore a causal role for NE and associated target gene in TAD formation. Multiple functional assays and biochemical analyses were conducted to unravel the underlying cellular and molecular mechanisms of NE in TAD. RESULTS: NE aortic gene expression and plasma activity was significantly increased during ß-aminopropionitrile monofumarate-induced TAD and in patients with acute TAD. NE deficiency prevents ß-aminopropionitrile monofumarate-induced TAD onset/development, and GW311616A administration ameliorated TAD formation/progression. Decreased levels of neutrophil extracellular traps, inflammatory cells, and MMP (matrix metalloproteinase)-2/9 were observed in NE-deficient mice. TBL1x (F-box-like/WD repeat-containing protein TBL1x) has been identified as a novel substrate and functional downstream target of NE in TAD. Loss-of-function studies revealed that NE mediated inflammatory cell transendothelial migration by modulating TBL1x-LTA4H (leukotriene A4 hydrolase) signaling and that NE regulated smooth muscle cell phenotype modulation under TAD pathological condition by regulating TBL1x-MECP2 (methyl CpG-binding protein 2) signal axis. Further mechanistic studies showed that TBL1x inhibition decreased the binding of TBL1x and HDAC3 (histone deacetylase 3) to MECP2 and LTA4H gene promoters, respectively. Finally, adeno-associated virus-2-mediated Tbl1x gene knockdown in aortic smooth muscle cells confirmed a regulatory role for TBL1x in NE-mediated TAD formation. CONCLUSIONS: We unravel a critical role of NE and its target TBL1x in regulating inflammatory cell migration and smooth muscle cell phenotype modulation in the context of TAD. Our findings suggest that the NE-TBL1x signal axis represents a valuable therapeutic for treating high-risk TAD patients.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Disección de la Aorta Torácica , Animales , Humanos , Ratones , Aminopropionitrilo/toxicidad , Aneurisma de la Aorta Torácica/inducido químicamente , Aneurisma de la Aorta Torácica/genética , Aneurisma de la Aorta Torácica/metabolismo , Disección Aórtica/inducido químicamente , Disección Aórtica/genética , Elastasa de Leucocito/genética , Elastasa de Leucocito/efectos adversos
5.
Eur J Vasc Endovasc Surg ; 67(4): 584-592, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38145870

RESUMEN

OBJECTIVE: To evaluate outcomes in the follow up of thoracic endovascular aortic repair (TEVAR) vs. medical therapy in patients with acute type B aortic intramural haematoma (IMH). DATA SOURCES: The following sources were searched for articles meeting the inclusion criteria and published by July 2023: PubMed/MEDLINE, EMBASE, CENTRAL/CCTR (Cochrane Controlled Trials Register). REVIEW METHODS: This systematic review with pooled meta-analysis of time to event data followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) reporting guidelines, and its protocol was registered on the public platform PROSPERO (CRD42023456222). The following were analysed: overall survival (all cause mortality), aortic related mortality, and restricted mean survival time. Certainty of evidence was evaluated through the Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) tool. RESULTS: Eight studies met the eligibility criteria, including 1 015 patients (440 in the TEVAR group and 575 in the medical therapy group). All studies were observational, and the pooled cohort had a median follow up of 5.1 years. Compared with patients who received medical therapy alone, those who underwent TEVAR had a statistically significantly lower risk of all cause death (HR 0.44, 95% CI 0.30 - 0.65; p < .001; GRADE certainty: low), lower risk of aortic related death (HR 0.04, 95% CI 0.01 - 0.31; p = .002; GRADE certainty: low) and lifetime gain (restricted mean survival time was overall 201 days longer with TEVAR; p < .001). CONCLUSION: Thoracic endovascular aortic repair may be associated with lower risk of all cause and aortic related death compared with medical therapy in patients with acute type B IMH; however, the underlying data are not strong enough to draw robust clinical conclusions. Randomised controlled trials with large sample sizes and longer follow up are warranted to elucidate this question.


Asunto(s)
Aneurisma de la Aorta Torácica , Enfermedades de la Aorta , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Hematoma Intramural Aórtico , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Procedimientos Endovasculares/métodos , Enfermedades de la Aorta/cirugía , Implantación de Prótesis Vascular/métodos , Hematoma/cirugía , Resultado del Tratamiento , Estudios Retrospectivos , Aneurisma de la Aorta Torácica/cirugía , Factores de Riesgo
6.
Can J Physiol Pharmacol ; 102(3): 206-217, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37909404

RESUMEN

Hypotensive influences of benzodiazepines and other GABAA receptor ligands, recognized in clinical practice, seem to stem from the existence of "vascular" GABAA receptors in peripheral blood vessels, besides any mechanisms in the central and peripheral nervous systems. We aimed to further elucidate the vasodilatatory effects of ligands acting through GABAA receptors. Using immunohistochemistry, the rat aortic smooth muscle layer was found to express GABAA γ2 and α1-5 subunit proteins. To confirm the role of "vascular" GABAA receptors, we investigated the vascular effects of standard benzodiazepines, midazolam, and flumazenil, as well as the novel compound MP-III-058. Using two-electrode voltage clamp electrophysiology and radioligand binding assays, MP-III-058 was found to have modest binding but substantial functional selectivity for α5ß3γ2 over other αxß3γ2 GABAA receptors. Tissue bath assays revealed comparable vasodilatory effects of MP-III-058 and midazolam, both of which at 100 µmol/L concentrations had efficacy similar to prazosin. Flumazenil exhibited weak vasoactivity per se, but significantly prevented the relaxant effects of midazolam and MP-III-058. These studies indicate the existence of functional GABAA receptors in the rat aorta, where ligands exert vasodilatory effects by positive modulation of the benzodiazepine binding site, suggesting the potential for further quest for leads with optimized pharmacokinetic properties as prospective adjuvant vasodilators.


Asunto(s)
Flumazenil , Midazolam , Animales , Ratas , Midazolam/farmacología , Flumazenil/farmacología , Benzodiazepinas/farmacología , Aorta , Receptores de GABA-A , Ácido gamma-Aminobutírico
7.
Vascular ; : 17085381241238041, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38452485

RESUMEN

OBJECTIVES: Repairing thoracic aortic aneurysms with endovascular aortic repair (TEVAR) is a safe and minimally invasive method with low morbidity and short postoperative recovery. We developed a novel method to treat descending thoracic aortic aneurysms using a mini-thoracotomy approach in complex patients with difficult access. METHODS: A 56-year-old male patient presented with a 3-day history of chest pain. His past surgical history included infrarenal aortic ligation and right axillobifemoral bypass. Thoracic computed tomography angiography (CTA) revealed a saccular aortic aneurysmal dilatation at zone 2 measuring 4.4 × 4 cm. Owing to his surgical history, vascular access through the femoral and iliac arteries or abdominal aorta was impossible. We developed a new technique using a left posterolateral mini-thoracotomy approach to gain vascular access and perform TEVAR, avoiding the need for an open thoracotomy repair. RESULTS AND CONCLUSIONS: Thoracic CTA performed before discharge revealed complete aneurysmal exclusion and no endoleaks. Postoperative follow-up CTA (6 months and annually thereafter) revealed no aneurysm formation or aortic restenosis. The femoral artery, followed by the iliac artery, is the traditional access route for TEVAR. Left posterolateral mini-thoracotomy may be required as an alternative access in complex patients.

8.
Vascular ; : 17085381241236575, 2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38391289

RESUMEN

INTRODUCTION: Thoracic aortic aneurysms (TAAs) are an increasingly prevalent pathology with significant associated morbidity and mortality. Thoracic endovascular aortic repair (TEVAR) is the primary line of treatment. The purpose of this study was to analyse a single center's experience in the treatment of TAAs and identify possible risk factors for worse outcomes. METHODS: A retrospective review of our institutional database was done to identify all patients treated for TAAs in a 10-year period, from 1 January 2012 to 31 December 2022. Data were extracted from patients' medical records. Primary outcome was all-cause mortality and secondary outcomes were procedure related morbidity (vascular access complications, medullary ischaemia, stroke, endoleaks, migration, aneurysm sac enlargement >5 mm) and need for reintervention at 1-, 6- and 12-month follow-up. A descriptive and inferential analysis of the data was performed. Statistical analyses were conducted using the IBM Statistical Package for Social Sciences (SPSS) software. RESULTS: We identified 34 patients treated for TAAs in this period. Mean age was 68 years [47-87] and 79.4% of patients were male. Mean aneurysm diameter was 63 mm [35-100], 55.9% fusiform and 44.1% saccular. The majority (91.2%) were located at the descending thoracic aorta and 3 (8.8%) of them extended to the aortic arch. The most common aetiology was degenerative in 22 patients (64.7%), followed by aortic dissection in 8 patients (23.5%). Elective surgery was performed in 19 (61.3%) patients and 12 (38.7%) had urgent repair. TEVAR was the treatment of choice in 24 (77.4%) patients, and the remaining 7 (22.6%) were treated with hybrid surgery. Mean length of hospital stay was 10 days [2-80] (6 days for elective repair versus 16 days for urgent repair, p = .016). Follow-up period ranged from 1 month to 10 years. At 1 year follow-up, all-cause mortality was 15%, morbidity was 30% (with 6 (22%) patients having a type Ia endoleak) and need for reintervention was 22%. Aneurysm diameter was a significant risk factor for procedure related morbidity (median diameter of 73.5 mm versus 56.0 mm in patients with no morbidity; p = .027). The presence of type Ia endoleak was significantly associated with higher reintervention rates (p = .001), but not with higher mortality rates (p = .515). Age, female sex, aetiology and urgent repair weren't associated with any significant differences in the outcomes. CONCLUSIONS: TEVAR proved to be effective in the treatment of TAAs, with good outcomes at short and mid-term follow-up. TAAs should be diagnosed earlier and be promptly treated when meeting criteria to prevent worse outcomes.

9.
Emerg Radiol ; 31(2): 269-276, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38236521

RESUMEN

Non-traumatic thoracic aorta emergencies are acute conditions associated with substantial morbidity and mortality. In the emergency setting, timely detection of aortic injury through radiological imaging is crucial for prompt treatment planning and favorable patient outcomes. 3D cinematic rendering (CR), a novel rendering algorithm for computed tomography (CT) image processing, allows for life-like visualization of spatial details and contours of highly complex anatomic structures such as the thoracic aorta and its vessels, generating a photorealistic view that not just adds to diagnostic confidence, but is especially useful for non-radiologists, including surgeons and emergency medicine physicians. In this pictorial review, we demonstrate the utility of CR in the setting of non-traumatic thoracic aorta emergencies through 10 cases that were processed at a standalone 3D CR station at the time of presentation, including its role in diagnosis and management.


Asunto(s)
Aorta Torácica , Lesiones del Sistema Vascular , Humanos , Aorta Torácica/diagnóstico por imagen , Urgencias Médicas , Imagenología Tridimensional/métodos , Tomografía Computarizada por Rayos X/métodos
10.
Medicina (Kaunas) ; 60(4)2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38674307

RESUMEN

Background and objectives: The relationship between cerebral perfusion and new postoperative ischemic stroke in obese patients is not well defined. The aim of this study was to investigate the association between selective bilateral anterograde cerebral perfusion and new postoperative ischemic stroke in obese patients with emergency surgery for acute type A aortic dissection. Materials and methods: A total of 292 patients with emergency surgery for acute type A aortic dissection were included in this study. Patients with hemorrhagic stroke or ischemic stroke with severe neurological dysfunction at admission that were not candidates for surgery; patients who died in the first 48 h after intensive care admission and patients with incomplete medical records were excluded. Results: The mean age was 59.42 ± 10.68 years and the mean Euroscore was 9.12 ± 1.63. Obesity was present in 76.4%, the incidence of new postoperative ischemic stroke was 27.5%, and the postoperative mortality rate was 26.7%. The mean cardiopulmonary bypass time was 206.81 ± 75.48 min, the aortic cross-clamp time was 118.2 ± 46.42 min, and 90% of cases required cerebral perfusion. The mean cerebral perfusion time was 30.8 ± 24.41 min. Obese patients had a higher frequency of in-hospital death (p = 0.009), smoking (p = 0.036), hypertension (p = 0.023), left common carotid artery dissection (p < 0.001), right common carotid artery dissection (p = 0.029), femoral artery cannulation (p = 0.026), aortic root replacement (p = 0.009), aortic valve replacement (p = 0.005) and early reintervention for bleeding (p = 0.004). Using logistic regression, selective bilateral anterograde cerebral perfusion over 40 min in obese patients was independently associated with new postoperative ischemic stroke (OR = 2.35; 95%CI = 1.36-4.86; p = 0.021). Conclusions: A patient-tailored strategy for cerebral perfusion should be considered in obese patients, considering the high atheromatous burden of the supra-aortic vessels in these patients and the potential risk of atheromatous embolization associated with this technique.


Asunto(s)
Disección Aórtica , Accidente Cerebrovascular Isquémico , Obesidad , Complicaciones Posoperatorias , Humanos , Masculino , Persona de Mediana Edad , Femenino , Disección Aórtica/cirugía , Disección Aórtica/complicaciones , Disección Aórtica/fisiopatología , Obesidad/complicaciones , Anciano , Accidente Cerebrovascular Isquémico/etiología , Accidente Cerebrovascular Isquémico/complicaciones , Complicaciones Posoperatorias/etiología , Circulación Cerebrovascular/fisiología , Estudios Retrospectivos , Factores de Riesgo , Perfusión/métodos , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/fisiopatología
11.
Morphologie ; 108(362): 100779, 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38608628

RESUMEN

BACKGROUND: One of the most recent hormones to be identified and isolated is irisin, extracted from mouse skeletal muscle in 2012. Irisin has been proven to alter blood pressure, which has an impact on blood vessels, enhance endothelial functions, and prevent injury to endothelial cells. The current study aimed to study the effect of irisin on the ultrastructure of the rat thoracic aorta using the transmission electron microscope (TEM). MATERIALS AND METHODS: Twenty female rats were recruited for this study and divided into a control group (non-injected), and four experimental groups (injected groups) each consisting of 4 rats. The experimental groups were injected intraperitoneally with different doses of irisin (250ng/mL, 500ng/mL, 1000ng/mL, and 2000ng/mL) twice a week for 4weeks. Then, the descending thoracic aorta of all experimental rats were resected and proceeded with imaging. RESULTS: The results of this study showed a change in the thickness of the tunica intima, internal elastic lamina, elastic lamellae, and external elastic lamina concerning increasing injected irisin concentration. While there was a significant increase in the thickness of tunica media (P<0.0001) and smooth muscle cells (P<0.05). Also, the results showed a significant increase in the number of elastic lamellae in the tunica media (P<0.0001). CONCLUSION: Irisin had a major impact on the elasticity of the rat thoracic aorta wall, suggesting that it influences the growth factors of the wall and activates smooth muscle cells in addition to endothelial cells.

12.
J Vasc Surg ; 78(2): 540-547.e4, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36754248

RESUMEN

OBJECTIVE: To investigate the long-term reinterventions of thoracic endovascular repair (TEVAR) after blunt traumatic aortic injury. METHODS: MEDLINE, EMBASE, and Cochrane databases were interrogated until June 2021. Inclusion criteria were blunt traumatic aortic injury treated with TEVAR and mean follow-up of more than 60 months. A systematic review was conducted and data were pooled using a random effects model of proportions applying the Freeman-Tukey transformation. Late reintervention was the primary outcome. Secondary outcomes were procedure-related complications (endoleak, in-stent thrombosis, occlusion, infolding/collapse, bird-beak, migration, and left arm claudication), overall and aortic-related mortality, and aortic diameter changes. RESULTS: Eleven studies with a low quality assessment were included. Four hundred eight patients were collected and the 389 surviving more than 30 days were included. The mean follow-up was 8.2 years (95% confidence interval [CI], 5.7-10.8; I2 = 40.2%). Late reintervention was 2.1% (95% CI, 0.6-3.9; I2 = 0.0%; 11/389 cases) with 0.1% (95% CI, 0.0-1.2; I2 = 0.0%; 3/389) occurring after 5 years. Bird-beak was identified in 38.7% (95% CI, 16.4-63.6; I2 = 86.6%). Left arm claudication occurring after 30 days was 3.1% (95% CI, 0.1-8.6; I2 = 26.9%; 11/140 cases). In-stent thrombosis was 1.9% (95% CI, 0.1-5.2; I2 = 51.8%; 11/389 cases). Endoleak was 0.5% (95% CI, 0.0-1.9; I2 = 0.0%; 5/389 cases). Infolding, occlusion, and migration were reported in 2 of 389, 1 of 389, and 0 of 389 patients, respectively. Overall late survival was 95.6% (95% CI, 88.1-99.8; I2 = 84.7%; 358/389 patients) and only one patient accounted for aortic related mortality. The increase in proximal and distal aortic diameters was estimated at 2.7 mm (95% CI, 1.2-4.3; I2 = 0.0%) and 2.5 mm (95% CI, 1.1-3.9; I2 = 0.0%), respectively. CONCLUSIONS: TEVAR demonstrates remarkably good long-term results and reinterventions are rarely required. Aortic reinterventions tend to occur within the first and after the fifth year.


Asunto(s)
Implantación de Prótesis Vascular , Procedimientos Endovasculares , Heridas no Penetrantes , Humanos , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aorta Torácica/lesiones , Stents/efectos adversos , Endofuga/etiología , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Estudios Retrospectivos , Heridas no Penetrantes/diagnóstico por imagen , Heridas no Penetrantes/cirugía , Heridas no Penetrantes/complicaciones
13.
J Vasc Surg ; 78(6): 1402-1408.e1, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37454954

RESUMEN

OBJECTIVE: This article reports on a retrospective observational study designed to evaluate the incidence, etiology, and clinical implications of aortic neck dilation following thoracic endovascular aortic repair (TEVAR) for aneurysms with landing zones II and III. METHODS: The study included 37 patients who underwent TEVAR and had postoperative computed tomography angiography available within 30 days and at least one computed tomography angiography at 1 year postoperatively. The primary end point was proximal aortic dilation (defined as growth ≥5 mm or ≥10% of the original diameter), and secondary end points included annual growth of the aneurysmal sac, device migration, endoleak, and reintervention with additional neck-related adverse events. The measurements taken during follow-up included the maximum diameter of the aneurysm and aortic diameter at various locations relative to the stent graft. RESULTS: During follow-up, a significant increase in aortic diameter was observed at the proximal edge of TEVAR. The estimated freedom from 5 mm or 10% proximal aortic neck growth at 1, 2, and 3 years was 81%, 70%, and 65%, respectively. At the proximal edge of TEVAR the type III aortic arch was significantly associated with 5 mm growth during follow-up (P = .047) and this growth (5 mm or 10%) as well as a 10% increase at +20 mm were significantly associated with more aortic-related reinterventions. Moreover, an aortic diameter at the start <36 mm was associated with a greater increase during follow-up (area under curve in receiver operating characteristic >80%; P < .05). CONCLUSIONS: The study concludes that proximal aortic dilation after TEVAR is a common and progressive phenomenon, and the management strategies for aortic neck dilation, including surveillance, secondary interventions, and open conversion, should be considered carefully to optimize patient outcomes and improve the long-term success of the procedure.


Asunto(s)
Enfermedades de la Aorta , Reparación Endovascular de Aneurismas , Humanos , Angiografía , Aorta , Dilatación , Estudios Retrospectivos
14.
Eur Radiol ; 33(3): 1687-1697, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36269370

RESUMEN

OBJECTIVES: To compare the accuracy and precision of 3D-Dixon and 2D-SSFP MR-imaging for assessment of aortic diameter in Marfan patients. METHODS: This prospective single-center study investigated respiratory-gated 3D-Dixon and breath-hold 2D-SSFP non-contrast MR-imaging at 3 T in 47 Marfan patients (36.0 ± 13.2 years, 28♀,19♂). Two radiologists performed individual diameter measurements at five levels of the thoracic aorta and evaluated image quality on a four-grade scale (1 = poor, 4 = excellent) and artifacts (1 = severe, 4 = none). Aortic root diameters acquired by echocardiography served as a reference standard. Intraclass correlation coefficient, Bland-Altman analyses, F-test, t-test, and regression analyses were used to assess agreement between observers and methods. RESULTS: Greatest aortic diameters were observed at the level of the sinuses of Valsalva (SOV) for 3D-Dixon (38.2 ± 6.8 mm) and 2D-SSFP (38.3 ± 7.1 mm) (p = 0.53). Intra- and interobserver correlation of diameter measurements was excellent at all aortic levels for both 3D-Dixon (r = 0.94-0.99 and r = 0.94-0.98) and 2D-SSFP (r = 0.96-1.00 and r = 0.95-0.99). 3D-Dixon-derived and 2D-SSFP-derived diameter measurements at the level of the SOV revealed a strong correlation with echocardiographic measurements (r = 0.92, p < 0.001 and r = 0.93, p < 0.001, respectively). The estimated mean image quality at the level of SOV was higher for 2D-SSFP compared to that for 3D-Dixon (3.3 (95%-CI: 3.1-3.5) vs. 2.9 (95%-CI: 2.7-3.1)) (p < 0.001). Imaging artifacts were less at all aortic levels for 3D-Dixon compared to 2D-SSFP (3.4-3.8 vs. 2.8-3.1) (all p < 0.002). CONCLUSION: Respiratory-gated 3D-Dixon and breath-hold 2D-SSFP MR-imaging provide accurate and precise aortic diameter measurements. We recommend 3D-Dixon imaging for monitoring of aortic diameter in Marfan patients due to fewer imaging artifacts and the possibility of orthogonal multiplanar reformations of the aortic root. KEY POINTS: • Respiratory-gated 3D-Dixon and breath-hold 2D-SSFP imaging provide accurate and precise aortic diameter measurements in patients suffering from Marfan syndrome. • Imaging artifacts are stronger in 2D-SFFP imaging than in 3D-Dixon imaging. • We recommend 3D-Dixon imaging for monitoring of aortic diameter in Marfan patients due to fewer imaging artifacts and the possibility of orthogonal multiplanar reformations.


Asunto(s)
Síndrome de Marfan , Humanos , Síndrome de Marfan/diagnóstico por imagen , Estudios Prospectivos , Angiografía por Resonancia Magnética/métodos , Medios de Contraste , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados
15.
Eur Radiol ; 33(7): 4962-4972, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36692595

RESUMEN

OBJECTIVES: To compare between the diagnostic performance of 3.0-T MRI and CT for aorta and tracheobronchial invasion in patients with esophageal cancer (EC). METHODS: We prospectively included patients with pathologically confirmed EC from November 2018 to June 2021, who had baseline stage of T3-4N0-2M0 and restaging after neoadjuvant chemotherapy. All patients underwent contrast-enhanced CT and MRI of the thorax. Two independent blinded radiologists scored image quality and the presence of invasion. Agreements between the two readers were calculated using kappa test. The sensitivity, specificity, accuracy, positive predict value (PPV), and negative predict value (NPV) of MRI and CT in evaluating invasion were calculated. The net reclassification index (NRI) was used to evaluate the change in the number of patients correctly classified by MRI and CT. RESULTS: A total of 70 patients (64.8 ± 9.0 years; 53 men) were enrolled. Inter-reader agreements of image quality scores and presence of invasion by MRI and CT between the two readers were almost perfect (kappa > 0.80). The accuracy of MRI in evaluating thoracic aorta invasion was significantly higher than that of CT (reader 1: 90.0% vs. 71.4%; reader 2: 92.9% vs. 70.0%, respectively), and the accuracy of MRI in evaluating tracheobronchial invasion also was significantly higher than that of CT (reader 1: 92.9% vs. 72.9%; reader 2: 95.7% vs. 70.0%, respectively). NRI values were positive in both the evaluation of aorta and tracheobronchial invasion. CONCLUSIONS: The accuracy of 3-T MRI in determining thoracic aorta and tracheobronchial invasion is significantly higher than that of CT. KEY POINTS: • 3.0-T MRI was significantly more accurate than CT in assessing invasion of the thoracic aorta in patients with esophageal cancer. • 3.0-T MRI was also significantly more accurate than CT in assessing tracheobronchial invasion in patients with esophageal cancer. • 3.0-T MRI has a higher diagnostic performance than CT in evaluating patients with suspected aortic or tracheobronchial invasion in esophageal cancer.


Asunto(s)
Neoplasias Esofágicas , Masculino , Humanos , Neoplasias Esofágicas/diagnóstico por imagen , Neoplasias Esofágicas/tratamiento farmacológico , Aorta/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Imagen por Resonancia Magnética/métodos , Sensibilidad y Especificidad
16.
J Endovasc Ther ; 30(1): 84-90, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35114844

RESUMEN

PURPOSE: Surgical treatment of primary lung T4 tumors is controversial especially when the cancer invades the mediastinal structures or the descending thoracic aorta. Conventional surgical treatment is associated with a high perioperative mortality and morbidity rate. Thoracic EndoVascular Aortic Repair has emerged as a valid off-label alternative to conventional surgery. We aimed to assess perioperative and midterm aortic-related outcome of patients who have undergone aortic stent-graft implantation, followed by en bloc surgical treatment of the involved aorta and lung cancer resection. MATERIALS AND METHODS: From July 2017 to May 2020, we treated 5 patients diagnosed with a T4 lung cancer by the involvement of the descending thoracic aorta. When only the descending thoracic aorta is involved, a 2-stage procedure was considered, with aortic stent-graft implantation performed before tumor resection. One-stage strategy, with stent-graft implantation carried out before thoracotomy, was preferred for patients with the involvement of cardiac and/or other vascular mediastinal structures. RESULTS: The mean age was 58.4 ± 6.2 years. All patients were affected by non-small cell lung cancer. All 5 patients required a single stent-graft to completely cover the involved segment of aorta. Four patients underwent a 2-stage procedure. One patient, with the involvement of the left inferior pulmonary vein, required a 1-stage en bloc resection of the left lower lobe, aortic wall adventitia, left inferior pulmonary vein, and reconstruction of the left atrial wall. Primary procedural success was achieved in all. At follow-up, no patient developed aortic-related complications. One patient died 2 years after surgery, due to local recurrence of the tumor. CONCLUSION: T4 lung resection combined with aortic stent-graft implantation can be safely performed. Endovascular surgery, by avoiding the use of cardiopulmonary bypass, aortic cross-clamping, and graft replacement, can reduce significant morbidity and mortality rate. Postoperative and long-term outcome of these patients treated with endovascular surgery is mainly related to pulmonary disease, not to aortic treatment.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Carcinoma de Pulmón de Células no Pequeñas , Procedimientos Endovasculares , Neoplasias Pulmonares , Humanos , Persona de Mediana Edad , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugía , Neoplasias Pulmonares/etiología , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Carcinoma de Pulmón de Células no Pequeñas/complicaciones , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Stents/efectos adversos , Complicaciones Posoperatorias/etiología , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos
17.
J Endovasc Ther ; : 15266028231161489, 2023 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-36960843

RESUMEN

PURPOSE: To analyze the learning curve for thoracic endovascular aortic repair (TEVAR) in a single center over a period of 25 years. MATERIALS AND METHODS: In total, 390 consecutive standard TEVAR procedures undertaken between 1996 and 2021 were included in a retrospective, observational, single-center study. Cumulative sum charts were elaborated for the entire center experience (primary outcome) as well as for the first and second implanting physicians. Data on procedural variables (contrast volume, operative and fluoroscopy time), 30-day major adverse events (MAEs) and clinical success, and endoleak and reintervention rates were secondary outcomes and subdivided into 4 quartiles of experience (Q1-Q4) or presented as first 2 versus latest 2 quartiles (Q1-Q2 vs Q3-Q4). RESULTS: The mean follow-up was 4.3±4.0 years. The center's learning curve was achieved after 75 procedures, and it was similar for the first implanting physician. The surgeon coming thereafter had a significantly shorter curve (10 TEVARs). Comparing Q1-Q2 with Q3-Q4, 30-day MAEs (16.1 vs 11.3%, p=0.164), 30-day mortality (11.4% vs 3.6%, p=0.003), and intraoperative additional maneuvers (21.5% vs 13.3%, p=0.033) were reduced along with an improvement in clinical success (85.9% vs 90.3%, p=0.190). From Q1 to Q4, operative time (139.8±65.5 to 76.7±43.7 min, p=0.001), fluoroscopy time (15.1±8.8 to 7.1±5.1 min, p<0.001), and contrast volume (244.0±112.1 to 104.3±46.1 mL, p<0.001) showed a considerable reduction. Late endoleak and aortic-related mortality declined significantly from Q1-Q2 to Q3-Q4 (24.1% to 15.5%, p=0.033 and 18.6% vs 8.2%, p=0.006, respectively). Operative time (p=0.021), contrast volume (p=0.016), and fluoroscopy time (p=0.004) were independent risk factors for endoleak, causing a 1.3-fold risk increase for both each 60 minutes of additional operative time (p=0.021) and every 100 mL of additional contrast medium (p=0.016). Each 10-minute increase in fluoroscopy time determined a 1.4-fold risk increment (p=0.004). CONCLUSION: The learning curve shortened significantly over time with non-negligible clinical outcome improvements, suggesting that specific endovascular training is mandatory to become an effective TEVAR performer. CLINICAL IMPACT: For the first time in literature, the standard TEVAR's learning curve has been evaluated at a single vascular surgery center over a period of 25 years. The learning curve for the center and the first physician historically undertaking TEVAR was achieved at the 75th treated patient. The learning curve of the surgeons coming thereafter was significantly shorter (10 cases). This quarter-century demonstrated that intraoperative learning-related variables were associated with long-term clinical outcomes and all have improved over time. Centers approaching TEVAR for the first time and training program providers could use these data to aim to offer better clinical outcomes.

18.
J Endovasc Ther ; : 15266028231206996, 2023 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-37872769

RESUMEN

PURPOSE: For aortic coarctation in adults endovascular repair is the treatment of choice with an acceptable safety profile. Aortic isthmus atresia is a related condition with a complete occlusion of the aorta not allowing catheterization across the isthmus. This technical note describes a recanalization of an aortic isthmus atresia using radiofrequency with an "electrified wire technique." TECHNIQUE: A guidewire was selectively denuded of PTFE (polytetrafluoroethylene) at the distal end and was placed through a catheter distal to the aortic isthmus atresia. The denuded end of the wire was clamped to an electrosurgery pencil. By pushing the wire toward a tulip-snare, which was placed as a target proximal of the occlusion via left trans-brachial access, and shortly activating of the electrosurgery pencil the electrified wire recanalized the occlusion and was snared and used to guide implantation of a balloon-expandable covered stent. CONCLUSION: The electrified wire puncture technique can be used to recanalize adult aortic isthmus atresia after failed conventional attempts. CLINICAL IMPACT: The electrified wire technique offers an off-the shelf option to modify standard guidewires for the use with radiofrequency to cross a complete aortic isthmus occlusion after failed conventional attempts. This new technique may be applied also in other situations like dissection flap fenestration, transcaval access and similar.

19.
J Endovasc Ther ; 30(1): 38-44, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35018867

RESUMEN

PURPOSE: The objective of this study is to describe a novel method for creating a distal landing zone for thoracic endovascular aortic repair (TEVAR) in chronic aortic dissection. The technique is described in a patient with prior total arch and descending aortic replacement, with false lumen expansion. TECHNIQUE: A cheese-wire endovascular septotomy was desired to create a single lumen above the celiac axis. To avoid dividing the septum caudally across the visceral segment, we performed a modified septotomy in a cephalad direction. Stiff wires were passed into the prior surgical graft, through true lumen on the right and false lumen on the left. An additional wire was passed across an existing fenestration at the level of the celiac axis, and snared and externalized. 7F Ansel sheaths were advanced and positioned tip-to-tip at the fenestration. Using the stiff wires as tracks, the through-wire was pushed cephalad to endovascularly cut the septum. Angiogram demonstrated successful septotomy, and TEVAR was performed to just above the celiac with successful aneurysm exclusion and no endoleak or retrograde false lumen perfusion. Follow-up computed tomography angiogram (CTA) showed continued exclusion without false lumen perfusion. CONCLUSIONS: This novel modification in a reverse direction provides an alternative method for endovascular septotomy, when traditional septotomy may threaten the visceral vessels.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Reparación Endovascular de Aneurismas , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Stents , Estudios Retrospectivos , Prótesis Vascular
20.
J Endovasc Ther ; : 15266028231158971, 2023 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-36891635

RESUMEN

PURPOSE: The purpose of the study was to evaluate the midterm and long-term outcomes of patients who underwent thoracic endovascular aortic repair (TEVAR) procedure to treat an uncomplicated acute and subacute type B aortic dissection (uATBAD) with high risk for subsequent aortic complications compared with the group of patients who received a conservative treatment protocol during the same period. MATERIALS AND METHODS: Between 2008 and 2019, 35 patients who had TEVAR due to uATBAD and those with conservative procedure (n=18) were included in a retrospective analysis and follow-up study. The primary endpoints were false lumen thrombosis/perfusion, true lumen diameter, and aortic dilatation. The aortic-related mortality, reintervention, and long-term survival were the secondary endpoints. RESULTS: In the study period, 53 patients (22 females) with a mean age of 61.1±13 years were included. No 30-day and in-hospital mortality was recorded. Permanent neurological deficits occurred in 2 patients (5.7%). In the TEVAR group (n=35) and in a median follow-up period of 34 months, a significant reduction of maximum aortic and false lumen diameter as well as a significant increase of true lumen diameter were detected (p<0.001 each). Complete false lumen thrombosis increased from 6% preoperatively to 60% at follow-up. The median difference in aortic, false lumen, and true lumen diameter was -5 mm (interquartile range [IQR]=-28 to 8 mm), -11 mm (IQR=-53 to 10 mm), and 7 mm (IQR=-13 to 17 mm), respectively. In 3 patients (8.6%), a reintervention was needed. Two patients (1 aortic-related) died during follow-up. The estimated survival according to Kaplan-Meyer analysis was 94.1% after 3 years and 87.5% after 5 years. Similar to the TEVAR group, no 30-day or in-hospital mortality was recorded in the conservative group. During follow-up, 2 patients died and 5 patients underwent conversion-TEVAR (28%). In a median follow-up period of 26 months (range=150), a significant increase of maximum aortic diameter (p=0.006) and a tendency to augmentation of the false lumen (p=0.06) were noted. No significant reduction of the true lumen was seen. CONCLUSIONS: Thoracic endovascular aortic repair in patients at high risk of subsequent aortic complications in uncomplicated acute and subacute type B aortic dissection is safe and is associated with favorable midterm outcomes regarding aortic remodeling. CLINICAL IMPACT: In a retrospective, single center analysis of prospectively collected data with follow-up, we compared 35 patients with high-risk features who recieved TEVAR in acute and sub-acute uncomplicated type B aortic dissection to a control-group (n=18). The TEVAR group showed a significant positive remoduling (reduction of max. aortic and false lumen diameter and increase of true lumen diameter (p<0.001 each)) during follow-up with an estimated survival of 94.1% after 3 years and 87.5% after 5 years.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA