RESUMEN
Tricuspid valve disease is an often underrecognized clinical problem that is associated with significant morbidity and mortality. Unfortunately, patients will often present late in their disease course with severe right-sided heart failure, pulmonary hypertension, and life-limiting symptoms that have few durable treatment options. Traditionally, the only treatment for tricuspid valve disease has been medical therapy or surgery; however, there have been increasing interest and success with the use of transcatheter tricuspid valve therapies over the past several years to treat patients with previously limited therapeutic options. The tricuspid valve is complex anatomically, lying adjacent to important anatomic structures such as the right coronary artery and the atrioventricular node, and is the passageway for permanent pacemaker leads into the right ventricle. In addition, the mechanism of tricuspid pathology varies widely between patients, which can be due to primary, secondary, or a combination of causes, meaning that it is not possible for 1 type of device to be suitable for treatment of all cases of tricuspid valve disease. To best visualize the pathology, several modalities of advanced cardiac imaging are often required, including transthoracic echocardiography, transesophageal echocardiography, cardiac computed tomography, and cardiac magnetic resonance imaging, to best visualize the pathology. This detailed imaging provides important information for choosing the ideal transcatheter treatment options for patients with tricuspid valve disease, taking into account the need for the lifetime management of the patient. This review highlights the important background, anatomic considerations, therapeutic options, and future directions with regard to treatment of tricuspid valve disease.
Asunto(s)
American Heart Association , Válvula Tricúspide , Humanos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/patología , Estados Unidos , Enfermedades de las Válvulas Cardíacas/terapia , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/terapia , Implantación de Prótesis de Válvulas CardíacasRESUMEN
BACKGROUND: This study aimed to compare the incidence and prognostic implications of new-onset conduction disturbances after surgical aortic valve replacement (SAVR) in patients with bicuspid aortic valve (BAV) aortic stenosis (AS) versus patients with tricuspid aortic valve (TAV) AS (ie, BAV-AS and TAV-AS, respectively). Additionally, the study included stratification of BAV patients according to subtype. METHODS: In this cohort study, the incidence of postoperative third-degree atrioventricular (AV) block with subsequent permanent pacemaker requirement and new-onset left bundle-branch block (LBBB) was investigated in 1147 consecutive patients without preoperative conduction disorder who underwent isolated SAVR (with or without ascending aortic surgery) between January 1, 2005, and December 31, 2022. The groups were stratified by aortic valve morphology (BAV, n=589; TAV, n=558). The outcomes of interests were new-onset third-degree AV block or new-onset LBBB during the index hospitalization. The impact of new-onset postoperative conduction disturbances on survival was investigated in BAV-AS and TAV-AS patients during a median follow-up of 8.2 years. BAV morphology was further categorized according to the Sievers and Schmidtke classification system (possible in 307 BAV-AS patients) to explore association between BAV subtypes and new-onset conduction disturbances after SAVR. RESULTS: The overall incidence of third-degree AV block and new-onset LBBB after SAVR was 4.5% and 7.8%, respectively. BAV-AS patients had a higher incidence of both new-onset third-degree AV block (6.5% versus 2.5%; P=0.001) and new-onset LBBB (9.7% versus 5.7%; P=0.013) compared with TAV-AS patients. New-onset LBBB was associated with an increased all-cause mortality during follow-up (adjusted hazard ratio, 1.60 [95% CI, 1.12-2.30]; P=0.011), whereas new-onset third-degree AV block was not associated with worse prognosis. Subgroup analysis of the BAV cohort revealed that BAV-AS patients with fusion of the right- and non-coronary cusps had the highest risk of new-onset third-degree AV block (adjusted odds ratio [aOR], 8.33 [95% CI, 3.31-20.97]; P<0.001, with TAV as reference group) and new-onset LBBB (aOR, 4.03 [95% CI, 1.84-8.82]; P<0.001, with TAV as reference group), whereas no significant association was observed for the other BAV subtypes. CONCLUSIONS: New-onset LBBB after SAVR is associated with increased all-cause mortality during follow-up, and is more frequent complication in BAV AS patients compared with TAV-AS patients. BAV-AS patients with fusion of the right- and non-coronary cusps have an increased risk for conduction disturbances after SAVR. This should be taken into consideration when managing these patients.
RESUMEN
Atrial secondary tricuspid regurgitation (A-STR) is a distinct phenotype of secondary tricuspid regurgitation with predominant dilation of the right atrium and normal right and left ventricular function. Atrial secondary tricuspid regurgitation occurs most commonly in elderly women with atrial fibrillation and in heart failure with preserved ejection fraction in sinus rhythm. In A-STR, the main mechanism of leaflet malcoaptation is related to the presence of a significant dilation of the tricuspid annulus secondary to right atrial enlargement. In addition, there is an insufficient adaptive growth of tricuspid valve leaflets that become unable to cover the enlarged annular area. As opposed to the ventricular phenotype, in A-STR, the tricuspid valve leaflet tethering is typically trivial. The A-STR phenotype accounts for 10%-15% of clinically relevant tricuspid regurgitation and has better outcomes compared with the more prevalent ventricular phenotype. Recent data suggest that patients with A-STR may benefit from more aggressive rhythm control and timely valve interventions. However, little is mentioned in current guidelines on how to identify, evaluate, and manage these patients due to the lack of consistent evidence and variable definitions of this entity in recent investigations. This interdisciplinary expert opinion document focusing on A-STR is intended to help physicians understand this complex and rapidly evolving topic by reviewing its distinct pathophysiology, diagnosis, and multi-modality imaging characteristics. It first defines A-STR by proposing specific quantitative criteria for defining the atrial phenotype and for discriminating it from the ventricular phenotype, in order to facilitate standardization and consistency in research.
Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/complicaciones , Atrios Cardíacos/diagnóstico por imagen , Válvula Tricúspide/diagnóstico por imagen , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/terapiaRESUMEN
PURPOSE: Tricuspid valve flow velocities are challenging to measure with cardiovascular MR, as the rapidly moving valvular plane prohibits direct flow evaluation, but they are vitally important to diastolic function evaluation. We developed an automated valve-tracking 2D method for measuring flow through the dynamic tricuspid valve. METHODS: Nine healthy subjects and 2 patients were imaged. The approach uses a previously trained deep learning network, TVnet, to automatically track the tricuspid valve plane from long-axis cine images. Subsequently, the tracking information is used to acquire 2D phase contrast (PC) with a dynamic (moving) acquisition plane that tracks the valve. Direct diastolic net flows evaluated from the dynamic PC sequence were compared with flows from 2D-PC scans acquired in a static slice localized at the end-systolic valve position, and also ventricular stroke volumes (SVs) using both planimetry and 2D PC of the great vessels. RESULTS: The mean tricuspid valve systolic excursion was 17.8 ± 2.5 mm. The 2D valve-tracking PC net diastolic flow showed excellent correlation with SV by right-ventricle planimetry (bias ± 1.96 SD = -0.2 ± 10.4 mL, intraclass correlation coefficient [ICC] = 0.92) and aortic PC (-1.0 ± 13.8 mL, ICC = 0.87). In comparison, static tricuspid valve 2D PC also showed a strong correlation but had greater bias (p = 0.01) versus the right-ventricle SV (10.6 ± 16.1 mL, ICC = 0.61). In most (8 of 9) healthy subjects, trace regurgitation was measured at begin-systole. In one patient, valve-tracking PC displayed a high-velocity jet (380 cm/s) with maximal velocity agreeing with echocardiography. CONCLUSION: Automated valve-tracking 2D PC is a feasible route toward evaluation of tricuspid regurgitant velocities, potentially solving a major clinical challenge.
Asunto(s)
Aprendizaje Profundo , Imagen por Resonancia Cinemagnética , Válvula Tricúspide , Humanos , Válvula Tricúspide/diagnóstico por imagen , Masculino , Femenino , Adulto , Imagen por Resonancia Cinemagnética/métodos , Velocidad del Flujo Sanguíneo , Persona de Mediana Edad , Diástole , Procesamiento de Imagen Asistido por Computador/métodos , Volumen Sistólico/fisiología , Interpretación de Imagen Asistida por Computador/métodos , Algoritmos , Reproducibilidad de los Resultados , Sístole/fisiologíaRESUMEN
INTRODUCTION: Four-dimensional (4D) intracardiac echocardiography (ICE) is a novel cardiac imaging modality that has been applied to various workflows, including catheter ablation, tricuspid valve repair, and left atrial appendage occlusion (LAAO). The use of this type of advanced ICE imaging may ultimately allow for the replacement of transesophageal echocardiography (TEE) for LAAO, providing comparable imaging quality while eliminating the need for general anesthesia. METHODS: Based on our initial clinical experience with 4D ICE in LAAO, we have developed an optimized workflow for the use of the NUVISION™ 4D ICE Catheter in conjunction with the GE E95 and S70N Ultrasound Systems in LAAO. In this manuscript, we provide a step-by-step guide to using 4D ICE in conjunction with compatible imaging consoles. We have also evaluated the performance of 4D ICE with the NUVISION Ultrasound Catheter versus TEE in one LAAO case and present those results here. RESULTS: In our comparison of 4D ICE using our optimized workflow with TEE in an LAAO case, ICE LAA measurements were similar to those from TEE. The best image resolution was seen via ICE in 2-dimensional and multislice modes (triplane and biplane). The FlexiSlice multiplanar reconstruction tool, which creates an en-face image derived from a 4D volume set, also provided valuable information but yielded slightly lower image quality, as expected for these volume-derived images. For this case, comparable images were obtained with TEE and ICE but with less need to reposition the ICE catheter. CONCLUSION: The use of optimized 4D ICE catheter workflow recommendations allows for efficient LAAO procedures, with higher resolution imaging, comparable to TEE.
Asunto(s)
Apéndice Atrial , Ecocardiografía Tetradimensional , Ecocardiografía Transesofágica , Flujo de Trabajo , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Valor Predictivo de las Pruebas , Cateterismo Cardíaco/instrumentación , Ultrasonografía Intervencional , MasculinoRESUMEN
Controversies continue regarding several aspects of the anatomy of the morphologically right ventricle. There is disagreement as to whether the ventricle should be assessed in bipartite or tripartite fashion, and the number of leaflets to be found in the tricuspid valve. In particular, there is no agreement as to whether a muscular outlet septum is present in the normally constructed heart, nor how many septal components are to be found during normal development. Resolving these issues is of potential significance to those investigating and treating children with congenitally malformed hearts. With all these issues in mind, we have revisited our own experience in investigating the development and morphology of the normal right ventricle. To assess development, we have examined a large number of datasets, prepared by both standard and episcopic microscopy, from human and murine embryos. In terms of gross anatomy, we have compared dissections of normal autopsied hearts with virtual dissections of datasets prepared using computed tomography. Our developmental and postnatal studies, taken together, confirm that the ventricle is best assessed in tripartite fashion, with the three parts representing its inlet, apical trabecular, and outlet components. The ventricular septum, however, has only muscular and membranous components. The muscular part incorporates a small component derived from the muscularised fused proximal outflow cushions, but this part cannot be distinguished from the much larger part that is incorporated within the free-standing muscular infundibular sleeve. We confirm that the tricuspid valve itself has three components, which are located inferiorly, septally, and antero-superiorly.
Asunto(s)
Cardiopatías Congénitas , Ventrículos Cardíacos , Niño , Humanos , Animales , Ratones , Ventrículos Cardíacos/anatomía & histología , Válvula Tricúspide , Microscopía , Tomografía Computarizada por Rayos XRESUMEN
Tricuspid regurgitation (TR) is the most common valvular pathology after heart transplantation (HTx) and endomyocardial biopsy (EMB) remains responsible for the majority of cases due to the high probability of structural valve damage. The aim of the present review was to describe the results of surgical management of severe tricuspid regurgitation through tricuspid valve replacement (TVR) after a previous HTx. A systematic review was conducted by searching Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane databases until June 2023 for publications reporting patients undergoing TVR surgery after a previous HTx. If no right heart valve surgery was undertaken, or a heterotopic heart transplant was performed, or if the concomitant procedure was performed during the transplant itself, the paper was excluded. Twenty articles met our inclusion criteria out of 1532 potentially eligible studies, with a total of 300 patients. Mean age was 55.1 ± 9.6 years, and 85.1% were male. The mean number of EMB per patient was 31.1 ± 5.5 with a mean time between HTx and TVR of 7.64 ± 3.31 years. Bioprostheses were used in 83.3% of cases and 75.0% of patients with a bioprosthesis were reported as alive at last follow-up. Tricuspid valve repair is a valuable option, but these patients will be susceptible to recurrent TR after EMB. TVR with a bioprosthesis may provide the optimal solution for this subset of patients, as EMB is not feasible with a mechanical valve.
Asunto(s)
Trasplante de Corazón , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Masculino , Persona de Mediana Edad , Femenino , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Válvula Tricúspide/cirugía , Resultado del Tratamiento , Estudios Retrospectivos , Prótesis Valvulares Cardíacas/efectos adversos , Trasplante de Corazón/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodosRESUMEN
Functional tricuspid regurgitation (FTR) is a common type of tricuspid regurgitation (TR), particularly in cases of left heart valve disease. Historically, cardiac surgeons have not placed much emphasis on FTR and instead focused primarily on managing left heart valve disease. However, as research has progressed, it has become evident that severe TR significantly impacts the prognosis of heart valve surgery. Furthermore, significant improvements in postoperative cardiac function and quality of life have been observed when addressing the tricuspid valve alongside left heart disease management. This article aims to review current approaches for and timing of the surgical management of FTR while also analyzing the limitations of existing tricuspid surgical strategies.
RESUMEN
Tricuspid regurgitation, once considered a relatively benign condition, has now gathered significant attention due to new evidence showing its impact on both short- and long-term follow-up. While surgical intervention remains the established standard approach for treating severe tricuspid regurgitation, current guidelines provide Class I indication for intervention in only a limited set of scenarios. This review delves into the present and future perspectives of surgical tricuspid regurgitation management, examining aspects such as disease prognosis, surgical indications, outcomes, and a comprehensive overview of past and upcoming clinical trials.
RESUMEN
A large proportion of patients referred for transcatheter tricuspid valve intervention (TTVI) will have the presence of a cardiac implantable electronic device (CIED). In such patients, surgical correction of tricuspid regurgitation (TR) is associated with high rates of morbidity and mortality. Transvenous lead extraction (TLE) could potentially ameliorate CIED-induced TR; however, it carries inherent risks and frequently does not result in TR improvement. As multiple TTVI devices are in trial to gain regulatory approval, understanding which therapy is most appropriate among patients with a CIED is essential. This review centers on the nonsurgical treatment, including TLE and transcatheter tricuspid valve repair and replacement options, aimed at enhancing outcomes in patients with TR who also have concurrent CIEDs.
Asunto(s)
Cateterismo Cardíaco , Desfibriladores Implantables , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/fisiopatología , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Factores de Riesgo , Remoción de Dispositivos , Recuperación de la Función , Medición de RiesgoRESUMEN
BACKGROUND: Women have a higher prevalence of tricuspid regurgitation (TR) and present at more advanced stages as compared with men. Given the high operative mortality associated with tricuspid valve (TV) surgery, transcatheter tricuspid valve interventions (TTVI) have emerged as a promising treatment option. We explored sex-based differences among patients with significant TR who would be expected to be eligible for TTVI. METHODS: Between March 2021-2022, 12,677 unique adult patients underwent a transthoracic echocardiogram at our tertiary care institution. Clinical and echocardiographic data were collected for patients with more than moderate TR. The 2021 European Society of Cardiology valve guidelines were used to retrospectively define sub-populations who would have been eligible for TTVI, TV surgery, or medical therapy. Patients were grouped by sex and compared using t-tests, Wilcoxon rank-sum, Pearson chi-square, and Cox regression for survival analysis. RESULTS: Of 569 patients, 52% (296/569) were female. Men had a higher prevalence of left ventricular dysfunction (p < 0.001), mitral regurgitation (p = 0.023), and signs of heart failure (New York Heart Association stage III (p = 0.031)). Women had more isolated TR (p = 0.020) and TR due to severe pulmonary hypertension (p < 0.001). Most patients (74.6% of women, 76.9% of men) were precluded from both transcatheter and surgical intervention due to advanced disease. 10.8% of women and 9.2% of men would have qualified for TTVI (p = 0.511). CONCLUSION: The majority of patients with significant TR presenting to a tertiary care center are not eligible for TTVI. Sex is not a predictor of eligibility for TTVI among patients with significant TR.
Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Selección de Paciente , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Femenino , Masculino , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/mortalidad , Estudios Retrospectivos , Anciano , Factores Sexuales , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Factores de Riesgo , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Válvula Tricúspide/fisiopatología , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Persona de Mediana Edad , Anciano de 80 o más Años , Medición de Riesgo , Toma de Decisiones Clínicas , Prevalencia , Disparidades en el Estado de Salud , Factores de TiempoRESUMEN
Tricuspid regurgitation is a common valve disease with high incidence and poor prognosis. For elderly patients and those with a history of open heart surgery, second thoracotomy and valve replacement carry a high risk. Transcatheter tricuspid valve replacement (TTVR) has become an alternative treatment for patients with high surgical risk. LuX-Valve is a novel self-expandable valve that does not rely on radial force to anchor the valve annulus. The preliminary results have been satisfactory, and this technology is gradually being adopted in China and around the world. Successful implementation of this technique depends on echocardiographic preoperative screening, intraoperative guidance, and postoperative follow-up. The purpose of this article is to provide a state-of-the-art review of the key points and technical considerations for preoperative screening, intraoperative guidance, and postoperative follow-up for TTVR.
RESUMEN
BACKGROUND: Transcatheter tricuspid valve-in-valve (ViV) replacement has yielded good hemodynamic outcomes in the treatment of dysfunctional bioprosthetic valves (BPVs). Intentional fracture of certain rigid BPV frames, if feasible, allows a larger implanted valve when compared with implant into an unfractured BPV. There remains limited data on the feasibility of tricuspid valve frame fracture. AIMS: Evaluate the feasibility of transcatheter tricuspid ViV replatement with fracture of the underlying BPV ring. METHODS: An international multicenter registry of tricuspid ViV replacement with intentional tricuspid valve frame fracture was created. Demographic data along with procedural characteristics, outcomes, and follow-up data were collected. Comparison was made to the pre- and post-ViV replacement with fracture of the tricuspid valve frame conditions. RESULTS: Ten patients from six centers were included with a median age and weight of 29 years and 67.3 kg respectively. Tricuspid valve frame fracture was performed using a median balloon diameter 3 mm (IQR 3-5) larger than the true inner diameter (ID). The final ID was a mean of 1.5 mm (95% CI: 0.35, 2.64: p < 0.05), and median 1.1 mm (0.5, 2.1) larger than the reported true ID of the surgical BPV after ViV replacement. The mean tricuspid inflow gradient by echocardiogram decreased by 6.65 mmHg (95% CI: 4.14, 9.15: p < 0.001). All procedures were without complication, specifically there was no heart block, pericardial effusion, or right coronary disruption. CONCLUSION: Intentional tricuspid valve frame fracture with tricuspid ViV replacement is feasible and can increase the valve orifice potentially reducing the risk of ViV patient prosthesis mismatch and is not associated with significant complications.
RESUMEN
Despite progressively uncommon in Western countries, rheumatic heart disease still portrays a significant global burden. In elderly or high-surgical risk patients, plurivalvular disease may require a complex percutaneous approach. Transcatheter aortic valve implantation (TAVI) in patients with previous monoleaflet mitral prosthesis is challenging due to interference between the aortic valve and the rigid mitral mechanical prosthesis "ring." Prior cases report the use of CoreValve or Edwards Sapien aortic valves in patients with adequate mitro-aortic distance. Performing a second major procedure, such as tricuspid valve-in-valve (TVIV), sequentially during a single percutaneous intervention, increases treatment complexity. An 83-year-old woman with rheumatic heart disease, with previous implantation of a Bjork-Shiley monoleaflet mitral prosthesis, and Carpentier-Edwards 29 tricuspid bioprosthesis presented with decompensated heart failure due to severe aortic stenosis and tricuspid bioprosthesis stenosis. After HeartTeam discussion, the patient was deemed as inoperable due to a prohibitive surgical risk. As an alternative, a TAVI (Navitor FlexNav) and a transcatheter TVIV replacement (Edwards Sapiens 3 Ultra) were discussed and proposed, with both techniques being performed sequentially in a single procedure. TAVI in a patient with a previous monoleaflet mitral mechanical prosthesis and TVIV may be a feasible approach in inoperable patients with plurivalvular disease.
Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Mitral , Diseño de Prótesis , Cardiopatía Reumática , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Tricúspide , Humanos , Femenino , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Válvula Tricúspide/fisiopatología , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Cardiopatía Reumática/diagnóstico por imagen , Cardiopatía Reumática/fisiopatología , Cardiopatía Reumática/cirugía , Cardiopatía Reumática/terapia , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/instrumentación , Recuperación de la Función , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/diagnóstico por imagenRESUMEN
BACKGROUND: Functional tricuspid regurgitation (FTR) following left-sided valve surgery (LSVS) is of clinical significance due to its high recurrence and mortality rates. Transcatheter therapy presents a potential solution to address this issue. AIMS: The study aimed to assess the safety and efficacy of transcatheter tricuspid valve replacement using the Lux-Valve system in a single center for patients with FTR after LSVS. METHODS: From June 2020 to April 2023, 20 patients with symptomatic severe FTR after LSVS were referred to our center. A multidisciplinary cardiac team evaluated these patients for suitability for transcatheter tricuspid valve replacement with Lux-Valve systems. Primary efficacy and safety endpoints were immediate postoperative tricuspid regurgitation severity ≤ moderate and major adverse events during follow-up. RESULTS: Twenty patients (average age 65.7 ± 7.4 years; 65.0% women) successfully underwent Lux-Valve system implantation after LSVS. All patients achieved ≤ moderate tricuspid regurgitation immediately after the procedure. Only one patient (5.0%) experienced a procedure-related major adverse event, leading to in-hospital mortality due to pulmonary infection. At the 6-month follow-up, 17 patients (89.5%) improved to New York Heart Association functional class I to II (p < 0.001). The overall Kansas City Cardiomyopathy Questionnaire score significantly improved (35.9 ± 6.7 points to 58.9 ± 5.8 points, p < 0.001). CONCLUSION: The Lux-Valve system was found to be safe and effective for treating FTR after LSVS. It resulted in positive early outcomes, including a significant reduction in FTR, improved functional status, and enhanced quality of life, especially in high-risk patients.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Calidad de Vida , Resultado del Tratamiento , Cateterismo Cardíaco/métodosRESUMEN
INTRODUCTION: Prior investigations assessing the impact of race/ethnicity on outcomes after mitral valve (MV) surgery have reported conflicting findings. This analysis aimed to examine the association between race/ethnicity and operative presentation and outcomes of patients undergoing MV and tricuspid valve (TV) surgery. METHODS: We retrospectively analyzed 5984 patients (2730 female, median age 63 y) who underwent MV (n = 4,534, 76%), TV (n = 474, 8%) or both MV and TV (n = 976, 16%) surgery in a statewide collaborative from 2012 to 2021. The influence of race/ethnicity on preoperative characteristics, MV and TV repair rates, and postoperative outcomes was assessed for White (n = 4,244, 71%), Black (n = 1,271, 21%), Hispanic (n = 144, 2%), Asian (n = 171, 3%), and mixed/other race (n = 154, 3%) patients. RESULTS: Black patients, compared to White patients, had higher Society of Thoracic Surgeons predicted risk of morbidity/mortality (24.5% versus 13.1%; P < 0.001) and more comorbid conditions. Compared to White patients, Black and Hispanic patients were less likely to undergo an elective procedure (White 71%, Black 55%, Hispanic 58%; P < 0.001). Degenerative MV disease was more prevalent in White patients (White 62%, Black 41%, Hispanic 43%, Asian 51%, mixed/other 45%; P < 0.05), while rheumatic disease was more prevalent in non-White patients (Asian 28%, Hispanic 26%, mixed/other 25%, Black 17%, White 10%;P < 0.05). After multivariable adjustment, repair rates and adverse postoperative outcomes, including mortality, did not differ by racial/ethnic group. CONCLUSIONS: Patient race/ethnicity is associated with a higher burden of comorbidities at operative presentation and MV disease etiology. Strategies to improve early detection of valvular heart disease and timely referral for surgery may improve outcomes.
Asunto(s)
Válvula Mitral , Válvula Tricúspide , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Etnicidad , Disparidades en Atención de Salud/estadística & datos numéricos , Disparidades en Atención de Salud/etnología , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/etnología , Válvula Mitral/cirugía , Complicaciones Posoperatorias/etnología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Resultado del Tratamiento , Válvula Tricúspide/cirugía , Negro o Afroamericano , Asiático , Hispánicos o Latinos , BlancoRESUMEN
Both hyper- and hypothermia are problematic in temperature based forensic time since death estimation. Hyperthermia may occur in infection, traumatic brain injury, and intoxication. Hypothermia is encountered predominantly in exposure. Sepsis may present itself clinically as hypothermic. Sepsis is not uncommon in the forensic setting and mostly occurs in the context of malpractice accusations. There is usually little overlap between sepsis and typical forensic time since death estimation scenarios of violent or otherwise suspicious deaths. In the presented case, hypothermia and time since death estimations did collide. An inmate was found dead in his jail cell. Wardens claimed they had visually approached him alive relatively shortly prior. Rectal temperature measurements, using two separate crime scene thermometers as well as temperature loggers, revealed low rectal temperature at relatively high ambient temperature. These findings suggested a much longer postmortem interval and consequently raised doubts about the stated timeline. The wardens' claims were however confirmed by camera recordings, which also allowed a reasonable estimate of the true time of death. The cause of death was confirmed as septic organ failure at autopsy, which explained low rectal temperature. The presence of WISCHNEWSKI-spots was noted. When the PRISM-method was applied to the temperature recordings, low rectal temperature at the time of death was detected successfully. However, adaptation of the underlying equation for lower "starting temperature" did not produce satisfactory results. It is concluded that even though hypothermia at the time of death may possibly be detected from temperature data, attempts at time since death estimation for cases of hypothermia by adaptation of the equation should be avoided.
Asunto(s)
Temperatura Corporal , Hipotermia , Sepsis , Humanos , Masculino , Cambios Post Mortem , AdultoRESUMEN
AIMS: Transvenous lead extraction (TLE) is potentially complicated by significant tricuspid valve regurgitation increase (TRI). However, there are limited data on the effect of the bidirectional rotational mechanical sheaths on significant TRI. The aim of the present study was to investigate the rate of significant changes in tricuspid regurgitation (TR) severity following mechanical rotational TLE and their outcomes. METHODS AND RESULTS: In 158 patients (mean age 66 ± 16.9 years) undergoing mechanical rotational TLE, acute changes in TR severity were assessed by echocardiography evaluation. A significant acute TRI was defined as an increase of at least one grade with a post-extraction severity at least moderate. A total of 290 leads were extracted (mean implant duration, 93 ± 65 months). Significant TRI was noted in 5.7% of patients, and it was linked to tricuspid valve damage, TLE infection indication, and longer lead implant duration. Univariate predictors of significant TRI included implant duration of all leads [odds ratio (OR) 1.01; 95% confidence interval (CI) 1.003-1.018; P = 0.001] and right ventricular leads (OR 1.01; 95% CI 1.004-1.017; P = 0.002). Severe increase of TR following TLE was an independent predictor of mortality [hazard ratio (HR) 5.20; 95% CI 1.44-18.73; P = 0.012 ] along with severe systolic dysfunction (HR 2.37; 95% CI 1.01-5.20; P = 0.032), and systemic infection (HR 2.28; 95% CI 1.06-4.89; P = 0.035). CONCLUSION: Significant TRI was detected in 5.7% of patients following transvenous rotational mechanical lead extraction. The duration of lead implantation emerged as the sole predictor of significant TRI. Physicians engaged in TLE should exercise greater vigilance for this potential complication.
Asunto(s)
Desfibriladores Implantables , Remoción de Dispositivos , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/etiología , Masculino , Femenino , Remoción de Dispositivos/efectos adversos , Anciano , Persona de Mediana Edad , Desfibriladores Implantables/efectos adversos , Anciano de 80 o más Años , Índice de Severidad de la Enfermedad , Factores de Riesgo , Resultado del Tratamiento , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Válvula Tricúspide/fisiopatología , Factores de TiempoRESUMEN
BACKGROUND: Coxiella burnetii is a bacterium with extreme tenacity and contagiousness that is mainly transmitted by inhalation of contaminated aerosols. Nevertheless, a transmission by ticks is under discussion. We report a case of Q fever in an urban environment and far away from sheep breeding that caused a rare right-sided endocarditis. CASE PRESENTATION: A 55-year-old man who was in good health before the event developed a C. burnetii -endocarditis of the tricuspid valve. He had no contact with sheep and no recent travel in a rural or even endemic area. The infection originated in a strictly urban environment, and the patient's occupation as a cemetery gardener in Berlin, coupled with the close temporal and local exposure to wild boar, made a transmission by these animals a plausible hypothesis. The infection was confirmed by the German Reference Laboratory, and the patient recovered completely after treatment with doxycycline and hydrochlorquine. CONCLUSIONS: The specialities of this case report are the right-sided endocarditis and the transmission of C. burnetii in a metropolitan area without sheep contact. We think that this case should serve to increase awareness of the potential for Q fever infection even in non-rural areas.
Asunto(s)
Coxiella burnetii , Endocarditis Bacteriana , Fiebre Q , Válvula Tricúspide , Fiebre Q/transmisión , Fiebre Q/microbiología , Fiebre Q/diagnóstico , Fiebre Q/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Humanos , Válvula Tricúspide/microbiología , Endocarditis Bacteriana/microbiología , Endocarditis Bacteriana/transmisión , Endocarditis Bacteriana/tratamiento farmacológico , Coxiella burnetii/aislamiento & purificación , Animales , Antibacterianos/uso terapéutico , Doxiciclina/uso terapéutico , OvinosRESUMEN
BACKGROUND: Although chest trauma happens very often, accompanying tricuspid valve injuries occur rarely and may be manifested by scarce symptoms and signs. Pericardial rupture with cardiac herniation is even a bigger rarity. Transthoracic echocardiography plays a key role in the diagnosis of valve injuries but is of limited value in cardiac herniation. CASE PRESENTATION: We present the case of 58-year-old man who experienced severe chest trauma in a car accident. Symptoms of right heart failure occurred 10 years after the injury, due to the loss of tricuspid leaflet support caused by the rupture of tendinous chords with significant tricuspid regurgitation. Intraoperatively, old posttraumatic pericardial rupture into left pleura was also found, with partial cardiac herniation and pressure of the edge of pericardium on all left-sided coronary arteries simultaneously. The patient was successfully operated and is free of symptoms 4 years later. CONCLUSIONS: This case emphasizes the importance of timely diagnosis and underlines a mechanism that leads to delayed rupture of the tricuspid valve apparatus. Repeated echocardiography in all patients who experienced chest trauma could be of great importance. Also, given the limited value of echocardiography in posttraumatic pericardial rupture and cardiac herniation, cardiac computed tomography should be performed.