Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.978
Filtrar
Más filtros

Intervalo de año de publicación
1.
Proc Natl Acad Sci U S A ; 119(20): e2202812119, 2022 05 17.
Artículo en Inglés | MEDLINE | ID: mdl-35533282

RESUMEN

Developing facile approaches for preparing efficient electrocatalysts is of significance to promote sustainable energy technologies. Here, we report a facile iron-oxidizing bacteria corrosion approach to construct a composite electrocatalyst of nickel­iron oxyhydroxides combined with iron oxides. The obtained electrocatalyst shows improved electrocatalytic activity and stability for oxygen evolution, with an overpotential of ∼230 mV to afford the current density of 10 mA cm−2. The incorporation of iron oxides produced by iron-oxidizing bacteria corrosion optimizes the electronic structure of nickel­iron oxyhydroxide electrodes, which accounts for the decreased free energy of oxygenate generation and the improvement of OER activity. This work demonstrates a natural bacterial corrosion approach for the facile preparation of efficient electrodes for water oxidation, which may provide interesting insights in the multidisciplinary integration of innovative nanomaterials and emerging energy technologies.


Asunto(s)
Níquel , Oxígeno , Microbiología del Agua , Corrosión , Compuestos Férricos , Hierro , Agua
2.
Small ; 20(28): e2307742, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38326101

RESUMEN

Biodegradable medical implants promise to benefit patients by eliminating risks and discomfort associated with permanent implantation or surgical removal. The time until full resorption is largely determined by the implant's material composition, geometric design, and surface properties. Implants with a fixed residence time, however, cannot account for the needs of individual patients, thereby imposing limits on personalization. Here, an active Fe-based implant system is reported whose biodegradation is controlled remotely and in situ. This is achieved by incorporating a galvanic cell within the implant. An external and wireless signal is used to activate the on-board electronic circuit that controls the corrosion current between the implant body and an integrated counter electrode. This configuration leads to the accelerated degradation of the implant and allows to harvest electrochemical energy that is naturally released by corrosion. In this study, the electrochemical properties of the Fe-30Mn-1C/Pt galvanic cell model system is first investigated and high-resolution X-ray microcomputed tomography is used to evaluate the galvanic degradation of stent structures. Subsequently, a centimeter-sized active implant prototype is assembled with conventional electronic components and the remotely controlled corrosion is tested in vitro. Furthermore, strategies toward the miniaturization and full biodegradability of this system are presented.


Asunto(s)
Metales , Corrosión , Metales/química , Microtomografía por Rayos X , Prótesis e Implantes , Electroquímica , Implantes Absorbibles , Técnicas Electroquímicas/métodos
3.
Chem Res Toxicol ; 37(2): 361-373, 2024 02 19.
Artículo en Inglés | MEDLINE | ID: mdl-38294881

RESUMEN

Skin Corrosion/Irritation (Corr./Irrit.) has long been a health hazard in the Globally Harmonized System (GHS). Several in silico models have been built to predict Skin Corr./Irrit. as an alternative to the increasingly restricted animal testing. However, current studies are limited by data amount/quality and model availability. To address these issues, we compiled a traceable consensus GHS data set comprising 731 Corr., 1283 Irrit., and 1205 negative (Neg.) samples from 6 governmental databases and 2 external data sets. Then, a series of binary classifiers were developed with five machine learning (ML) algorithms and six molecular representations. For 10-fold cross-validation, the best Corr. vs Neg. classifier achieved an Area Under the Receiver Operating Characteristic Curve (AUC) of 97.1%, while the best Irrit. vs Neg. classifier achieved an AUC of 84.7%. Compared with existing in silico tools on external validation, our Attentive FP classifiers showed the highest metrics on Corr. vs Neg. and the second highest accuracy on Irrit. vs Neg. The SHapley Additive exPlanation approach was further applied to figure out important molecular features, and the attention weights were visualized to perform interpretable prediction. Structural alerts associated with Skin Corr./Irrit. were also identified. The interpretable Attentive FP classifiers were integrated into the software AttentiveSkin at https://github.com/BeeBeeWong/AttentiveSkin. The conventional ML classifiers are also provided on our platform admetSAR at http://lmmd.ecust.edu.cn/admetsar2/. Considering the data deficiency and the limited model availability of Skin Corr./Irrit., we believe that our data set and models could facilitate chemical safety assessment and relevant studies.


Asunto(s)
Algoritmos , Piel , Animales , Corrosión , Programas Informáticos , Aprendizaje Automático
4.
Arch Microbiol ; 206(7): 295, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38856934

RESUMEN

Microbial community biofilm exists in the household drinking water system and would pose threat to water quality. This paper explored biofilm formation and chlorination resistance of ten dual-species biofilms in three typical household pipes (stainless steel (SS), polypropylene random (PPR), and copper), and investigated the role of interspecific interaction. Biofilm biomass was lowest in copper pipes and highest in PPR pipes. A synergistic or neutralistic relationship between bacteria was evident in most biofilms formed in SS pipes, whereas four groups displayed a competitive relationship in biofilms formed in copper pipe. Chlorine resistance of biofilms was better in SS pipes and worse in copper pipes. It may be helped by interspecific relationships, but was more dependent on bacteria and resistance mechanisms such as more stable extracellular polymeric substance. The corrosion sites may also protect bacteria from chlorination. The findings provide useful insights for microbial control strategies in household drinking water systems.


Asunto(s)
Bacterias , Biopelículas , Cloro , Agua Potable , Biopelículas/efectos de los fármacos , Biopelículas/crecimiento & desarrollo , Cloro/farmacología , Bacterias/efectos de los fármacos , Bacterias/genética , Bacterias/aislamiento & purificación , Bacterias/clasificación , Agua Potable/microbiología , Cobre/farmacología , Microbiología del Agua , Acero Inoxidable , Polipropilenos , Abastecimiento de Agua , Halogenación , Corrosión , Desinfectantes/farmacología
5.
Langmuir ; 40(11): 5738-5752, 2024 03 19.
Artículo en Inglés | MEDLINE | ID: mdl-38450610

RESUMEN

The pumpkin leaf was extracted by the decoction method, and it was used as an eco-friendly, nontoxic inhibitor of copper in 0.5 M H2SO4 corrosion media. To evaluate the composition and protective capacity of the pumpkin leaf extract, Fourier infrared spectroscopy, electrochemical testing, XPS, AFM, and SEM were employed. The results showed that the pumpkin leaf extract (PLE) is an effective cathode corrosion inhibitor, exhibiting exceptional protection for copper within a specific temperature range. The corrosion inhibition efficiency of the PLE against copper reached 89.98% when the concentration of the PLE reached 800 mg/L. Furthermore, when the temperature and soaking time increased, the corrosion protection efficiency of 800 mg/L PLE on copper consistently remained above 85%. Analysis of the morphology also indicated that the PLE possesses equally effective protection for copper at different temperatures. Furthermore, XPS analysis reveals that the PLE molecules are indeed adsorbed to form an adsorption film, which is consistent with Langmuir monolayer adsorption. Molecular dynamics simulations and quantum chemical calculations were conducted on the main components of the PLE.


Asunto(s)
Cucurbita , Corrosión , Cobre/química , Acero/química , Extractos Vegetales/química
6.
Chem Rev ; 122(12): 11131-11168, 2022 06 22.
Artículo en Inglés | MEDLINE | ID: mdl-35687869

RESUMEN

Interpretation of impedance spectroscopy data requires both a description of the chemistry and physics that govern the system and an assessment of the error structure of the measurement. The approach presented here includes use of graphical methods to guide model development, use of a measurement model analysis to assess the presence of stochastic and bias errors, and a systematic development of interpretation models in terms of the proposed reaction mechanism and physical description. Application to corrosion, batteries, and biological systems is discussed, and emerging trends in interpretation and implementation of impedance spectroscopy are presented.


Asunto(s)
Espectroscopía Dieléctrica , Suministros de Energía Eléctrica , Corrosión , Espectroscopía Dieléctrica/métodos , Impedancia Eléctrica
7.
Environ Sci Technol ; 58(1): 522-533, 2024 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-38052449

RESUMEN

Microbially induced corrosion (MIC) on concrete represents a serious issue impairing the lifespan of coastal/marine infrastructure. However, currently developed concrete corrosion protection strategies have limitations in wide applications. Here, a biomineralization method was proposed to form a biomineralized film on concrete surfaces for corrosion inhibition. Laboratory seawater corrosion experiments were conducted under different conditions [e.g., chemical corrosion (CC), MIC, and biomineralization for corrosion inhibition]. A combination of chemical and mechanical property measurements of concrete (e.g., sulfate concentrations, permeability, mass, and strength) and a genotypic-based investigation of formed concrete biofilms was conducted to evaluate the effectiveness of the biomineralization approach on corrosion inhibition. The results show that MIC resulted in much higher corrosion rates than CC. However, the biomineralization treatment effectively inhibited corrosion because the biomineralized film decreased the total and relative abundance of sulfate-reducing bacteria (SRB) and acted as a protective layer to control the diffusion of sulfate and isolate the concrete from the corrosive SRB communities, which helps extend the lifespan of concrete structures. Moreover, this technique had no negative impact on the native marine microbial communities. Our study contributes to the potential application of biomineralization for corrosion inhibition to achieve long-term sustainability for major marine concrete structures.


Asunto(s)
Bacterias , Biomineralización , Corrosión , Biopelículas , Sulfatos
8.
Environ Sci Technol ; 58(12): 5606-5615, 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38470122

RESUMEN

Gaps in the United States Environmental Protection Agency (US EPA) Lead and Copper Rule (LCR) leave some consumers and their pets vulnerable to high cuprosolvency in drinking water. This study seeks to help proactive utilities who wish to mitigate cuprosolvency problems through the addition of orthophosphate corrosion inhibitors. The minimum doses of orthophosphate necessary to achieve acceptable cuprosolvency in relatively new copper pipe were estimated as a function of alkalinity via linear regressions for the 90th, 95th, and 100th percentile copper tube segments (R2 > 0.98, n = 4). Orthophosphate was very effective at reducing cuprosolvency in the short term but, in some cases, resulted in higher long-term copper concentrations than the corresponding condition without orthophosphate. Alternatives to predicting "long-term" results for copper tubes using simpler bench tests starting with fresh Cu(OH)2 solids showed promise but would require further vetting to overcome limitations such as maintaining water chemistry and orthophosphate residuals and to ensure comparability to results using copper tube.


Asunto(s)
Agua Potable , Contaminantes Químicos del Agua , Estados Unidos , Cobre/análisis , Fosfatos , Abastecimiento de Agua , Corrosión
9.
Environ Sci Technol ; 58(4): 2038-2047, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38241248

RESUMEN

Single-particle inductively coupled plasma mass spectrometry (spICP-MS) has been used to characterize metallic nanoparticles (NPs) assuming that all NPs are spherical and composed of pure element. However, environmental NPs generally do not meet these criteria, suggesting that spICP-MS may underestimate their true sizes. This study employed a system hyphenating the atomizer (ATM), differential mobility analyzer (DMA), and spICP-MS to characterize metallic NPs in tap water. Its performance was validated by using reference Au nanoparticles (AuNPs) and Ag-shelled AuNPs. The hyphenated system can determine the actual size and metal composition of both NPs with additional heating after ATM, while stand-alone spICP-MS misidentified the Ag-shelled AuNPs as smaller individual AgNPs and AuNPs. Dissolved metal ions could introduce artifact NPs after heating but could be eliminated by centrifugation. The hyphenated system was applied to characterize Fe-containing and Pb-containing NPs resulting from the corrosion of plumbing materials in tap water. The mode sizes of Fe-containing and Pb-containing NPs were determined to be 110 and 100 nm and the particle number concentrations were determined to be 4.99 × 107 and 1.40 × 106 #/mL, respectively. Cautions should be paid to potential changes in particle size induced by heating for metallic NPs with a low melting point or a high organic content.


Asunto(s)
Nanopartículas del Metal , Nanopartículas del Metal/química , Oro/química , Plomo , Ingeniería Sanitaria , Corrosión , Nebulizadores y Vaporizadores , Tamaño de la Partícula , Agua
10.
Macromol Rapid Commun ; 45(19): e2400354, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38987906

RESUMEN

In this work, graphene oxide (GO) and epoxy-functionalized graphene oxide (GOSi) are chosen as additives and incorporated into epoxy resin (EP) for nanocomposite photo-coating films (GO/EP and GOSi/EP series). Compared to GO/EP, the GOSi/EP nanocomposite demonstrates strong binding and excellent dispersibility, highlighting covalent bonding between GOSi and the epoxy coating. Furthermore, GOSi/EP-based films demonstrated superior thermal stability and adhesion performance on galvanized steel plates. The corrosion performance of the coated galvanized steel is investigated using electrochemical impedance spectroscopy (EIS) and polarization curve analysis (Tafel). The effectiveness of corrosion protection is evaluated based on a combination of photoreactivity, crosslinking density, dispersity, and adhesion properties. Out of all the treated films, the film based on 0.1GOSi/EP exhibited the highest percentage of inhibition (98.89%) and demonstrated superior long-term anticorrosion stability. In addition, the 0.1GOSi/EP based formulation showed remarkable antibacterial activity against S. aureus, resulting in a 92% reduction. This work demonstrates the development of a facile, environmentally friendly functionalized graphene oxide/epoxy photocured film with superior dual functionalities in both anticorrosion and antibacterial properties. These advancements hold promising potential for impactful practical applications.


Asunto(s)
Antibacterianos , Resinas Epoxi , Grafito , Staphylococcus aureus , Grafito/química , Grafito/farmacología , Antibacterianos/química , Antibacterianos/farmacología , Resinas Epoxi/química , Staphylococcus aureus/efectos de los fármacos , Corrosión , Pruebas de Sensibilidad Microbiana , Propiedades de Superficie , Procesos Fotoquímicos , Nanocompuestos/química
11.
Biometals ; 37(2): 337-355, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37904075

RESUMEN

Fe was selected as an alloying element for the first time to prepare a new antibacterial titanium alloy based on micro-area potential difference (MAPD) antibacterial mechanism. The microstructure, the corrosion resistance, the mechanical properties, the antibacterial properties and the cell biocompatibility have been investigated in detail by optical microscopy, scanning electron microscopy, electrochemical testing, mechanical property test, plate count method and cell toxicity measurement. It was demonstrated that heat treatment had a significant on the compressive mechanical properties and the antibacterial properties. Ti-xFe (x = 3,5 and 9) alloys after 850 °C/3 h + 550 °C/62 h heat treatment exhibited strong antimicrobial properties with an antibacterial rate of more than 90% due to the MAPD caused by the redistribution of Fe element during the aging process. In addition, the Fe content and the heat treatment process had a significant influence on the mechanical properties of Ti-xFe alloy but had nearly no effect on the corrosion resistance. All Ti-xFe alloys showed non-toxicity to the MC3T3 cell line in comparison with cp-Ti, indicating that the microzone potential difference had no adverse effect on the corrosion resistance, cell proliferation, adhesion, and spreading. Strong antibacterial properties, good cell compatibility and good corrosion resistance demonstrated that Ti-xFe alloy might be a candidate titanium alloy for medical applications.


Asunto(s)
Aleaciones , Titanio , Titanio/farmacología , Titanio/química , Aleaciones/farmacología , Aleaciones/química , Staphylococcus aureus , Antibacterianos/farmacología , Antibacterianos/química , Hierro/farmacología , Corrosión , Ensayo de Materiales
12.
Biomed Eng Online ; 23(1): 72, 2024 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-39054528

RESUMEN

Nanotechnology has contributed important innovations to medicine and dentistry, and has also offered various applications to the field of orthodontics. Intraoral appliances must function in a complex environment that includes digestive enzymes, a diverse microbiome, mechanical stress, and fluctuations of pH and temperature. Nanotechnology can improve the performance of orthodontic brackets and archwires by reducing friction, inhibiting bacterial growth and biofilm formation, optimizing tooth remineralization, improving corrosion resistance and biocompatibility of metal substrates, and accelerating or decelerating orthodontic tooth movement through the application of novel nanocoatings, nanoelectromechanical systems, and nanorobots. This comprehensive review systematically explores the orthodontic applications of nanotechnology, particularly its impacts on tooth movement, antibacterial activity, friction reduction, and corrosion resistance. A search across PubMed, the Web of Science Core Collection, and Google Scholar yielded 261 papers, of which 28 met our inclusion criteria. These selected studies highlight the significant benefits of nanotechnology in orthodontic devices. Recent clinical trials demonstrate that advancements brought by nanotechnology may facilitate the future delivery of more effective and comfortable orthodontic care.


Asunto(s)
Antibacterianos , Fricción , Nanotecnología , Ortodoncia , Técnicas de Movimiento Dental , Humanos , Técnicas de Movimiento Dental/instrumentación , Corrosión , Antibacterianos/farmacología , Antibacterianos/química
13.
Environ Res ; 242: 117640, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38007078

RESUMEN

Industries today place a high premium on environmentally friendly supplies that may effectively inhibit metal dissolution at a reasonable cost. Hence, in this paper, we assessed the corrosion inhibition effectiveness of the Thiazole derivative namely, 2, 2-Dithio Bisbenzothiazole (DBBT) against mild steel (MS) corrosion in 1 M HCl. Several experimental approaches, including gravimetric analysis, potentiodynamic polarization (PDP), electrochemical impedance spectroscopy (EIS), and surface exploration using scanning electron/atomic force microscopy (SEM/AFM) and contact angle (CA), were utilized to conduct the measurements. In 1 M HCl corrosive medium at 298 K in the subsistence of 800 ppm of DBBT, this experiment indicated DBBT as an environment-friendly and sustainable corrosion inhibitor (CI) for MS, demonstrating an inhibition efficiency (IE %) of 97.71%. To deliver a deeper knowledge of the mechanism behind inhibitive behavior, the calculated thermodynamic and activation characteristics were applied. The calculated Gibbs free energy values indicated that the CI interacted physically and chemically with the MS surface, validating physio-chemical adsorption. The findings of the EIS research revealed that an upsurge in the doses of the CI is escorted by an upsurge in polarization resistance (Rp) from (88.05 → 504.04) Ωcm2, and a diminution in double layer capacitance (Cdl) from (97.46 → 46.33) µFcm-2 at (50 → 800) ppm respectively, affirming the inhibitive potential of DBBT. Additionally, the greatest displacement in Ecorr value being 76.13 mV < 85 mV, indicating that DBBT act as a mixed-form CI. To study the further impacts of DBBT on the inhibition capabilities of the compound under investigation, density functional theory (DFT) and molecular dynamics (MD) simulation were employed. Chemical and electrochemical approaches are in agreement with the computational analysis indicating DBBT is the most efficient CI.


Asunto(s)
Electrones , Acero , Corrosión , Adsorción , Concentración de Iones de Hidrógeno
14.
Environ Res ; 261: 119765, 2024 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-39134113

RESUMEN

Anaerobic microbiologically influenced corrosion (MIC) of Fe (0) metals causes great harm to the environment and economy, which depends on the key electron transfer process between anaerobic microorganisms and Fe (0) metals. However, the key electron transfer process in microbiota dominating MIC remains unclear, especially for methanogenic microbiota wildly distributed in the environment. Herein, three different methanogenic microbiota (Methanothrix, Methanospirillum, and Methanobacterium) were acclimated to systematically investigate electron transfer pathways on corroding Q235A steel coupons. Results indicated that microbiota dominated by Methanothrix, Methanospirillum, or Methanobacterium accelerated the steel corrosion mainly through direct electron transfer (DET) pathway, H2 mediated electron transfer (HMET) pathway, and combined DET and HMET pathways, respectively. Compared with Methanospirillum dominant microbiota, Methanothrix or Methanobacterium dominant microbiota caused more methane production, higher weight loss, corrosion pits with larger areas, higher corrosion depth, and smaller corrosion pits density. Such results reflected that the DET process between microbiota and Fe (0) metals decided the biocorrosion degree and behavior of Fe (0) metals. This study insightfully elucidates the mechanisms of methanogenic microbiota on corroding steels, in turn providing new insights for anti-corrosion motives.


Asunto(s)
Hierro , Metano , Microbiota , Acero , Corrosión , Metano/metabolismo , Hierro/metabolismo , Transporte de Electrón
15.
Environ Res ; 252(Pt 2): 118833, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38599446

RESUMEN

Thiocyanate (SCN-), a non-volatile inorganic pollutant, is commonly found in various types of industrial wastewater, which is resistant to hydrolysis and has the potential to be toxic to organisms. Premagnetized iron-copper-carbon ternary micro-electrolytic filler (pre-Fe/Cu/C) was prepared to degrade SCN-. Pre-Fe/Cu/C exhibited the most significant enhancement effect on SCN- removal when magnetized for 5 min with an intensity of 100 mT, and the SCN- removal rate was the highest at an initial pH of 3.0 and an aeration rate of 1.6 L/min. The electrochemical corrosion and electron transfer in the pre-Fe/Cu/C system were confirmed through SEM, XPS, FTIR, XRD, and electrochemical tests. This resulted in the formation of more corrosion products and multiple cycles of Fe2+/Fe3+ and Cu0/Cu+/Cu2+. Additionally, density functional theory (DFT) calculations and electron paramagnetic resonance (EPR) were utilized to illustrate the oxygen adsorption properties of the materials and the participation of reactive oxygen species (1O2, ·O2-, and ·OH) in SCN- removal. The degradation products of SCN- were identified as SO42-, HCO3-, NH4+, and N2. This study introduced the use of permanent magnets for the first time to enhance Fe/Cu/C ternary micro-electrolytic fillers, offering a cost-effective, versatile, and stable approach that effectively effectively enhanced the degradation of SCN-.


Asunto(s)
Cobre , Hierro , Tiocianatos , Contaminantes Químicos del Agua , Tiocianatos/química , Cobre/química , Hierro/química , Contaminantes Químicos del Agua/química , Contaminantes Químicos del Agua/análisis , Carbono/química , Corrosión
16.
Appl Microbiol Biotechnol ; 108(1): 253, 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38441693

RESUMEN

The synergistic corrosion effect of acid-producing bacteria (APB) and magnetite on carbon steel corrosion was assessed using two different microbial consortia. A synergistic corrosion effect was observed exclusively with Consortium 2, which was composed of Enterobacter sp., Pseudomonas sp., and Tepidibacillus sp. When Consortium 2 was accompanied by magnetite, uniform corrosion and pitting rates were one-time higher (0.094 mm/year and 0.777 mm/year, respectively) than the sum of the individual corrosion rates promoted by the consortium and deposit separately (0.084 and 0.648 mm/year, respectively). The synergistic corrosion effect observed exclusively with Consortium 2 is attributed to its microbial community structure. Consortium 2 exhibited higher microbial diversity that benefited the metabolic status of the community. Although both consortia induced acidification of the test solution and metal surface through glucose fermentation, heightened activity levels of Consortium 2, along with increased surface roughness caused by magnetite, contributed to the distinct synergistic corrosion effect observed with Consortium 2 and magnetite. KEY POINTS: • APB and magnetite have a synergistic corrosion effect on carbon steel. • The microbial composition of APB consortia drives the synergistic corrosion effect. • Magnetite increases carbon steel surface roughness.


Asunto(s)
Óxido Ferrosoférrico , Microbiota , Corrosión , Carbono , Acero
17.
Biofouling ; 40(2): 193-208, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38456659

RESUMEN

Updated understanding on the effect of biofouling on corrosion rate is needed to protect marine structures as climate change is altering seawater physiochemistry and biofouling organism distribution. Multi-disciplinary techniques can improve understanding of biofouling development and associated corrosion rates on metals immersed in natural seawater (NSW). In this study, the development of biofouling and corrosion on welded Nickel Aluminium Bronze (NAB) was investigated through long-term immersion tests in NSW, simulated seawater (SSW) and air. Biofouling was affected by geographic location within the marina and influenced corrosion extent. The corrosion rate of NAB was accelerated in the initial months of exposure in NSW (1.27 mm.yr-1) and then settled to 0.11 mm.yr-1 (annual average). This was significantly higher than the 0.06 mm.yr-1 corrosion rate measured in SSW, which matched published rates. The results suggest that corrosion rates for cast NAB should be revised to take account of biofouling and updated seawater physiochemistry.


Asunto(s)
Incrustaciones Biológicas , Biopelículas , Aluminio/química , Níquel , Corrosión , Agua de Mar/química
18.
Biofouling ; 40(9): 617-631, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39291398

RESUMEN

The impact of Flavin adenine dinucleotide (FAD) on sulfate-reducing bacteria (SRB) corrosion of a pipeline welded joint (WJ) was investigated under anaerobic condition in this paper. The results showed that the thickness of the corrosion product on heat affected zone (HAZ) was lower than that on base metal (BM) and welded zone (WZ), and the FAD addition enhanced the development of the protruding microbial tubercles on the WJ. The local corrosion degrees of the BM and WZ coupons were significantly higher than that of the HAZ coupon. Besides, the FAD addition simultaneously promoted local corrosion of all three zones of the WJ in the SRB inoculated environment, and the promotion role was much more pronounced on the WZ coupons. The selective promotion effect of FAD on SRB corrosion in the WJ was attributed to the special structure of the WZ, the selected SRB attachment and the FAD/FADH2 redox feedback cycle.


Asunto(s)
Desulfovibrio desulfuricans , Flavina-Adenina Dinucleótido , Corrosión , Flavina-Adenina Dinucleótido/metabolismo , Flavina-Adenina Dinucleótido/química , Desulfovibrio desulfuricans/metabolismo , Oxidación-Reducción , Biopelículas
19.
Biofouling ; 40(5-6): 333-347, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38836545

RESUMEN

The corrosion behaviors of four pure metals (Fe, Ni, Mo and Cr) in the presence of sulfate reducing bacteria (SRB) were investigated in enriched artificial seawater (EASW) after 14-day incubation. Metal Fe and metal Ni experienced weight losses of 1.96 mg cm-2 and 1.26 mg cm-2, respectively. In contrast, metal Mo and metal Cr exhibited minimal weight losses, with values of only 0.05 mg cm-2 and 0.03 mg cm-2, respectively. In comparison to Mo (2.2 × 106 cells cm-2) or Cr (1.4 × 106 cells cm-2) surface, the sessile cell counts on Fe (4.0 × 107 cells cm-2) or Ni (3.1 × 107 cells cm-2) surface was higher.


Asunto(s)
Adhesión Bacteriana , Sulfatos , Corrosión , Sulfatos/química , Metales/química , Agua de Mar/microbiología , Agua de Mar/química , Biopelículas/efectos de los fármacos , Biopelículas/crecimiento & desarrollo , Bacterias/efectos de los fármacos , Incrustaciones Biológicas/prevención & control
20.
J Oral Maxillofac Surg ; 82(1): 56-64, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37898154

RESUMEN

BACKGROUND: Corrosion products resulting from the degradation of the dental implant surface due to biological fluids and infection may accumulate in the body and lead to clinical consequences. PURPOSE: The primary aim of this study is to measure the accumulation of dental implant corrosion products in the human body and the secondary aim is to estimate the association between corrosion products and fatigue. STUDY DESIGN, SETTING, SAMPLE: This study was designed as a prospective cross-sectional and was conducted with patients presenting at to the Department of Oral and Maxillofacial Surgery. The study included patients with Grade IV dental implants made of pure titanium (Ti) at the bone level and Grade V abutments composed of Ti, aluminum (Al), and vanadium (V). Individuals possessing different metallic implants and those prone to metal exposure were not included in the study. Blood and hair samples were procured from each participant and subsequently analyzed. PREDICTOR VARIABLES: The predictor variable is implant exposure, and it was divided into 3 groups; Group I, patients with healthy dental implants; Group II, patients with peri-implantitis; Control Group, individuals without dental implants. MAIN OUTCOME VARIABLES: The primary outcome variables are Al, Ti, V levels in blood and hair samples and the secondary outcome variable is the fatigue questionnaire score. COVARIATES: Age and gender, along with the dental implant number and duration of exposure within the study groups, are utilized as covariates. ANALYSES: Groups were compared using the Kruskal-Wallis and Mann-Whitney U-tests. Spearman's correlation coefficient determined relationships between groups, signifying significance with P values <.05. RESULTS: The sample consisted of 30 patients aged 18 to 68, with 53% being female and 47% male. The differences among the 3 groups in the median values of blood Ti, V; hair Al, Ti, V; and fatigue questionnaire scores were not statistically significant (P > .05). However, the median blood Al value was statistically higher in Group II (P < .05). CONCLUSIONS AND RELEVANCE: While the presence of healthy dental implants may not affect the accumulation of Al, Ti, and V within the body, patients with peri-implantitis exhibited elevated blood Al levels, possibly due to infection influencing the corrosion process.


Asunto(s)
Implantes Dentales , Periimplantitis , Humanos , Masculino , Femenino , Corrosión , Estudios Transversales , Cuerpo Humano , Estudios Prospectivos , Titanio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA