Your browser doesn't support javascript.
loading
An electronic pressure-meter nociception paw test for rats.
Vivancos, G G; Verri, W A; Cunha, T M; Schivo, I R S; Parada, C A; Cunha, F Q; Ferreira, S H.
Afiliación
  • Vivancos GG; Departamento de Farmacologia, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brasil.
Braz J Med Biol Res ; 37(3): 391-9, 2004 Mar.
Article en En | MEDLINE | ID: mdl-15060709
The objective of the present investigation was to compare the sensitivity of an electronic nociceptive mechanical paw test with classical mechanical tests to quantify the intensity variation of inflammatory nociception. The electronic pressure-meter test consists of inducing the hindpaw flexion reflex by poking the plantar region with a polypropylene pipette tip adapted to a hand-held force transducer. This method was compared with the classical von Frey filaments test and with the rat paw constant pressure test, a modification of the Randall and Selitto test developed by our group. When comparing the three methods, the electronic pressure-meter and the rat paw constant pressure test, but not the von Frey filaments test, detected time vs treatment interactions in prostaglandin E2 (PGE2)-induced hypernociception. Both methods also detected the PGE2-induced hypernociception in dose- (50-400 ng/paw) and time- (1-4 h) dependent manners, and time vs treatment interactions induced by carrageenin (25-400 microg/paw). Furthermore, the electronic pressure-meter test was more sensitive at early times, whereas the constant pressure test was more sensitive at later times. Moreover, the electronic pressure-meter test detected the dose-dependent antinociceptive effect of local indomethacin (30-300 microg/paw) and dipyrone (80-320 microg/paw) on carrageenin- (200 microg/paw) and PGE2- (100 ng/paw) induced hypernociception, respectively, and also detected the ineffectiveness of indomethacin (300 microg) on the effect of PGE2. Our results show that the electronic pressure-meter provides a sensitive, objective and quantitative mechanical nociceptive test that could be useful to characterize new nociceptive inflammatory mediators and also to evaluate new peripheral analgesic substances.
Asunto(s)
Buscar en Google
Banco de datos: MEDLINE Asunto principal: Dimensión del Dolor / Antiinflamatorios no Esteroideos Tipo de estudio: Diagnostic_studies Límite: Animals Idioma: En Revista: Braz J Med Biol Res Año: 2004 Tipo del documento: Article País de afiliación: Brasil
Buscar en Google
Banco de datos: MEDLINE Asunto principal: Dimensión del Dolor / Antiinflamatorios no Esteroideos Tipo de estudio: Diagnostic_studies Límite: Animals Idioma: En Revista: Braz J Med Biol Res Año: 2004 Tipo del documento: Article País de afiliación: Brasil