Performance of the improved version of monte Carlo code A3MCNP for large-scale shielding problems.
Omura, M; Miyake, Y; Hasegawa, T; Ueki, K; Sato, O; Haghighat, A; Sjoden, G E.
Afiliación
  • Omura M; Mitsubishi Heavy Industries, Yokohama 220-8401, Japan. masaki_omura@mhi.co.jp
Radiat Prot Dosimetry ; 116(1-4 Pt 2): 493-7, 2005.
Article en En | MEDLINE | ID: mdl-16604685
ABSTRACT
A3MCNP (Automatic Adjoint Accelerated MCNP) is a revised version of the MCNP Monte Carlo code, which automatically prepares variance reduction parameters for the CADIS (Consistent Adjoint Driven Importance Sampling) methodology. Using a deterministic 'importance' (or adjoint) function, CADIS performs source and transport biasing within the weight-window technique. The current version of A3MCNP uses the three-dimensional (3-D) Sn transport TORT code to determine a 3-D importance function distribution. Based on simulation of several real-life problems, it is demonstrated that A3MCNP provides precise calculation results with a remarkably short computation time by using the proper and objective variance reduction parameters. However, since the first version of A3MCNP provided only a point source configuration option for large-scale shielding problems, such as spent-fuel transport casks, a large amount of memory may be necessary to store enough points to properly represent the source. Hence, we have developed an improved version of A3MCNP (referred to as A3MCNPV) which has a volumetric source configuration option. This paper describes the successful use of A3MCNPV for a concrete cask neutron and gamma-ray shielding problem, and a PWR dosimetry problem.
Asunto(s)
Buscar en Google
Banco de datos: MEDLINE Asunto principal: Protección Radiológica / Radiometría / Algoritmos / Programas Informáticos / Método de Montecarlo / Modelos Estadísticos / Materiales de Construcción Tipo de estudio: Evaluation_studies / Health_economic_evaluation / Risk_factors_studies Idioma: En Revista: Radiat Prot Dosimetry Año: 2005 Tipo del documento: Article País de afiliación: Japón
Buscar en Google
Banco de datos: MEDLINE Asunto principal: Protección Radiológica / Radiometría / Algoritmos / Programas Informáticos / Método de Montecarlo / Modelos Estadísticos / Materiales de Construcción Tipo de estudio: Evaluation_studies / Health_economic_evaluation / Risk_factors_studies Idioma: En Revista: Radiat Prot Dosimetry Año: 2005 Tipo del documento: Article País de afiliación: Japón