Your browser doesn't support javascript.
loading
Impact of scar on water-perfusable tissue index in chronic ischemic heart disease: Evaluation with PET and contrast-enhanced MRI.
Knaapen, Paul; Bondarenko, Olga; Beek, Aernout M; Götte, Marco J W; Boellaard, Ronald; van der Weerdt, Arno P; Visser, Cees A; van Rossum, Albert C; Lammertsma, Adriaan A; Visser, Frans C.
Afiliación
  • Knaapen P; Department of Cardiology, 6D 120, VU University Medical Center, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands. p.knaapen@vumc.nl
Mol Imaging Biol ; 8(4): 245-51, 2006.
Article en En | MEDLINE | ID: mdl-16791751
BACKGROUND: The water-perfusable tissue index (PTI) is assumed to differentiate viable myocardium from scar tissue, but histological comparisons in humans are lacking. The present study compares PTI with delayed contrast-enhanced magnetic resonance imaging (DCE-MRI), a validated marker of fibrotic tissue, in patients with ischemic left ventricular (LV) dysfunction. In addition, the optimal PTI threshold for detection of myocardial viability was defined when DCE-MRI was taken as a reference. MATERIALS: Twenty patients with ischemic LV dysfunction were studied with positron emission tomography, using oxygen-15-labeled water and carbon monoxide as tracers, and DCE-MRI. RESULTS: Of the 200 analyzed segments, 112 demonstrated DCE and were subsequently divided in three subgroups according to the severity of enhancement. PTI was 1.04 +/- 0.21 in control segments and gradually decreased with increasing extent of DCE to 0.77 +/- 0.31 for segments with transmural enhancement (p < 0.001). However, PTI progressively underestimated infarct size with increasing quantities of scar tissue (r = 0.61, p < 0.01). A PTI cutoff value of 0.89 yielded the best diagnostic accuracy for detection of myocardial viability with sensitivity and specificity values of 75 and 77%, respectively. CONCLUSIONS: PTI is inversely related to the extent of scar tissue estimated by DCE-MRI in patients with chronic ischemic heart disease and LV dysfunction. However, with increasing quantities of scar tissue, PTI overestimates the extent of residual viable tissue. A PTI threshold of 0.89 yields the best diagnostic accuracy for viability detection.
Asunto(s)
Buscar en Google
Banco de datos: MEDLINE Asunto principal: Agua / Reperfusión Miocárdica / Cicatriz / Isquemia Miocárdica / Angiografía por Resonancia Magnética / Tomografía de Emisión de Positrones Tipo de estudio: Evaluation_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Mol Imaging Biol Asunto de la revista: BIOLOGIA MOLECULAR / DIAGNOSTICO POR IMAGEM Año: 2006 Tipo del documento: Article País de afiliación: Países Bajos
Buscar en Google
Banco de datos: MEDLINE Asunto principal: Agua / Reperfusión Miocárdica / Cicatriz / Isquemia Miocárdica / Angiografía por Resonancia Magnética / Tomografía de Emisión de Positrones Tipo de estudio: Evaluation_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Mol Imaging Biol Asunto de la revista: BIOLOGIA MOLECULAR / DIAGNOSTICO POR IMAGEM Año: 2006 Tipo del documento: Article País de afiliación: Países Bajos