Your browser doesn't support javascript.
loading
Multi-detection of corticosteroids in sports doping and veterinary control using high-resolution liquid chromatography/time-of-flight mass spectrometry.
Touber, M E; van Engelen, M C; Georgakopoulus, C; van Rhijn, J A; Nielen, M W F.
Afiliación
  • Touber ME; RIKILT-Institute of Food Safety, P.O. Box 230, Wageningen, 6700 AE, The Netherlands.
Anal Chim Acta ; 586(1-2): 137-46, 2007 Mar 14.
Article en En | MEDLINE | ID: mdl-17386705
A liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) method was developed using the latest high-resolution LC column technology, the ultra performance liquid chromatography (UPLC), and electrospray ionization (ESI) in the positive ion mode. Gradient UPLC separation conditions were optimized for a group of 22 analytes comprising 17 glucocorticosteroids, specific designer steroids such as tetrahydrogestrinone (THG) and specific beta2-agonists such as formoterol. The UPLC/TOFMS separation obtained required 5.5 min only for all the substances tested. Even the critical pair of dexamethasone and betamethasone isomers was almost completely resolved. Thanks to the over 10,000 full-width at half maximum (FWHM) mass resolution and high mass accuracy features of TOFMS 50 mDa window accurate mass chromatograms could be reconstructed for the individual analytes. Sensitive screening in human and calf urine samples fortified at the glucocorticosteroids minimum required performance limit (MRPL) of 30 microg L(-1) (human urine, sports doping) and 2 microg L(-1) (calf urine, veterinary control) could be obtained. The potential of UPLC/TOFMS for confirmatory analysis was shown by determining the accurate mass of all compounds and fragment ions upon in-source collision-induced dissociation (CID) at different energies. The exact mass measurement errors for all glucocorticosteroids were found to be within 6 ppm. Considering veterinary control, limits of detection (LOD) and limits of quantification (LOQ) were determined for most of the analytes in calf urine and found to range from 0.1 to 3.3 and from 0.4 to 4.4 microg L(-1), respectively. The method can be easily extended with other banned substances of interest, as demonstrated by the addition of 21 beta2-agonists to the original analyte mixture in urine, without causing any interferences.
Asunto(s)
Buscar en Google
Banco de datos: MEDLINE Asunto principal: Espectrometría de Masas / Medicina Veterinaria / Detección de Abuso de Sustancias / Cromatografía Liquida / Urinálisis / Corticoesteroides / Doping en los Deportes Tipo de estudio: Diagnostic_studies Límite: Animals / Humans Idioma: En Revista: Anal Chim Acta Año: 2007 Tipo del documento: Article País de afiliación: Países Bajos
Buscar en Google
Banco de datos: MEDLINE Asunto principal: Espectrometría de Masas / Medicina Veterinaria / Detección de Abuso de Sustancias / Cromatografía Liquida / Urinálisis / Corticoesteroides / Doping en los Deportes Tipo de estudio: Diagnostic_studies Límite: Animals / Humans Idioma: En Revista: Anal Chim Acta Año: 2007 Tipo del documento: Article País de afiliación: Países Bajos