PURPOSE: To evaluate whether real-time intraoperative ultrasound (US)-based dosimetry can replace conventional postoperative computed tomography (CT)-based dosimetry in prostate brachytherapy. METHODS AND MATERIALS: Between December 2001 and November 2002, 82 patients underwent (103)Pd prostate brachytherapy. An interplant treatment planning system was used for real-time intraoperative transrectal US-guided treatment planning. The dose distribution was updated according to the estimated seed position to obtain the dose-volume histograms. Postoperative CT-based dosimetry was performed a few hours later using the Theraplan-Plus treatment planning system. The dosimetric parameters obtained from the two imaging modalities were compared. RESULTS: The results of this study revealed correlations between the US- and CT-based dosimetry. However, large variations were found in the implant-quality parameters of the two modalities, including the doses covering 100%, 90%, and 80% of the prostate volume and prostate volumes covered by 100%, 150%, and 200% of the prescription dose. The mean relative difference was 38% and 16% for doses covering 100% and 90% of the prostate volume and 10% and 21% for prostate volumes covered by 100% and 150% of the prescription dose, respectively. The CT-based volume covered by 200% of the prescription dose was about 30% greater than the US-based one. Compared with CT-based dosimetry, US-based dosimetry significantly underestimated the dose to normal organs, especially for the rectum. The average US-based maximal dose and volume covered by 100% of the prescription dose for the rectum was 72 Gy and 0.01 cm(3), respectively, much lower than the 159 Gy and 0.65 cm(3) obtained using CT-based dosimetry. CONCLUSION: Although dosimetry using intraoperative US-based planning provides preliminary real-time information, it does not accurately reflect the postoperative CT-based dosimetry. Until studies have determined whether US-based dosimetry or postoperative CT-based dosimetry can better predict patient outcomes, the American Brachytherapy Society recommendation of CT-based postimplant dosimetry should remain the standard of care.
Buscar en Google
Banco de datos:
MEDLINE
Asunto principal:
Neoplasias de la Próstata
/
Braquiterapia
Tipo de estudio:
Diagnostic_studies
/
Evaluation_studies
/
Guideline
/
Prognostic_studies
Límite:
Humans
/
Male
Idioma:
En
Revista:
Int J Radiat Oncol Biol Phys
Año:
2008
Tipo del documento:
Article
País de afiliación:
Estados Unidos