Bone union rate with recombinant human bone morphogenic protein-2 versus autologous iliac bone in PEEK cages for anterior lumbar interbody fusion.
Flouzat-Lachaniette, Charles-Henri; Ghazanfari, Amir; Bouthors, Charlie; Poignard, Alexandre; Hernigou, Philippe; Allain, Jérôme.
Afiliación
  • Flouzat-Lachaniette CH; Hôpital Henri MONDOR, AP-HP - UPEC, Institut du Rachis - Service de Chirurgie Orthopédique et Traumatologique, 51, avenue du Maréchal de Lattre de Tassigny, 94010, Creteil Cedex, France, charles-henri.flouzat-lachaniette@hmn.aphp.fr.
Int Orthop ; 38(9): 2001-7, 2014 Sep.
Article en En | MEDLINE | ID: mdl-24627122
ABSTRACT

PURPOSE:

Autologous iliac crest bone graft (ICBG) is the gold standard material for spinal fusion. Bone graft substitutes, such as recombinant human bone morphogenic protein 2 (rhBMP-2) have been developed to promote spinal fusion and address morbidity issues related to ICBG harvesting. The objective of this study was to compare bone fusion rates after anterior lumbar interbody fusion (ALIF) between ICBG and rhBMP-2 by examining thin-cut computed tomography (CT) images at the one year follow-up.

METHODS:

Fifty one patients (62 levels) who underwent single- or two-level ALIF via the video-assisted minimally invasive anterior approach in our institution were assessed. Radiolucent cages were inserted in all cases. Each cage has a middle beam delimiting two chambers. Grafting was performed as follows one chamber was filled with autologous ICBG, and the other chamber was filled with 6 mg of rhBMP-2. Thin-cut CT-scan multiplanar reconstruction analyses were performed to assess the rate and quality of bone fusion at one year of follow-up.

RESULTS:

Fusion was observed in 55 levels (88.7 %), with significant differences in fusion rates with rhBMP-2 and ICBG (71 % vs. 88.7 %) (P=0.001). Osteogenesis in the rhBMP-2 chamber had a centripetal pattern in all cases, leaving a central void in 97.7 % of cases representing 38.3 % of the surface of its chamber (range 0-80.3 %). In ICBG chambers, graft resorption was present in 44.4 %, representing 9.8 % of the chamber surface (range 0-52.2 %).

CONCLUSION:

RhBMP-2 was inferior to ICBG in terms of rate and quality of bone fusion in one- or two-level ALIF.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Polietilenglicoles / Fusión Vertebral / Cámaras de Difusión de Cultivos / Trasplante Óseo / Proteína Morfogenética Ósea 2 / Ilion / Cetonas / Vértebras Lumbares Tipo de estudio: Observational_studies / Prognostic_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Int Orthop Año: 2014 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Polietilenglicoles / Fusión Vertebral / Cámaras de Difusión de Cultivos / Trasplante Óseo / Proteína Morfogenética Ósea 2 / Ilion / Cetonas / Vértebras Lumbares Tipo de estudio: Observational_studies / Prognostic_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Int Orthop Año: 2014 Tipo del documento: Article