Your browser doesn't support javascript.
loading
Effect of a novel temperature-controlled laminar airflow device on personal breathing zone aeroallergen exposure.
Gore, R B; Boyle, R J; Gore, C; Custovic, A; Hanna, H; Svensson, P; Warner, J O.
Afiliación
  • Gore RB; Manchester Academic Health Science Centre, University Hospitals of South Manchester, University of Manchester, Manchester, UK; East and North Herts NHS Trust, Stevenage, UK.
Indoor Air ; 25(1): 36-44, 2015 Feb.
Article en En | MEDLINE | ID: mdl-24750266
ABSTRACT
Temperature-controlled laminar airflow improves symptoms in atopic asthmatics, but its effects on personal allergen exposure are unknown. We aimed to evaluate its effects on personal cat allergen and particulate exposures in a simulated bedroom environment. Five healthy volunteers lay under an active and an inactive temperature-controlled laminar airflow device for 175 min, in a simulated bedroom containing bedding from a cat owner. Total airborne particles (≥0.5 - ≥10 µm diameter) were quantified with a laser particle counter. Airborne allergen was sampled with Institute of Occupational Medicine filters. Inhaled exposure was sampled with nasal air samplers. Allergen-containing particles were quantified by immunoassay. Treatment reduced total airborne particles (>0.5 µm diameter) by >99% (P < 0.001) and reduced airborne allergen concentration within the breathing zone (ratio of median counts = 30, P = 0.043). Treatment reduced inhaled allergen (ratio of median counts = 7, P = 0.043). Treatment was not associated with a change in airborne allergen concentration outside of the breathing zone (P = 0.160). Temperature-controlled laminar airflow treatment of individuals in an allergen-rich experimental environment results in significant reductions in breathing zone allergenic and non-allergenic particle exposure, and in inhaled cat allergen exposure. These findings may explain the clinical benefits of temperature-controlled laminar airflow.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Ambiente Controlado / Hipersensibilidad Límite: Animals / Humans País/Región como asunto: Europa Idioma: En Revista: Indoor Air Asunto de la revista: SAUDE AMBIENTAL Año: 2015 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Ambiente Controlado / Hipersensibilidad Límite: Animals / Humans País/Región como asunto: Europa Idioma: En Revista: Indoor Air Asunto de la revista: SAUDE AMBIENTAL Año: 2015 Tipo del documento: Article País de afiliación: Reino Unido