Development and validation of a high performance liquid chromatography method for determination of 6-benzyl-1-benzyloxymethyl-5-iodouracil (W-1), a novel non-nucleoside reverse transcriptase inhibitor and its application to a pharmacokinetic study in rats.
Lu, Ying-Yuan; Wang, Xin; Wang, Xiao-Wei; Liu, Jun-Yi; Li, Pu; Ren, Hong; Lou, Ya-Qing; Lu, Chuang; Zhang, Guo-Liang.
Afiliación
  • Lu YY; Department of Pharmacology, Basic Medical School, Beijing (Peking) University, Beijing, 100191, People's Republic of China.
  • Wang X; Department of Pharmacology, Basic Medical School, Beijing (Peking) University, Beijing, 100191, People's Republic of China.
  • Wang XW; Department of Chemical Biology, School of Pharmaceutical Sciences, Beijing (Peking) University, Beijing, 100191, People's Republic of China.
  • Liu JY; Department of Chemical Biology, School of Pharmaceutical Sciences, Beijing (Peking) University, Beijing, 100191, People's Republic of China.
  • Li P; Department of Pharmacology, Basic Medical School, Beijing (Peking) University, Beijing, 100191, People's Republic of China.
  • Ren H; Department of Pharmacology, Basic Medical School, Beijing (Peking) University, Beijing, 100191, People's Republic of China.
  • Lou YQ; Department of Pharmacology, Basic Medical School, Beijing (Peking) University, Beijing, 100191, People's Republic of China.
  • Lu C; Millennium Pharmaceuticals-Takeda, Cambridge, Massachusetts, USA.
  • Zhang GL; Department of Pharmacology, Basic Medical School, Beijing (Peking) University, Beijing, 100191, People's Republic of China.
Biomed Chromatogr ; 29(10): 1548-52, 2015 Oct.
Article en En | MEDLINE | ID: mdl-25808138
ABSTRACT
A sensitive and selective high-performance liquid chromatographic (HPLC) method for determination of 6-benzyl-1-benzyloxymethyl-5-iodouracil (W-1), a novel non-nucleoside reverse transcriptase inhibitor in rat plasma, was developed and validated. Chromatographic separation of W-1 and megestrol acetate (internal standard) was achieved on a reversed-phase C18 column at 25°C. The mobile phase was consisted of acetonitrile-water (6040, v/v) and pumped at a flow rate of 1.0 mL/min. The ultraviolet (UV) detector was set at the absorption wavelength of 284 nm. The calibration curve for W-1 was linear over the concentration range of 0.01-8 µg/mL and the lower limit of quantification was 10 ng/mL. The intra- and inter-day precision and accuracy were <8.9 and 5.3%, respectively. The extraction recoveries ranged from 97.9 to 101.6%. The validated HPLC method was successfully applied to a pharmacokinetic study of W-1 in rats.