Your browser doesn't support javascript.
loading
Detection of Small Pulmonary Nodules with Ultrashort Echo Time Sequences in Oncology Patients by Using a PET/MR System.
Burris, Nicholas S; Johnson, Kevin M; Larson, Peder E Z; Hope, Michael D; Nagle, Scott K; Behr, Spencer C; Hope, Thomas A.
Afiliación
  • Burris NS; From the Department of Radiology (N.S.B., P.E.Z.L., M.D.H., S.C.B., T.A.H.), University of California-San Francisco, 505 Parnassus Ave, Box 0628, San Francisco, CA 94143-0628; Departments of Medical Physics (K.M.J., S.K.N.), Radiology (S.K.N.), and Pediatrics (S.K.N.), University of Wisconsin, Madis
  • Johnson KM; From the Department of Radiology (N.S.B., P.E.Z.L., M.D.H., S.C.B., T.A.H.), University of California-San Francisco, 505 Parnassus Ave, Box 0628, San Francisco, CA 94143-0628; Departments of Medical Physics (K.M.J., S.K.N.), Radiology (S.K.N.), and Pediatrics (S.K.N.), University of Wisconsin, Madis
  • Larson PE; From the Department of Radiology (N.S.B., P.E.Z.L., M.D.H., S.C.B., T.A.H.), University of California-San Francisco, 505 Parnassus Ave, Box 0628, San Francisco, CA 94143-0628; Departments of Medical Physics (K.M.J., S.K.N.), Radiology (S.K.N.), and Pediatrics (S.K.N.), University of Wisconsin, Madis
  • Hope MD; From the Department of Radiology (N.S.B., P.E.Z.L., M.D.H., S.C.B., T.A.H.), University of California-San Francisco, 505 Parnassus Ave, Box 0628, San Francisco, CA 94143-0628; Departments of Medical Physics (K.M.J., S.K.N.), Radiology (S.K.N.), and Pediatrics (S.K.N.), University of Wisconsin, Madis
  • Nagle SK; From the Department of Radiology (N.S.B., P.E.Z.L., M.D.H., S.C.B., T.A.H.), University of California-San Francisco, 505 Parnassus Ave, Box 0628, San Francisco, CA 94143-0628; Departments of Medical Physics (K.M.J., S.K.N.), Radiology (S.K.N.), and Pediatrics (S.K.N.), University of Wisconsin, Madis
  • Behr SC; From the Department of Radiology (N.S.B., P.E.Z.L., M.D.H., S.C.B., T.A.H.), University of California-San Francisco, 505 Parnassus Ave, Box 0628, San Francisco, CA 94143-0628; Departments of Medical Physics (K.M.J., S.K.N.), Radiology (S.K.N.), and Pediatrics (S.K.N.), University of Wisconsin, Madis
  • Hope TA; From the Department of Radiology (N.S.B., P.E.Z.L., M.D.H., S.C.B., T.A.H.), University of California-San Francisco, 505 Parnassus Ave, Box 0628, San Francisco, CA 94143-0628; Departments of Medical Physics (K.M.J., S.K.N.), Radiology (S.K.N.), and Pediatrics (S.K.N.), University of Wisconsin, Madis
Radiology ; 278(1): 239-46, 2016 Jan.
Article en En | MEDLINE | ID: mdl-26133050
ABSTRACT

PURPOSE:

To investigate the utility of a free-breathing ultrashort echo time (UTE) sequence for the evaluation of small pulmonary nodules in oncology patients by using a hybrid positron emission tomography (PET)/magnetic resonance (MR) imaging system and to compare the nodule detection rate between UTE and a conventional three-dimensional gradient-recalled-echo (GRE) technique. MATERIALS AND

METHODS:

In this HIPAA-compliant, institutional review board-approved prospective study, 82 pulmonary nodules were identified in eight patients with extrathoracic malignancies. Patients underwent free-breathing UTE and dual-echo three-dimensional GRE imaging of the lungs in a hybrid PET/MR imaging unit immediately after clinical PET/computed tomography (CT). CT was considered the reference standard for nodule detection. Two reviewers identified nodules and obtained measurements on MR images. The McNemar test was used to evaluate differences in nodule detection rate between MR techniques, and interrater agreement was assessed by using Bland-Altman plots.

RESULTS:

Mean nodule diameter ± standard deviation was 6.2 mm ± 2.7 (range, 3-17 mm). The detection rate was higher for UTE imaging than for dual-echo GRE imaging for nodules of at least 4 mm (82% vs 34%, respectively; P < .001), with the largest difference in detection noted in the 4-8-mm nodule group (79% vs 21%, P < .001). UTE imaging displayed a higher detection rate than dual-echo GRE imaging for nodules without fluorodeoxyglucose avidity (68% vs 22%, respectively; P < .001). Interrater reliability of nodule detection with MR imaging was high (κ = 0.90 for UTE imaging and κ = 0.92 for dual-echo GRE imaging).

CONCLUSION:

A free-breathing UTE sequence has high sensitivity for the detection of small pulmonary nodules (4-8 mm) and outperformed a three-dimensional dual-echo GRE technique for the detection of small, non-fluorodeoxyglucose-avid nodules.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Nódulos Pulmonares Múltiples / Imagen Multimodal / Neoplasias Pulmonares Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Radiology Año: 2016 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Nódulos Pulmonares Múltiples / Imagen Multimodal / Neoplasias Pulmonares Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Radiology Año: 2016 Tipo del documento: Article