Your browser doesn't support javascript.
loading
Assessment of electrocardiographic parameters in patients with electrocution injury.
Karatas, Mehmet Baran; Onuk, Tolga; Güngör, Baris; Ipek, Göktürk; Özcan, Kazim Serhan; Kaplangöray, Mustafa; Çanga, Yigit; Durmus, Gündüz; Çakilli, Yasin; Bolca, Osman.
Afiliación
  • Karatas MB; Department of Cardiology, Siyami Ersek Thoracic and Cardiovascular Surgery Center, Training and Research Hospital, Istanbul, Turkey.
  • Onuk T; Department of Cardiology, Siyami Ersek Thoracic and Cardiovascular Surgery Center, Training and Research Hospital, Istanbul, Turkey.
  • Güngör B; Department of Cardiology, Siyami Ersek Thoracic and Cardiovascular Surgery Center, Training and Research Hospital, Istanbul, Turkey. Electronic address: drbarisgungor@gmail.com.
  • Ipek G; Department of Cardiology, Siyami Ersek Thoracic and Cardiovascular Surgery Center, Training and Research Hospital, Istanbul, Turkey.
  • Özcan KS; Department of Cardiology, Derince Training and Research Hospital, Kocaeli, Turkey.
  • Kaplangöray M; Department of Cardiology, Sanliurfa Mehmet Akif Inan Training and Research Hospital, Sanliurfa, Turkey.
  • Çanga Y; Department of Cardiology, Kartal Yavuz Selim Hospital, Istanbul, Turkey.
  • Durmus G; Department of Cardiology, Arnavutköy State Hospital, Istanbul, Turkey.
  • Çakilli Y; Department of Cardiology, Siyami Ersek Thoracic and Cardiovascular Surgery Center, Training and Research Hospital, Istanbul, Turkey.
  • Bolca O; Department of Cardiology, Siyami Ersek Thoracic and Cardiovascular Surgery Center, Training and Research Hospital, Istanbul, Turkey.
J Electrocardiol ; 48(5): 809-14, 2015.
Article en En | MEDLINE | ID: mdl-26209300
ABSTRACT

BACKGROUND:

Electrocution injury (EI) is a major problem in developing countries. The aim of this study is to investigate the effect of EI on electrocardiographic (ECG) parameters.

METHODS:

A total of 43 patients hospitalized with diagnosis of EI were prospectively enrolled. Admission ECGs were compared with follow-up ECGs obtained one month after the event.

RESULTS:

Maximum P wave duration (Pmax), minimum P wave duration (Pmin), P wave dispersion (PWD), PR interval, QRS complex duration, corrected QT duration (QTc), QT dispersion (QTD), T peak to T end (Tp-e) interval were longer and Tp-e interval/QT and Tp-e interval/QTc ratios were higher on admission ECGs compared to follow-up ECGs. Frontal QRS-T angle and frequency of patients with fragmented QRS were also higher on admission ECGs.

CONCLUSION:

Our study revealed that EI causes significant deterioration of admission ECG parameters. The clinical use of these parameters in prediction of arrhythmias after EI warrants further studies.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Arritmias Cardíacas / Diagnóstico por Computador / Traumatismos por Electricidad / Electrocardiografía / Lesiones Cardíacas Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: J Electrocardiol Año: 2015 Tipo del documento: Article País de afiliación: Turquía

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Arritmias Cardíacas / Diagnóstico por Computador / Traumatismos por Electricidad / Electrocardiografía / Lesiones Cardíacas Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: J Electrocardiol Año: 2015 Tipo del documento: Article País de afiliación: Turquía