Spontaneous Sealing of a Type Ia Endoleak after Ovation Stent Graft Implantation in a Patient with On-Label Aortic Neck Anatomy.
Ann Vasc Surg
; 34: 270.e19-24, 2016 Jul.
Article
en En
| MEDLINE
| ID: mdl-27174349
We report a case of an early type Ia endoleak after endovascular aneurysm repair (EVAR) of an abdominal aortic aneurysm by Ovation Stent Graft implantation and spontaneously resolved without further reintervention. The patient presents a conical aortic neck, but EVAR was performed within the instruction for use proposed by manufactory. At completion angiography, a low-flow type Ia endoleak was present and left untreated. Computed tomographic angiography performed on the third postoperative day showed infolding of the 2 sealing rings. The patient was dismissed without further treatment. At 3-month follow-up, the leak appeared spontaneously sealed with partial expansion of the 2 rings.
Texto completo:
1
Banco de datos:
MEDLINE
Asunto principal:
Prótesis Vascular
/
Stents
/
Aneurisma de la Aorta Abdominal
/
Implantación de Prótesis Vascular
/
Endofuga
/
Procedimientos Endovasculares
Límite:
Aged
/
Humans
/
Male
Idioma:
En
Revista:
Ann Vasc Surg
Asunto de la revista:
ANGIOLOGIA
Año:
2016
Tipo del documento:
Article