Your browser doesn't support javascript.
loading
Usefulness of optic nerve ultrasound to predict clinical progression in multiple sclerosis. / Utilidad de la ecografía de nervio óptico como predictor de progresión en esclerosis múltiple.
Pérez Sánchez, S; Eichau Madueño, S; Rus Hidalgo, M; Domínguez Mayoral, A M; Vilches-Arenas, A; Navarro Mascarell, G; Izquierdo, G.
Afiliación
  • Pérez Sánchez S; Servicio de Neurología, Hospital Universitario Virgen Macarena, Sevilla, España. Electronic address: soledad.perez.sanchez@gmail.com.
  • Eichau Madueño S; Servicio de Neurología, Hospital Universitario Virgen Macarena, Sevilla, España.
  • Rus Hidalgo M; Servicio de Neurología, Hospital Universitario Virgen Macarena, Sevilla, España.
  • Domínguez Mayoral AM; Servicio de Neurología, Hospital Universitario Virgen Macarena, Sevilla, España.
  • Vilches-Arenas A; Servicio de Medicina Preventiva, Hospital Universitario Virgen Macarena, Sevilla, España.
  • Navarro Mascarell G; Servicio de Neurología, Hospital Universitario Virgen Macarena, Sevilla, España.
  • Izquierdo G; Servicio de Neurología, Hospital Universitario Virgen Macarena, Sevilla, España.
Neurologia (Engl Ed) ; 36(3): 209-214, 2021 Apr.
Article en En, Es | MEDLINE | ID: mdl-29573900
ABSTRACT

INTRODUCTION:

Progressive neuronal and axonal loss are considered the main causes of disability in patients with multiple sclerosis (MS). The disease frequently involves the visual system; the accessibility of the system for several functional and structural tests has made it a model for the in vivo study of MS pathogenesis. Orbital ultrasound is a non-invasive technique that enables various structures of the orbit, including the optic nerve, to be evaluated in real time. MATERIAL AND

METHODS:

We conducted an observational, ambispective study of MS patients. Disease progression data were collected. Orbital ultrasound was performed on all patients, with power set according to the 'as low as reasonably achievable' (ALARA) principle. Optical coherence tomography (OCT) data were also collected for those patients who underwent the procedure. Statistical analysis was conducted using SPSS version 22.0.

RESULTS:

Disease progression was significantly correlated with ultrasound findings (P=.041 for the right eye and P=.037 for the left eye) and with Expanded Disability Status Scale (EDSS) score at the end of the follow-up period (P=.07 for the right eye and P=.043 for the left eye). No statistically significant differences were found with relation to relapses or other clinical variables.

DISCUSSION:

Ultrasound measurement of optic nerve diameter constitutes a useful, predictive factor for the evaluation of patients with MS. Smaller diameters are associated with poor clinical progression and greater disability (measured by EDSS).
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Nervio Óptico / Esclerosis Múltiple Tipo de estudio: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En / Es Revista: Neurologia (Engl Ed) Año: 2021 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Nervio Óptico / Esclerosis Múltiple Tipo de estudio: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En / Es Revista: Neurologia (Engl Ed) Año: 2021 Tipo del documento: Article