Your browser doesn't support javascript.
loading
Advanced image processing with fusion and calcification enhancement in transcatheter aortic valve implantation: impact on radiation exposure.
Overtchouk, Pavel; Sudre, Arnaud; Delhaye, Cédric; Juthier, Francis; Van Belle, Eric; Coisne, Augustin; Koussa, Mohamad; Mylotte, Darren; Modine, Thomas.
Afiliación
  • Overtchouk P; Department of Cardiology and Cardiovascular Surgery, Institut Coeur Poumon, Centre Hospitalier Regional et Universitaire de Lille, Lille, France.
  • Sudre A; Department of Cardiology and Cardiovascular Surgery, Institut Coeur Poumon, Centre Hospitalier Regional et Universitaire de Lille, Lille, France.
  • Delhaye C; Department of Cardiology and Cardiovascular Surgery, Institut Coeur Poumon, Centre Hospitalier Regional et Universitaire de Lille, Lille, France.
  • Juthier F; Department of Cardiology and Cardiovascular Surgery, Institut Coeur Poumon, Centre Hospitalier Regional et Universitaire de Lille, Lille, France.
  • Van Belle E; INSERM UMR 1011, Lille, France.
  • Coisne A; Faculté de Médecine, Université de Lille 2, Lille, France.
  • Koussa M; Department of Cardiology and Cardiovascular Surgery, Institut Coeur Poumon, Centre Hospitalier Regional et Universitaire de Lille, Lille, France.
  • Mylotte D; INSERM UMR 1011, Lille, France.
  • Modine T; Faculté de Médecine, Université de Lille 2, Lille, France.
Interact Cardiovasc Thorac Surg ; 27(4): 512-519, 2018 10 01.
Article en En | MEDLINE | ID: mdl-29688455
OBJECTIVES: Radiation exposure is a concern for both patients and operators during transcatheter aortic valve implantation (TAVI). Efforts to reduce radiation dose are warranted. We aimed at investigating if per-operative advanced image processing can reduce patient and operator irradiation use during TAVI. METHODS: We performed a prospective single-centre observational study comparing patient and operator radiation exposure using standard fluoroscopy (control group) or a novel technology of live advanced fluoroscopic image processing (test group) among consecutive patients undergoing TAVI between August 2015 and April 2016. Patient irradiation (dose-area product, effective dose and air kerma), contrast media volume and clinical outcomes were assessed. RESULTS: Among 152 elderly [median age (interquartile range): 83 (78-87)] patients (n = 76 per group) undergoing TAVI, baseline clinical characteristics were similar between the control and test groups, except for a higher median EuroSCORE II (2.8% vs 2.3%, P = 0.02) and higher rate of TAVI for failing surgical bioprosthesis (11.8% vs 2.6%, P = 0.03) in the control group. The dose-area product was reduced in the test group: mean reduction of -27.5 Gy × cm2 [95% confidence intervals (CIs): 15.9-39.1, P < 0.001]. Furthermore, effective dose [mean reduction -6.5 (95% CI: 5.9-7.2) mSv, P < 0.001] and air kerma [mean reduction -167.5 (95% CI 163.4-177.3) mGy, P < 0.001] were lower in the test group. Fluoroscopy time, contrast volume and clinical outcomes were similar. CONCLUSIONS: Patient radiation exposure was significantly reduced using a novel live advanced fluoroscopy image processing with calcification enhancement and fusion of the virtual aortic annulus without compromising patient safety.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Procesamiento de Imagen Asistido por Computador / Calcinosis / Fluoroscopía / Exposición a la Radiación / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Interact Cardiovasc Thorac Surg Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Procesamiento de Imagen Asistido por Computador / Calcinosis / Fluoroscopía / Exposición a la Radiación / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Interact Cardiovasc Thorac Surg Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Francia