Your browser doesn't support javascript.
loading
Predicting Hepatic Steatosis in Living Liver Donors Via Controlled Attenuation Parameter.
Yen, Y H; Kuo, F Y; Lin, C C; Chen, C L; Chang, K C; Tsai, M C; Hu, T H.
Afiliación
  • Yen YH; Division of Hepatogastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung, Taiwan.
  • Kuo FY; Department of Pathology, Chang Gung Memorial Hospital-Kaohsiung Medical Center, Chang Gung University College of Medicine, Kaohsiung, Taiwan.
  • Lin CC; Liver Transplantation Center and Department of Surgery, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan.
  • Chen CL; Liver Transplantation Center and Department of Surgery, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan.
  • Chang KC; Division of Hepatogastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung, Taiwan.
  • Tsai MC; Division of Hepatogastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung, Taiwan.
  • Hu TH; Division of Hepatogastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung, Taiwan. Electronic address: dr.hu@msa.hinet.net.
Transplant Proc ; 50(10): 3533-3538, 2018 Dec.
Article en En | MEDLINE | ID: mdl-30577232
ABSTRACT

BACKGROUND:

Hepatic steatosis (HS) can cause substantial problems for both donors and recipients in living donor liver transplantation. The controlled attenuation parameter (CAP) is a noninvasive method of measuring HS using a process based on transient elastography.

AIM:

To evaluate the accuracy of CAP in quantifying HS during living donor liver transplantation.

METHODS:

A total of 54 liver donors who received CAP and intraoperative liver biopsy (LB) were enrolled in this study. The performance of CAP compared with LB for diagnosing HS was assessed using areas under receiver operating characteristic curves. HS was defined by the presence of steatosis in >5% of hepatocytes.

RESULTS:

No HS was found in 47 donors, while the remaining 7 donors showed HS ranging from 10% to 30%. Using CAP, the area under receiver operating characteristic curve was 0.96 (95% CI, 0.91-1; P < .001) for HS; the optimal cutoff value for HS was 257 dB/m (sensitivity 100%, specificity 89.4%, positive predictive value 58.3%, negative predictive value 100%). Among the 42 candidates with CAP <257 dB/m, none had HS, while of the 12 candidates with CAP ≥257 dB/m, 7 had HS. In a multivariate linear regression analyses, body mass index (ß = 0.71, P < .001) was found to be independently associated with CAP in those without HS.

CONCLUSIONS:

CAP might be a promising tool to exclude HS in East Asian living liver donors. Body mass index was found to be independently associated with CAP values in those without HS.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Trasplante de Hígado / Donadores Vivos / Trasplantes / Diagnóstico por Imagen de Elasticidad / Hígado Graso Tipo de estudio: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Transplant Proc Año: 2018 Tipo del documento: Article País de afiliación: Taiwán

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Trasplante de Hígado / Donadores Vivos / Trasplantes / Diagnóstico por Imagen de Elasticidad / Hígado Graso Tipo de estudio: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Transplant Proc Año: 2018 Tipo del documento: Article País de afiliación: Taiwán