Your browser doesn't support javascript.
loading
High-Flux versus High-Retention-Onset Membranes: In vivo Small and Middle Molecules Kinetics in Convective Dialysis Modalities.
Cordeiro, Isis S F; Cordeiro, Lilian; Wagner, Carolina S; Araújo, Luiza Karla R P; Pereira, Benedito J; Abensur, Hugo; Elias, Rosilene M; Silva, Bruno C.
Afiliación
  • Cordeiro ISF; Renal Division, Department of Medicine, Hospital das Clinicas HCFMUSP, Universidade de São Paulo, São Paulo, Brazil.
  • Cordeiro L; Renal Division, Department of Medicine, Hospital das Clinicas HCFMUSP, Universidade de São Paulo, São Paulo, Brazil.
  • Wagner CS; Renal Division, Department of Medicine, Hospital das Clinicas HCFMUSP, Universidade de São Paulo, São Paulo, Brazil.
  • Araújo LKRP; Renal Division, Department of Medicine, Hospital das Clinicas HCFMUSP, Universidade de São Paulo, São Paulo, Brazil.
  • Pereira BJ; Renal Division, Department of Medicine, Hospital das Clinicas HCFMUSP, Universidade de São Paulo, São Paulo, Brazil.
  • Abensur H; Nephrology Division, Universidade Nove de Julho (UNINOVE), São Paulo, Brazil.
  • Elias RM; Renal Division, Department of Medicine, Hospital das Clinicas HCFMUSP, Universidade de São Paulo, São Paulo, Brazil.
  • Silva BC; Renal Division, Department of Medicine, Hospital das Clinicas HCFMUSP, Universidade de São Paulo, São Paulo, Brazil.
Blood Purif ; 49(1-2): 8-15, 2020.
Article en En | MEDLINE | ID: mdl-31362299
BACKGROUND: Patients undergoing maintenance hemodialysis (HD) exhibit increased levels of uremic toxins, which are associated with poor outcomes. Recently, new dialysis membranes have allowed clearance of solutes with higher molecular weight, without significant albumin losses high-retention-onset-HD (HRO-HD). METHODS: Prospective crossover trial, in which 16 prevalent patients switched from high-flux HD (HF-HD) to online hemodiafiltration (olHDF) and HRO-HD for 4 weeks. The following variables were evaluated: pre- and post-dialysis serum concentrations of albumin, urea, phosphate (P), beta-2 microglobulin (ß2M), and total mass (TM) extraction and dialyzer clearance of urea, P, and ß2M. RESULTS: Comparing HF-HD, olHDF, and HRO-HD, respectively, there were no differences regarding pre-dialysis serum concentrations of albumin (3.94 ± 0.36, 4.06 ± 0.22, and 3.93 ± 0.41 g/dL, p = 0.495), urea (166 ± 29, 167 ± 30, and 164 ± 27 mg/dL, p = 0.971), P (4.9 ± 2.1, 5.2 ± 1.6, and 4.9 ± 2.1 mg/dL, p = 0.879), and ß2M (31.3 ± 7.1, 32.6 ± 8.6, and 33.7 ± 5.9 µg/mL, p = 0.646). ß2M clearance was significantly lower in HF-HD in comparison to both olHDF and HRO-HD: 43 (37-53) versus 64 (48-85) mL/min, p = 0.013, and 69 (58-86) mL/min, p = 0.015, respectively. Post-dialysis ß2M serum concentration was higher in HF-HD in comparison to olHDF and HRO-HD: 11.6 (9.6-12.4) vs. 5.7 (4.5-7.0) µg/mL, p = 0.001, and 5.6 (5.3-7.6) µg/mL, p = 0.001, respectively. TM extraction of urea, P, and ß2M were similar across the 3 dialysis modalities. CONCLUSIONS: olHDF and HRO-HD were superior to HF-HD regarding ß2M clearance, leading to lower post-dialysis ß2M levels.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Urea / Microglobulina beta-2 / Hemodiafiltración / Membranas Artificiales Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Blood Purif Año: 2020 Tipo del documento: Article País de afiliación: Brasil

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Urea / Microglobulina beta-2 / Hemodiafiltración / Membranas Artificiales Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Blood Purif Año: 2020 Tipo del documento: Article País de afiliación: Brasil