Your browser doesn't support javascript.
loading
Effect of Instrumentation Techniques and Kinematics on Apical Extrusion of Debris: An In Vitro Study.
Haridas, Kaushik; Hariharan, Madhu; Singh, Prabath; Varughese, Anju; Ravi, Arjun B; Varma, K Ravi.
Afiliación
  • Haridas K; Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vidya Vishwapeetham, AIMS, Kochi, Kerala, India, Phone: +91 4242801234, e-mail: drkaushikendo@gmail.com.
  • Hariharan M; Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vidya Vishwapeetham, AIMS, Kochi, Kerala, India.
  • Singh P; Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vidya Vishwapeetham, AIMS, Kochi, Kerala, India.
  • Varughese A; Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vidya Vishwapeetham, AIMS, Kochi, Kerala, India.
  • Ravi AB; Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vidya Vishwapeetham, AIMS, Kochi, Kerala, India.
  • Varma KR; Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vidya Vishwapeetham, AIMS, Kochi, Kerala, India.
J Contemp Dent Pract ; 20(9): 1067-1070, 2019 Sep 01.
Article en En | MEDLINE | ID: mdl-31797831
ABSTRACT

AIM:

To evaluate the effect of instrumentation kinematics on debris extrusion by comparing the amount of apically extruded debris after canal preparation using ProTaper next in continuous rotation as well as forward reciprocating motion and WaveOne gold in reverse reciprocating motion. MATERIALS AND

METHODS:

We randomly divided ninety buccal roots of maxillary bicuspids with fully formed apices into three groups. After achieving the coronal access, the patency of the root canals was established with a size 10 K file. The canals were then instrumented using ProTaper next in continuous rotation or in a forward reciprocating motion and WaveOne gold in reverse reciprocating motion. Eppendorf tubes were used to collect the debris extruded through the apical foramen. The tubes were placed in a -80° freezer for 8 hours and then in a lyophilizer for 24 hours. The quantity of the apically extruded debris was assessed by subtracting the weights of Eppendorf tubes before and after instrumentation. The analysis was done using a one-way ANOVA test and the Bonferroni test to compare the groups.

RESULTS:

The mean weight of extruded debris with WaveOne gold in reverse reciprocation was significantly lower than ProTaper next in forward reciprocation and ProTaper next in continuous rotation (p value = <0.001).

CONCLUSION:

WaveOne gold in reverse reciprocation was associated with a significantly lower amount of apical extrusion of debris than ProTaper next rotary files in forward reciprocation and continuous rotation. CLINICAL

SIGNIFICANCE:

According to the results of this study, reciprocating instrumentation technique was associated with a less amount of debris extrusion compared to continuous rotation.
Asunto(s)
Palabras clave
Buscar en Google
Banco de datos: MEDLINE Asunto principal: Preparación del Conducto Radicular / Cavidad Pulpar Idioma: En Revista: J Contemp Dent Pract Asunto de la revista: ODONTOLOGIA Año: 2019 Tipo del documento: Article
Buscar en Google
Banco de datos: MEDLINE Asunto principal: Preparación del Conducto Radicular / Cavidad Pulpar Idioma: En Revista: J Contemp Dent Pract Asunto de la revista: ODONTOLOGIA Año: 2019 Tipo del documento: Article