Your browser doesn't support javascript.
loading
Systematic analysis of button batteries', euro coins', and disk magnets' radiographic characteristics and the implications for the differential diagnosis of round radiopaque foreign bodies in the esophagus.
Meyer, Till Jasper; Grunz, Jan-Peter; Taeger, Johannes; Rak, Kristen; Hagen, Rudolf; Hackenberg, Stephan; Völker, Johannes; Scherzad, Agmal.
Afiliación
  • Meyer TJ; Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, University Hospital Wuerzburg, Josef-Schneider-Str. 11, Wuerzburg, D-97080, Germany. Electronic address: meyer_t2@ukw.de.
  • Grunz JP; Department of Diagnostic and Interventional Radiology, University Hospital Wuerzburg, Oberduerrbacher Str. 6, Wuerzburg, D-97080, Germany. Electronic address: grunz_j@ukw.de.
  • Taeger J; Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, University Hospital Wuerzburg, Josef-Schneider-Str. 11, Wuerzburg, D-97080, Germany. Electronic address: taeger_j@ukw.de.
  • Rak K; Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, University Hospital Wuerzburg, Josef-Schneider-Str. 11, Wuerzburg, D-97080, Germany. Electronic address: rak_k@ukw.de.
  • Hagen R; Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, University Hospital Wuerzburg, Josef-Schneider-Str. 11, Wuerzburg, D-97080, Germany. Electronic address: hagen_r@ukw.de.
  • Hackenberg S; Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, University Hospital Wuerzburg, Josef-Schneider-Str. 11, Wuerzburg, D-97080, Germany. Electronic address: hackenberg_s@ukw.de.
  • Völker J; Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, University Hospital Wuerzburg, Josef-Schneider-Str. 11, Wuerzburg, D-97080, Germany. Electronic address: voelker_j@ukw.de.
  • Scherzad A; Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, University Hospital Wuerzburg, Josef-Schneider-Str. 11, Wuerzburg, D-97080, Germany. Electronic address: scherzad_a@ukw.de.
Int J Pediatr Otorhinolaryngol ; 132: 109917, 2020 May.
Article en En | MEDLINE | ID: mdl-32032915
ABSTRACT

OBJECTIVES:

Button battery (BB) ingestion can cause life-threatening complications such as esophageal perforation, and mediastinitis. Chest radiography is the method of choice to diagnose BB ingestion. Therefore, an adequate interpretation of X-ray imaging by physicians is mandatory. The study aimed to analyze relevant diagnostic aspects of BB X-ray imaging, and retrospective analysis of the imaging of radiopaque foreign bodies.

METHODS:

All commercially available BBs and different foreign bodies such as euro coins (EC) and disk magnets (DM) were listed according to their sizes and compositions. Furthermore, an X-ray analysis of a test set of BBs, ECs and DMs was performed at angles of 0°, 45°, and 90°. Retrospective assessment of radiological characteristics was performed for patients with a round and radiopaque foreign body in the esophagus

RESULTS:

Only BBs with a diameter of at least 20 mm had a reliable positive double rim sign at scan angles of 90°, and 45°. The step-off effect was visible in all BBs regardless of the diameter. DMs and ECs presented a homogeneous X-ray weakening at all investigated scan angles. In the retrospective analysis all five cases of BB ingestion showed a double rim sign, all fifteen cases of coin ingestion a homogeneous X-ray weakening. A corrugated margin was detected for 10 cent, 20 cent and 50 cent coins.

CONCLUSIONS:

BBs with a diameter of at least 20 mm showed, depending on the battery model, a more or less pronounced double rim sign and step-off effect in conventional X-ray imaging. However the double rim sign can be simulated by for example a pot magnet.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Suministros de Energía Eléctrica / Radiografía / Esófago / Imanes / Cuerpos Extraños / Numismática Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Child, preschool / Humans Idioma: En Revista: Int J Pediatr Otorhinolaryngol Año: 2020 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Suministros de Energía Eléctrica / Radiografía / Esófago / Imanes / Cuerpos Extraños / Numismática Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Child, preschool / Humans Idioma: En Revista: Int J Pediatr Otorhinolaryngol Año: 2020 Tipo del documento: Article