Effect of hydrofluoric acid-based etchant at an elevated temperature on the bond strength and surface topography of Y-TZP ceramics.
Yu, Mi-Kyung; Lim, Myung-Jin; Na, Noo-Ri; Lee, Kwang-Won.
Afiliación
  • Yu MK; Department of Conservative Dentistry, School of Dentistry, Chonbuk National University, Jeonju, Korea.
  • Lim MJ; Department of Conservative Dentistry, School of Dentistry, Chonbuk National University, Jeonju, Korea.
  • Na NR; Department of Conservative Dentistry, School of Dentistry, Chonbuk National University, Jeonju, Korea.
  • Lee KW; Department of Conservative Dentistry, School of Dentistry, Chonbuk National University, Jeonju, Korea.
Restor Dent Endod ; 45(1): e6, 2020 Feb.
Article en En | MEDLINE | ID: mdl-32110535
OBJECTIVES: This study investigated the effects of a hydrofluoric acid (HA; solution of hydrogen fluoride [HF] in water)-based smart etching (SE) solution at an elevated temperature on yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) ceramics in terms of bond strength and morphological changes. MATERIALS AND METHODS: Eighty sintered Y-TZP specimens were prepared for shear bond strength (SBS) testing. The bonding surface of the Y-TZP specimens was treated with 37% phosphoric acid etching at 20°C-25°C, 4% HA etching at 20°C-25°C, or HA-based SE at 70°C-80°C. In all groups, zirconia primers were applied to the bonding surface of Y-TZP. For each group, 2 types of resin cement (with or without methacryloyloxydecyl dihydrogen phosphate [MDP]) were used. SBS testing was performed. Topographic changes of the etched Y-TZP surface were analyzed using scanning electron microscopy and atomic force microscopy. The results were analyzed and compared using 2-way analysis of variance. RESULTS: Regardless of the type of resin cement, the highest bond strength was measured in the SE group, with significant differences compared to the other groups (p < 0.05). In all groups, MDP-containing resin cement yielded significantly higher bond strength values than MDP-free resin cement (p < 0.05). It was also shown that the Y-TZP surface was etched by the SE solution, causing a large change in the surface topography. CONCLUSIONS: Bond strength significantly improved when a heated HA-based SE solution was applied to the Y-TZP surface, and the etched Y-TZP surface was more irregular and had higher surface roughness.
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: Restor Dent Endod Año: 2020 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: Restor Dent Endod Año: 2020 Tipo del documento: Article