Using collision-induced dissociation to constrain sensitivity of ammonia chemical ionization mass spectrometry ( N H 4 + CIMS) to oxygenated volatile organic compounds.
Zaytsev, Alexander; Breitenlechner, Martin; Koss, Abigail R; Lim, Christopher Y; Rowe, James C; Kroll, Jesse H; Keutsch, Frank N.
Afiliación
  • Zaytsev A; John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA.
  • Breitenlechner M; John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA.
  • Koss AR; Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
  • Lim CY; Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
  • Rowe JC; Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
  • Kroll JH; Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
  • Keutsch FN; John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA.
Atmos Meas Tech ; 12(3): 1861-1870, 2019.
Article en En | MEDLINE | ID: mdl-32215111
Chemical ionization mass spectrometry (CIMS) instruments routinely detect hundreds of oxidized organic compounds in the atmosphere. A major limitation of these instruments is the uncertainty in their sensitivity to many of the detected ions. We describe the development of a new high-resolution time-of-flight chemical ionization mass spectrometer that operates in one of two ionization modes: using either ammonium ion ligand-switching reactions such as for N H 4 + CIMS or proton transfer reactions such as for protontransfer-reaction mass spectrometer (PTR-MS). Switching between the modes can be done within 2min. The N H 4 + CIMS mode of the new instrument has sensitivities of up to 67 000 dcps ppbv-1 (duty-cycle-corrected ion counts per second per part per billion by volume) and detection limits between 1 and 60 pptv at 2σ for a 1 s integration time for numerous oxygenated volatile organic compounds. We present a mass spectrometric voltage scanning procedure based on collision-induced dissociation that allows us to determine the stability of ammonium-organic ions detected by the N H 4 + CIMS instrument. Using this procedure, we can effectively constrain the sensitivity of the ammonia chemical ionization mass spectrometer to a wide range of detected oxidized volatile organic compounds for which no calibration standards exist. We demonstrate the application of this procedure by quantifying the composition of secondary organic aerosols in a series of laboratory experiments.