Your browser doesn't support javascript.
loading
The design of a line velocity interferometer for any reflector for inertial confinement experiments on the Z-machine.
Datte, P; Baker, J; Bliss, D; Butler, N; Celliers, P; Cohen, S; Crosley, M; Edwards, J; Erskine, D; Fratanduono, D; Frieders, G; Galbraith, J; Hess, M; Johnson, D; Jones, M; LeChien, K; Lusk, J; Myers, C; McCarville, T; McDonald, R; Natoni, G; Olson, M; Raman, K; Robertson, G; Shelton, R; Shores, J; Speas, S; Spencer, D; de Dios, E Vergel; Wong, N.
Afiliación
  • Datte P; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Baker J; Sandia National Laboratory, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Bliss D; Sandia National Laboratory, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Butler N; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Celliers P; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Cohen S; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Crosley M; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Edwards J; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Erskine D; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Fratanduono D; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Frieders G; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Galbraith J; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Hess M; Sandia National Laboratory, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Johnson D; Sandia National Laboratory, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Jones M; Sandia National Laboratory, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • LeChien K; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Lusk J; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Myers C; Sandia National Laboratory, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • McCarville T; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • McDonald R; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Natoni G; Sandia National Laboratory, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Olson M; Sandia National Laboratory, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Raman K; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Robertson G; Sandia National Laboratory, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Shelton R; Sandia National Laboratory, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Shores J; Sandia National Laboratory, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Speas S; Sandia National Laboratory, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Spencer D; Sandia National Laboratory, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • de Dios EV; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
  • Wong N; Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA.
Rev Sci Instrum ; 91(4): 043508, 2020 Apr 01.
Article en En | MEDLINE | ID: mdl-32357683
ABSTRACT
A line VISAR (Velocity Interferometer System for Any Reflector) has been designed and commissioned at the Sandia National Laboratory's Z-machine. The instrument consists of an F/2 collection system, beam transport, and an interferometer table that contains two Mach-Zehnder type interferometers and an eight channel Gated Optical Imaging (GOI) system. The VISAR probe laser operates at the 532 nm wavelength, and the GOI bandpass is 540-600 nm. The output of each interferometer is passed to an optical streak camera with four selectable sweep speeds. The system is designed with three interchangeable optics modules to select a full field of view of 1 mm, 2 mm, or 4 mm. The optical beam transport system connects the target image plane to the interferometers and the gated optical imagers. The target is integrated into a sacrificial final optics assembly that is integral to the transport beamline.

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2020 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2020 Tipo del documento: Article País de afiliación: Estados Unidos