Your browser doesn't support javascript.
loading
Separation of enantiomers of chiral basic drugs with amylose- and cellulose- phenylcarbamate-based chiral columns in acetonitrile and aqueous-acetonitrile in high-performance liquid chromatography with a focus on substituent electron-donor and electron-acceptor effects.
Matarashvili, Iza; Chelidze, Aluda; Dolidze, Gizo; Kobidze, Giorgi; Zaqashvili, Nino; Dadianidze, Alexandre; Bacskay, Ivett; Felinger, Attila; Farkas, Tivadar; Chankvetadze, Bezhan.
Afiliación
  • Matarashvili I; Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences, Tbilisi State University, Chavchavadze Ave 3, 0179 Tbilisi, Georgia.
  • Chelidze A; Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences, Tbilisi State University, Chavchavadze Ave 3, 0179 Tbilisi, Georgia.
  • Dolidze G; Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences, Tbilisi State University, Chavchavadze Ave 3, 0179 Tbilisi, Georgia.
  • Kobidze G; Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences, Tbilisi State University, Chavchavadze Ave 3, 0179 Tbilisi, Georgia.
  • Zaqashvili N; Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences, Tbilisi State University, Chavchavadze Ave 3, 0179 Tbilisi, Georgia.
  • Dadianidze A; Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences, Tbilisi State University, Chavchavadze Ave 3, 0179 Tbilisi, Georgia.
  • Bacskay I; MTA-PTE Molecular Interactions in Separation Science Research Group, Ifjúság útja 6, H-7624 Pécs, Hungary.
  • Felinger A; MTA-PTE Molecular Interactions in Separation Science Research Group, Ifjúság útja 6, H-7624 Pécs, Hungary; Department of Analytical and Environmental Chemistry and Szentágothai Research Center, University of Pécs, Ifúság útja 6, Pécs H-7624, Hungary; Institute of Bioanalysis, Medical School, Univers
  • Farkas T; Phenomenex Inc., 411 Madrid Ave., Torrance 90501, CA, USA.
  • Chankvetadze B; Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences, Tbilisi State University, Chavchavadze Ave 3, 0179 Tbilisi, Georgia. Electronic address: jpba_bezhan@yahoo.com.
J Chromatogr A ; 1624: 461218, 2020 Aug 02.
Article en En | MEDLINE | ID: mdl-32540066
ABSTRACT
In this study, amylose- and cellulose-phenylcarbamate-based chiral columns with different chiral-selector (CS) chemistries were compared to each other for the separation of enantiomers of basic chiral analytes in acetonitrile and aqueous-acetonitrile mobile phases in HPLC. For two chemistries the amylose-based columns with coated and immobilized CSs were also compared. The comparison of CSs containing only electron-donating or electron-withdrawing substituents with those containing both electron-donating and electron-withdrawing substituents showed opposite results for the studied set of chiral analytes in the case of amylose and cellulose derivatives. Along with the chemistry of CS the focus was on the behavior of polysaccharide phenylcarbamates in acetonitrile versus aqueous acetonitrile as eluents. In agreement with earlier results, it was found that in contrast to the commonly accepted view, polysaccharide phenylcarbamates do not behave as typical reversed-phase materials for basic analytes either. In the range of water content in the mobile phase of up to 20-30% v/v the behavior of these CSs is similar to hydrophilic interaction liquid chromatography (HILIC)-type adsorbents. This means that with increasing water content in the mobile phase up to 20-30% v/v, the retention of analytes mostly decreases. The important finding of this study is that the separation efficiency improves for most analytes when switching from pure acetonitrile to aqueous acetonitrile. Therefore, in spite of reduced retention, the separation of enantiomers improves and thus, the HILIC-range of mobile phase composition, offering shorter analysis time and better peak resolution, is advantageous over pure polar-organic solvent mode. Interesting examples of enantiomer elution order (EEO) reversal were observed for some analytes based on the content of water in the mobile phase on Lux Cellulose-1 and Lux Amylose-2 columns.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Preparaciones Farmacéuticas / Celulosa / Cromatografía Líquida de Alta Presión / Fenilcarbamatos / Amilosa Idioma: En Revista: J Chromatogr A Año: 2020 Tipo del documento: Article País de afiliación: Georgia

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Preparaciones Farmacéuticas / Celulosa / Cromatografía Líquida de Alta Presión / Fenilcarbamatos / Amilosa Idioma: En Revista: J Chromatogr A Año: 2020 Tipo del documento: Article País de afiliación: Georgia