Your browser doesn't support javascript.
loading
Adaptive Pixel Mass Recalibration for Mass Spectrometry Imaging Based on Locally Endogenous Biological Signals.
La Rocca, Raphaël; Kune, Christopher; Tiquet, Mathieu; Stuart, Lachlan; Eppe, Gauthier; Alexandrov, Theodore; De Pauw, Edwin; Quinton, Loïc.
Afiliación
  • La Rocca R; Mass Spectrometry Laboratory, MolSys Research Unit, Department of Chemistry, University of Liège, Allée du Six Août, 11, Quartier Agora, Liège 4000, Belgium.
  • Kune C; Mass Spectrometry Laboratory, MolSys Research Unit, Department of Chemistry, University of Liège, Allée du Six Août, 11, Quartier Agora, Liège 4000, Belgium.
  • Tiquet M; Mass Spectrometry Laboratory, MolSys Research Unit, Department of Chemistry, University of Liège, Allée du Six Août, 11, Quartier Agora, Liège 4000, Belgium.
  • Stuart L; Structural and Computational Biology Unit, European Molecular Biology Laboratory, Heidelberg 69117, Germany.
  • Eppe G; Mass Spectrometry Laboratory, MolSys Research Unit, Department of Chemistry, University of Liège, Allée du Six Août, 11, Quartier Agora, Liège 4000, Belgium.
  • Alexandrov T; Structural and Computational Biology Unit, European Molecular Biology Laboratory, Heidelberg 69117, Germany.
  • De Pauw E; Skaggs School of Pharmacy and Pharmaceutical Sciences, University of California, San Diego, La Jolla 92093-0657, California, United States.
  • Quinton L; Mass Spectrometry Laboratory, MolSys Research Unit, Department of Chemistry, University of Liège, Allée du Six Août, 11, Quartier Agora, Liège 4000, Belgium.
Anal Chem ; 93(8): 4066-4074, 2021 03 02.
Article en En | MEDLINE | ID: mdl-33583182
ABSTRACT
Mass spectrometry imaging (MSI) is a powerful and convenient method for revealing the spatial chemical composition of different biological samples. Molecular annotation of the detected signals is only possible if a high mass accuracy is maintained over the entire image and the m/z range. However, the change in the number of ions from pixel-to-pixel of the biological samples could lead to small fluctuations in the detected m/z-values, called mass shift. The use of internal calibration is known to offer the best solution to avoid, or at least to reduce, mass shifts. Their "a priori" selection for a global MSI acquisition is prone to false positive detection and therefore to poor recalibration. To fill this gap, this work describes an algorithm that recalibrates each spectrum individually by estimating its mass shift with the help of a list of pixel-specific internal calibrating ions, automatically generated in a data-adaptive manner (https//github.com/LaRoccaRaphael/MSI_recalibration). Through a practical example, we applied the methodology to a zebrafish whole-body section acquired at a high mass resolution to demonstrate the impact of mass shift on data analysis and the capability of our algorithm to recalibrate MSI data. In addition, we illustrate the broad applicability of the method by recalibrating 31 different public MSI data sets from METASPACE from various samples and types of MSI and show that our recalibration significantly increases the numbers of METASPACE annotations (gaining from 20 up to 400 additional annotations), particularly the high-confidence annotations with a low false discovery rate.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Pez Cebra / Técnicas Histológicas Límite: Animals Idioma: En Revista: Anal Chem Año: 2021 Tipo del documento: Article País de afiliación: Bélgica

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Pez Cebra / Técnicas Histológicas Límite: Animals Idioma: En Revista: Anal Chem Año: 2021 Tipo del documento: Article País de afiliación: Bélgica