Your browser doesn't support javascript.
loading
Effects of air purification of indoor PM2.5 on the cardiorespiratory biomarkers in young healthy adults.
Wang, Yuxin; Zhao, Yan; Xue, Lijun; Wu, Shaowei; Wang, Bin; Li, Guoxing; Huang, Jing; Guo, Xinbiao.
Afiliación
  • Wang Y; Department of Occupational and Environmental Health Science, Peking University School of Public Health, Beijing, China.
  • Zhao Y; Department of Occupational and Environmental Health Science, Peking University School of Public Health, Beijing, China.
  • Xue L; Department of Occupational and Environmental Health Science, Peking University School of Public Health, Beijing, China.
  • Wu S; Department of Occupational and Environmental Health School of Public Health, School of Public Health, Xi'an Jiaotong University Health Science Center, Xi'an, China.
  • Wang B; Department of Occupational and Environmental Health Science, Peking University School of Public Health, Beijing, China.
  • Li G; Department of Occupational and Environmental Health Science, Peking University School of Public Health, Beijing, China.
  • Huang J; Department of Occupational and Environmental Health Science, Peking University School of Public Health, Beijing, China.
  • Guo X; Department of Occupational and Environmental Health Science, Peking University School of Public Health, Beijing, China.
Indoor Air ; 31(4): 1125-1133, 2021 07.
Article en En | MEDLINE | ID: mdl-33682970
ABSTRACT
Ambient fine particulate matter (PM2.5 ), as one of the predominant air pollutants, has achieved effective control in recent years in China. Whether the use of indoor air purifiers is still necessary needs further exploration. A randomized crossover trial was conducted in 54 healthy students in Beijing, China. Participants were randomized assigned to the use of real or sham high-efficiency particulate air filter (HEPA) for a week and changed the status after a washout period. Health measurements of cardiorespiratory biomarkers were performed at the end of each period. Linear mixed-effects models were used to evaluate the association between PM2.5 exposure and cardiorespiratory biomarkers. Compared with sham air purification, average diastolic blood pressure (DBP), fractional exhaled nitric oxide (FeNO), and 8-isoprostane (8-isoPGF2α) levels decreased significantly in the real purification. The effects of indoor air purification on lung function indicators including forced expiratory volume in one second (FEV1 ), peak expiratory flow (PEF), and forced expiratory flow between the 25th and 75th percentile of forced vital capacity (FEF25%-75% ) were also significant. Our findings showed a protective effect of indoor HEPA air purifiers on cardiorespiratory health of young healthy adults reflected by the decreased blood pressure, respiratory inflammation, and systematic oxidative stress and improved lung function.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Contaminación del Aire Interior / Contaminantes Atmosféricos / Contaminación del Aire / Filtros de Aire Tipo de estudio: Clinical_trials / Prognostic_studies Límite: Adult / Humans Idioma: En Revista: Indoor Air Asunto de la revista: SAUDE AMBIENTAL Año: 2021 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Contaminación del Aire Interior / Contaminantes Atmosféricos / Contaminación del Aire / Filtros de Aire Tipo de estudio: Clinical_trials / Prognostic_studies Límite: Adult / Humans Idioma: En Revista: Indoor Air Asunto de la revista: SAUDE AMBIENTAL Año: 2021 Tipo del documento: Article País de afiliación: China