Your browser doesn't support javascript.
loading
Evaluation of efficacy and safety of intraoral negative air pressure device in adults with obstructive sleep apnea in Taiwan.
Cheng, Ching-Yuan; Chen, Chia-Chi; Lo, Men-Tzung; Guilleminault, Christian; Lin, Chia-Mo.
Afiliación
  • Cheng CY; Sleep Center, Thoracic Medicine, Shin Kong Memorial Wu Ho-Su Hospital, Taipei, Taiwan.
  • Chen CC; Sleep Center, Thoracic Medicine, Shin Kong Memorial Wu Ho-Su Hospital, Taipei, Taiwan; Department of Biomedical Sciences & Engineering, National Central University, Taoyuan, Taiwan.
  • Lo MT; Department of Biomedical Sciences & Engineering, National Central University, Taoyuan, Taiwan.
  • Guilleminault C; Stanford University Sleep Medicine Division, Redwood City, CA, USA.
  • Lin CM; Sleep Center, Thoracic Medicine, Shin Kong Memorial Wu Ho-Su Hospital, Taipei, Taiwan; Graduate Institute of Biomedical and Pharmaceutical Science, Fu-Jen Catholic University, New Taipei City, Taiwan. Electronic address: aminus64@gmail.com.
Sleep Med ; 81: 163-168, 2021 05.
Article en En | MEDLINE | ID: mdl-33706052
ABSTRACT

OBJECTIVE:

Through this study, we aimed to evaluate the efficacy and safety of the intraoral negative air pressure device (iNAP) in patients with moderate to severe obstructive sleep apnea (OSA) in Taiwan.

DESIGN:

Crossover and evaluator-blind, self-control design.

SETTING:

Academic medical center. PATIENTS A total of 35 patients provided their consent to participate in this study; however, only 34 patients (30 men [87.5%] and four women [12.50%]) were eligible and randomized to the Clinical Cohort and Safety Cohort. The mean age of the 32 evaluable patients (PE cohort) was 47.4 ± 11.2 years, and their mean BMI was 26.5 ± 3.2 kg/m2. MEASUREMENTS AND

RESULTS:

The clinical response rate was 75% (24/32 patients) comparing the treatment polysomnography values to the baseline values. The mean (±standard deviation) baseline apnea-hypopnea index was 32.0 ± 11.3 events/h, which decreased significantly to 8.7 ± 9.4 events/h. Mo medical device-related adverse event or serious adverse event occurred during the study period.

CONCLUSIONS:

Compared with the previous oral pressure therapy device, the iNAP treated approximately three-fourths of the patients with OSA and had a superior comfort and safety profile. Thus, the iNAP device could be an alternative treatment solution for patients with moderate to severe OSA.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Apnea Obstructiva del Sueño Tipo de estudio: Clinical_trials / Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged País/Región como asunto: Asia Idioma: En Revista: Sleep Med Asunto de la revista: NEUROLOGIA / PSICOFISIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Taiwán

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Apnea Obstructiva del Sueño Tipo de estudio: Clinical_trials / Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged País/Región como asunto: Asia Idioma: En Revista: Sleep Med Asunto de la revista: NEUROLOGIA / PSICOFISIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Taiwán