Your browser doesn't support javascript.
loading
Graphene Coating Obtained in a Cold-Wall CVD Process on the Co-Cr Alloy (L-605) for Medical Applications.
Wasyluk, Lukasz; Boiko, Vitalii; Markowska, Marta; Hasiak, Mariusz; Saladino, Maria Luisa; Hreniak, Dariusz; Amati, Matteo; Gregoratti, Luca; Zeller, Patrick; Bialy, Dariusz; Arkowski, Jacek; Wawrzynska, Magdalena.
Afiliación
  • Wasyluk L; Division of Optical Spectroscopy, Institute of Low Temperature and Structure Research, Polish Academy of Sciences, Okólna 2, PL-50-422 Wroclaw, Poland.
  • Boiko V; Division of Optical Spectroscopy, Institute of Low Temperature and Structure Research, Polish Academy of Sciences, Okólna 2, PL-50-422 Wroclaw, Poland.
  • Markowska M; Carbonmed Spólka z ograniczona odpowiedzialnoscia, ul. Okólna 2, PL-50-422 Wroclaw, Poland.
  • Hasiak M; Institute of Physics of the National Academy of Science of Ukraine, Prospect Nauky 46, UA-03028 Kyiv, Ukraine.
  • Saladino ML; Division of Optical Spectroscopy, Institute of Low Temperature and Structure Research, Polish Academy of Sciences, Okólna 2, PL-50-422 Wroclaw, Poland.
  • Hreniak D; Carbonmed Spólka z ograniczona odpowiedzialnoscia, ul. Okólna 2, PL-50-422 Wroclaw, Poland.
  • Amati M; Department of Mechanics, Materials Science and Biomedical Engineering, Wroclaw University of Science and Technology, Smoluchowskiego 25, PL-50-370 Wroclaw, Poland.
  • Gregoratti L; Department of Biological, Chemical and Pharmaceutical Sciences and Technologies (STEBICEF) and INSTM UdR-Palermo, University of Palermo, Viale delle Scienze, Bld. 17, IT-90128 Palermo, Italy.
  • Zeller P; Division of Optical Spectroscopy, Institute of Low Temperature and Structure Research, Polish Academy of Sciences, Okólna 2, PL-50-422 Wroclaw, Poland.
  • Bialy D; Carbonmed Spólka z ograniczona odpowiedzialnoscia, ul. Okólna 2, PL-50-422 Wroclaw, Poland.
  • Arkowski J; Elettra-Sincrotrone Trieste S.C.p.A., SS14-km 163.5 in Area Science Park, IT-34149 Trieste, Italy.
  • Wawrzynska M; Elettra-Sincrotrone Trieste S.C.p.A., SS14-km 163.5 in Area Science Park, IT-34149 Trieste, Italy.
Int J Mol Sci ; 22(6)2021 Mar 13.
Article en En | MEDLINE | ID: mdl-33805752
ABSTRACT
Graphene coating on the cobalt-chromium alloy was optimized and successfully carried out by a cold-wall chemical vapor deposition (CW-CVD) method. A uniform layer of graphene for a large area of the Co-Cr alloy (discs of 10 mm diameter) was confirmed by Raman mapping coated area and analyzing specific G and 2D bands; in particular, the intensity ratio and the number of layers were calculated. The effect of the CW-CVD process on the microstructure and the morphology of the Co-Cr surface was investigated by scanning X-ray photoelectron microscope (SPEM), atomic force microscopy (AFM), scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). Nanoindentation and scratch tests were performed to determine mechanical properties of Co-Cr disks. The results of microbiological tests indicate that the studied Co-Cr alloys covered with a graphene layer did not show a pro-coagulant effect. The obtained results confirm the possibility of using the developed coating method in medical applications, in particular in the field of cardiovascular diseases.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Aleaciones de Cromo / Materiales Biocompatibles Revestidos / Grafito Límite: Animals / Humans Idioma: En Revista: Int J Mol Sci Año: 2021 Tipo del documento: Article País de afiliación: Polonia

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Aleaciones de Cromo / Materiales Biocompatibles Revestidos / Grafito Límite: Animals / Humans Idioma: En Revista: Int J Mol Sci Año: 2021 Tipo del documento: Article País de afiliación: Polonia