Comparison of multiple oncotype DX® from the same patient.
Breast J
; 27(11): 828-831, 2021 11.
Article
en En
| MEDLINE
| ID: mdl-34514676
ABSTRACT
For women with breast cancer in whom multiple Oncotype DX® Recurrence Scores (RS) are obtained, RS concordance utilizing current NCCN recommendations has not been evaluated. Patients with two or more RS were identified. RS were stratified by NCCN guidelines and compared for concordance. Twenty-four patients were evaluated. RS concordance varied by tumor type 100% in the same tumor, 91.7% in multiple ipsilateral tumors, 71.4% in contralateral tumors, and 66.7% in in-breast recurrent tumors. RS concordance for multiple assays in the same patient is not high enough to omit Oncotype DX® testing for each tumor.