Measurement Techniques for Leg Length Discrepancy in Total Hip Arthroplasty: A Systematic Review of Reliability and Validity.
Pettit, Matthew H; Kanavathy, Sathisvaran; McArthur, Nicholas; Weiss, Ori; Khanduja, Vikas.
Afiliación
  • Pettit MH; University of Cambridge, Cambridge, United Kingdom.
  • Kanavathy S; The Royal Melbourne Hospital, Victoria, Australia.
  • McArthur N; Young Adult Hip Service, Department of Trauma and Orthopaedics, Addenbrooke's - Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom.
  • Weiss O; Young Adult Hip Service, Department of Trauma and Orthopaedics, Addenbrooke's - Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom.
  • Khanduja V; Young Adult Hip Service, Department of Trauma and Orthopaedics, Addenbrooke's - Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom.
J Arthroplasty ; 37(12): 2507-2516.e11, 2022 12.
Article en En | MEDLINE | ID: mdl-35605764
BACKGROUND: Total hip arthroplasty (THA) carries a substantial litigative burden. THA may introduce leg length discrepancy (LLD), necessitating a valid and reliable technique for LLD measurement. This study investigates the reliability and validity of techniques quantitively measuring LLD in both pre- and post-THA. METHODS: Embase and MEDLINE databases were searched following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines for articles assessing either the validity or reliability of LLD measurement techniques. Data was pooled using random effects meta-analysis to derive reliability estimates. Study quality was assessed using the Brink and Louw checklist. RESULTS: Forty-two articles with 2059 participants were included. Thirty-three investigated reliability and 25 validity. Reliability displayed high heterogeneity. Poor to excellent intra-rater reliability was reported for antero-posterior pelvis radiographs, moderate to excellent for computed tomography scanograms, and good to excellent for clinical methods and teleradiography, and excellent for bi-planar radiography (BPR). Poor to excellent inter-rater reliability was reported for antero-posterior pelvis radiographs and clinical methods, moderate to excellent for teleradiography, good to excellent for computed tomography scanogram and excellent for BPR. The tape measure method is a valid clinical measure of LLD whilst markerless motion analysis and the block method are not. Imaging techniques are appropriately cross-validated with the exception of BPR. CONCLUSION: The reported intra- and inter-rater reliability for most measurement techniques vary widely. The tape measure method is a valid clinical measurement of LLD. Imaging techniques have been appropriately cross-validated, with the exception of BPR, although they lack validation against a common reference technique.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Cadera Tipo de estudio: Diagnostic_studies / Guideline / Systematic_reviews Límite: Humans Idioma: En Revista: J Arthroplasty Asunto de la revista: ORTOPEDIA Año: 2022 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Cadera Tipo de estudio: Diagnostic_studies / Guideline / Systematic_reviews Límite: Humans Idioma: En Revista: J Arthroplasty Asunto de la revista: ORTOPEDIA Año: 2022 Tipo del documento: Article País de afiliación: Reino Unido