Your browser doesn't support javascript.
loading
[Simultaneous determination of 11 neurotransmitters in brain microdialysis samples from rats by UPLC-MS/MS].
Pan, Ling-Yun; Wang, Yu; Liu, Xin-Hua; Jia, Yi-Qun.
Afiliación
  • Pan LY; Experiment Center for Science and Technology, Shanghai University of Traditional Chinese Medicine Shanghai 201203, China.
  • Wang Y; Experiment Center for Science and Technology, Shanghai University of Traditional Chinese Medicine Shanghai 201203, China.
  • Liu XH; Experiment Center for Science and Technology, Shanghai University of Traditional Chinese Medicine Shanghai 201203, China.
  • Jia YQ; Experiment Center for Science and Technology, Shanghai University of Traditional Chinese Medicine Shanghai 201203, China.
Zhongguo Zhong Yao Za Zhi ; 47(12): 3242-3250, 2022 Jun.
Article en Zh | MEDLINE | ID: mdl-35851117
ABSTRACT
This study established a method for simultaneous determination of 11 neurotransmitters, such as acetylcholine, glutamic acid, glycine, and norepinephrine from rat brain microdialysis samples using UPLC-MS/MS. A total of 20 µL of rat brain dialysate was diluted with 60 µL of acetonitrile-water(4∶1) and centrifuged for 10 min at 10 000 r·min~(-1),and 5 µL was injected into UPLC-MS/MS system for assay. Chromatographic separation was performed on a Waters ACQUITY BEH amide column(2.1 mm×100 mm, 1.7 µm) with gradient elution using acetonitrile/0.2% formic acid-water as mobile phases with a flow rate of 0.35 mL·min~(-1) and column temperature of 35 ℃. The eluate was detected by multiple-reaction monitoring(MRM) scanning with an electrospray ionization source operating in the positive ionization mode with an analysis duration of 3.5 min. The relationship between the recovery rate of 11 neurotransmitters and the perfusion rate or the concentration of neurotransmitters was investigated. Furthermore, the effects of puerarin alone or combined with borneol on the content of 11 neurotransmitters in the striatum of rats were investigated. The results showed the calibration curves displayed good linear regression with coefficients all greater than 0.99 and the lower limit of quantification(LLOQ) less than 12.5 nmol·L~(-1) for each analyte. The within-run and between-run precision(RSD) of the 11 neurotransmitters at low, medium, and high levels was less than 9.3%, and the relative error of the accuracy ranged from-8.4% to 9.5%. The stability, recovery, and matrix effects were in line with the biological sample analysis requirements. As revealed by experimental results, the levels of most neurotransmitters in the brain striatum changed significantly after rats were treated with puerarin as compared with the conditions in the blank group. Except for dopamine and norepinephrine, the degree of changes of other neurotransmitters in the combination group(borneol and puerarin) was less than that of the puerarin group. The established UPLC-MS/MS method could be applied to the quantitative determination of 11 neurotransmitters in microdialysis samples, providing an efficient and useful tool to study neurotransmitter changes in animal models of health and diseases.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Neurotransmisores / Espectrometría de Masas en Tándem Tipo de estudio: Prognostic_studies Límite: Animals Idioma: Zh Revista: Zhongguo Zhong Yao Za Zhi Asunto de la revista: FARMACOLOGIA / TERAPIAS COMPLEMENTARES Año: 2022 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Neurotransmisores / Espectrometría de Masas en Tándem Tipo de estudio: Prognostic_studies Límite: Animals Idioma: Zh Revista: Zhongguo Zhong Yao Za Zhi Asunto de la revista: FARMACOLOGIA / TERAPIAS COMPLEMENTARES Año: 2022 Tipo del documento: Article País de afiliación: China