Your browser doesn't support javascript.
loading
Efficacy and safety of the extraction of cardiostimulation leads using a mechanical dissection tool. A single center experience.
Villegas, Elkin González; Juárez Del Río, José Ignacio; Carmona, José Carlos Romero; Valdíris, Ulises Ramírez; Peinado, Ángel Aroca; Peinado, Rafael Peinado.
Afiliación
  • Villegas EG; Cardiac Surgery University Hospital La Paz, Madrid, Spain.
  • Juárez Del Río JI; Cardiac Surgery University Hospital La Paz, Madrid, Spain.
  • Carmona JCR; Cardiac Surgery University Hospital La Paz, Madrid, Spain.
  • Valdíris UR; Cardiac Surgery University Hospital La Paz, Madrid, Spain.
  • Peinado ÁA; Cardiac Surgery University Hospital La Paz, Madrid, Spain.
  • Peinado RP; Electrophysiology Department University Hospital La Paz, Madrid, Spain.
Pacing Clin Electrophysiol ; 46(3): 217-225, 2023 03.
Article en En | MEDLINE | ID: mdl-36401870
BACKGROUND: The percutaneous extraction of endovascular cardiostimulation and defibrillation leads is the most frequent technique nowadays. The tools used today must guarantee the success of the procedure, with the minimum of complications. Our objective was to analyze the safety and efficacy of lead extraction using the Evolution mechanical dissection tool (Cook Medical, USA). METHODS: A retrospective study was carried out in a total of 826 consecutive patients from October 2009 to December 2018 who underwent the procedure with the Evolution mechanical dissection tool. Preoperative study included complete blood tests, echocardiogram, and chest X-ray. The procedures were performed in the operating room, under general anesthesia and echocardiographic control. RESULTS: A total of 1227 leads were extracted with a mean chronicity of 10.3 ± 5.1 years. Clinical success (CS) rate was 99.7%. A total of 16 (1.9%) complications occurred, 2 (0.24%) were major complications and 14 (1.7%) were minor complications. There was no operative mortality. There was no statistically significant relationship between implant chamber and complete efficacy. The complete extraction was achieved in all left ventricular leads, in 762 of 774 (98.45%) of right ventricular lead removal, and in 330 of 334 (98.8%) of right atrial leads (p = .31). CONCLUSION: In our experience, percutaneous extraction of intravenous leads via the use of the Evolution tool (Cook Medical, USA), is a very effective and safe technique that offers low morbidity and mortality.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Marcapaso Artificial / Desfibriladores Implantables Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: Pacing Clin Electrophysiol Año: 2023 Tipo del documento: Article País de afiliación: España

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Marcapaso Artificial / Desfibriladores Implantables Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: Pacing Clin Electrophysiol Año: 2023 Tipo del documento: Article País de afiliación: España