Evaluation of postcontrast images of intracranial tumors at 7T and 3T MRI: An intra-individual comparison study.
Cheng, Kun; Duan, Qi; Hu, Jianxing; Li, Chenxi; Ma, Xiaoxiao; Bian, Xiangbing; Duan, Caohui; Xiong, Yongqin; Lin, Jiaji; Lu, Haoxuan; Deng, Linlin; Li, Ze; Wei, Mengting; Lyu, Jinhao; Chen, Ling; Lou, Xin.
Afiliación
  • Cheng K; Department of Radiology, Chinese PLA General Hospital, Beijing, China.
  • Duan Q; School of Medical Imaging, Guizhou Medical University, Guiyang, China.
  • Hu J; Medical School of Chinese PLA, Beijing, China.
  • Li C; Department of Radiology, Chinese PLA General Hospital, Beijing, China.
  • Ma X; Medical School of Chinese PLA, Beijing, China.
  • Bian X; Department of Radiology, Chinese PLA General Hospital, Beijing, China.
  • Duan C; Department of Radiology, Chinese PLA General Hospital, Beijing, China.
  • Xiong Y; Department of Radiology, Chinese PLA General Hospital, Beijing, China.
  • Lin J; Department of Radiology, Chinese PLA General Hospital, Beijing, China.
  • Lu H; Department of Radiology, Chinese PLA General Hospital, Beijing, China.
  • Deng L; Medical School of Chinese PLA, Beijing, China.
  • Li Z; School of Medical Imaging, Guizhou Medical University, Guiyang, China.
  • Wei M; Department of Neurosurgery, Chinese PLA General Hospital, Beijing, China.
  • Lyu J; School of Medical Imaging, Guizhou Medical University, Guiyang, China.
  • Chen L; Department of Radiology, Chinese PLA General Hospital, Beijing, China.
  • Lou X; Department of Neurosurgery, Chinese PLA General Hospital, Beijing, China.
CNS Neurosci Ther ; 29(2): 559-565, 2023 02.
Article en En | MEDLINE | ID: mdl-36468424
ABSTRACT

AIM:

This study aimed to evaluate the diagnostic value of ultrahigh-field magnetic resonance imaging (MRI) for brain tumors in clinical practice.

METHODS:

Thirty patients with brain tumors underwent 7- and 3-T MRI. The performance and diagnostic confidence of 7- and 3-T MRI in the visualization of tumor details such as internal structure and feeding artery were evaluated by radiologists. Contrast-enhanced region performance and tumor detail diagnostic confidence score (DCS) were calculated and compared between 7 and 3T using Wilcoxon rank sum test.

RESULTS:

In 19 with obvious enhancement and 11 cases without obvious enhancement, 7- and 3-T MRI showed similar performance. The tumors' internal structure and feeding artery were more clearly depicted by 7-T MRI (62.2% and 54.4%, respectively) than by 3-T MRI (2.2% and 6.7%, respectively). Furthermore, the mean DCSs of both internal structure and feeding artery were higher at 7T than at 3T (internal structure 16.29 ± 9.67 vs. -5.79 ± 4.12, p = 0.028; feeding artery 21.96 ± 6.93 vs. 4.46 ± 7.07, p = 0.028). The DCS was more significantly improved in the senior radiologist group.

CONCLUSION:

Better visualization of brain tumor details and higher tumor detail diagnostic confidence can be obtained with 7-T MRI.