SiOC Screens with Aligned and Adjustable Pore Structure for Screen Channel Liquid Acquisition Device.
da Rosa Braun, Pedro Henrique; Shukla, Prithvi; Rezwan, Kurosch; Dreyer, Michael; Wilhelm, Michaela.
Afiliación
  • da Rosa Braun PH; Advanced Ceramics, University of Bremen, Am Biologischen Garten 2, IW3, 28359 Bremen, Germany.
  • Shukla P; Center of Applied Space Technology and Microgravity (ZARM), Department of Fluid Mechanics, Faculty of Production Engineering-Mechanical Engineering and Process Engineering, University of Bremen, Am Fallturm 2, 28359 Bremen, Germany.
  • Rezwan K; Advanced Ceramics, University of Bremen, Am Biologischen Garten 2, IW3, 28359 Bremen, Germany.
  • Dreyer M; MAPEX-Center for Materials and Processes, University of Bremen, Am Fallturm 1, 28359 Bremen, Germany.
  • Wilhelm M; Center of Applied Space Technology and Microgravity (ZARM), Department of Fluid Mechanics, Faculty of Production Engineering-Mechanical Engineering and Process Engineering, University of Bremen, Am Fallturm 2, 28359 Bremen, Germany.
Materials (Basel) ; 16(3)2023 Jan 25.
Article en En | MEDLINE | ID: mdl-36770070
The development of porous ceramic screens with high chemical stability, low density, and thermal conductivity can lead to promising screen channel liquid acquisition devices (SC-LADs) for propellant management under microgravity conditions in the future. Therefore, SiOC screens with aligned pores were fabricated via freeze-casting and applied as a SC-LAD. The pore window sizes and open porosity varied from 6 µm to 43 µm and 65% or 79%, depending on the freezing temperature or the solid loading, respectively. The pore window size distributions and bubble point tests indicate crack-free screens. On the one hand, SC-LADs with an open porosity of 79% removed gas-free liquid up to a volumetric flow rate of 4 mL s-1. On the other hand, SC-LADs with an open porosity of 65% were limited to 2 mL s-1 as the pressure drop across these screens was relatively higher. SC-LADs with the same open porosity but smaller pore window sizes showed a higher pressure drop across the screen and bubble ingestion at higher values of effective screen area when increasing the applied removal volumetric flow rate. The removed liquid from the SC-LADs was particle-free, thus representing a potential for applications in a harsh chemical environment or broad-range temperatures.