Your browser doesn't support javascript.
loading
Evaluation of the One-Hour ¹³C-Propionate Breath Test in 49 Patients from a Single Center in Japan to Detect Vitamin B12 Deficiency.
Sasaki, Yosuke; Sato, Takahiro; Maeda, Tadashi; Komatsu, Fumiya; Kawagoe, Naoyuki; Imai, Tsunehiko; Shigeta, Tomoyuki; Kashima, Naoyasu; Urita, Yoshihisa.
Afiliación
  • Sasaki Y; Department of General Medicine and Emergency Care, Toho University School of Medicine, Tokyo, Japan.
  • Sato T; Department of General Medicine and Emergency Care, Toho University School of Medicine, Tokyo, Japan.
  • Maeda T; Department of General Medicine and Emergency Care, Toho University School of Medicine, Tokyo, Japan.
  • Komatsu F; Department of General Medicine and Emergency Care, Toho University School of Medicine, Tokyo, Japan.
  • Kawagoe N; Department of General Medicine and Emergency Care, Toho University School of Medicine, Tokyo, Japan.
  • Imai T; Department of General Medicine and Emergency Care, Toho University School of Medicine, Tokyo, Japan.
  • Shigeta T; Department of General Medicine and Emergency Care, Toho University School of Medicine, Tokyo, Japan.
  • Kashima N; Department of General Medicine and Emergency Care, Toho University School of Medicine, Tokyo, Japan.
  • Urita Y; Department of General Medicine and Emergency Care, Toho University School of Medicine, Tokyo, Japan.
Med Sci Monit ; 29: e940238, 2023 May 08.
Article en En | MEDLINE | ID: mdl-37150974
BACKGROUND Given the unavailability of reliable biomarkers for vitamin B12 (VB12) deficiency in clinical settings, the usefulness of the ¹³C-propionate breath test (PBT), utilizing VB12 as a coenzyme of methylmalonyl-CoA in propionate metabolism, as a diagnostic modality for VB12 deficiency has been studied. However, a collection time of 2 h reduces its convenience. Hence, we evaluated the effectiveness of 1-h PBT for detecting VB12 deficiency in 49 patients with suspected VB12 deficiency. MATERIAL AND METHODS We collected 100-200 mL breath gas every 10 min until 1 h after the administration of 1 g of ¹³C-propionate from 49 patients (31 men, 18 women; median age, 70 years) with clinically suspected VB12 deficiency and calculated the ¹³CO2 recovered in the breath per hour as the recovery rate (RR [%dose/h]) from ¹³CO2/¹²CO2 using infrared isotope spectrometry. We compared the RRs between groups: (1) with serum VB12 levels ≥145 pg/mL and <145 pg/mL, (2) with mean corpuscular volume ≤100 fL and >100 fL, and 3) pre- and post-VB12 supplementation. RESULTS The RRs peaked within 30 min. The RRs at 20 min (RR20) and 30 min (RR30) were significantly lower in macrocytotic patients (41.28 vs 50.07, p=0.026 and 37.82 vs 43.93, P=0.003). The RR30 was higher in the supplemented patients (41.93 vs 32.84, P=0.024). There was no significant difference in RRs between the patients with normal and low serum VB12 levels. CONCLUSIONS The 1-h PBT can be a diagnostic modality for VB12 deficiency because 1 h is a sufficient collection time.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Propionatos / Deficiencia de Vitamina B 12 Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Aged / Female / Humans / Male País/Región como asunto: Asia Idioma: En Revista: Med Sci Monit Asunto de la revista: MEDICINA Año: 2023 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Propionatos / Deficiencia de Vitamina B 12 Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Aged / Female / Humans / Male País/Región como asunto: Asia Idioma: En Revista: Med Sci Monit Asunto de la revista: MEDICINA Año: 2023 Tipo del documento: Article País de afiliación: Japón