Your browser doesn't support javascript.
loading
A novel biplanar positioning technique to guide iliosacral screw insertion: a retrospective study.
Zhao, Yangyang; Cui, Pengju; Xiong, Zhenggang; Zheng, Jiachun; Xing, Deguo.
Afiliación
  • Zhao Y; Trauma Orthopedics, The Second Hospital of Shandong University, 247 Beiyuan Street, Tianqiao District, Jinan City, 250031, China.
  • Cui P; Trauma Orthopedics, The Second Hospital of Shandong University, 247 Beiyuan Street, Tianqiao District, Jinan City, 250031, China.
  • Xiong Z; Trauma Orthopedics, The Second Hospital of Shandong University, 247 Beiyuan Street, Tianqiao District, Jinan City, 250031, China.
  • Zheng J; Trauma Orthopedics, The Second Hospital of Shandong University, 247 Beiyuan Street, Tianqiao District, Jinan City, 250031, China.
  • Xing D; Trauma Orthopedics, The Second Hospital of Shandong University, 247 Beiyuan Street, Tianqiao District, Jinan City, 250031, China. sdeyzyy@126.com.
BMC Musculoskelet Disord ; 24(1): 374, 2023 May 11.
Article en En | MEDLINE | ID: mdl-37170257
PURPOSE: To evaluate the safety and benefits of the biplanar position technique on operative time, radiation exposure, and screw placement accuracy. METHODS: In this study, we retrospectively evaluated the records of 64 patients with pelvic fractures (Tile B and C) between October 2020 and September 2021. According to the surgical methods selected by the patients, the patients were divided into a biplanar positioning technique group (biplanar group), a Ti-robot navigation group (Ti-robot group), and a traditional fluoroscopy-guided technique group (traditional group). Length of operation, blood loss, intra-operative radiation exposure fracture reduction, and the quality of screw positioning were compared among the three groups. RESULTS: One hundred three screws were implanted in 64 patients (biplanar group 22, Ti-robot group 21, traditional group 21). The average operation time was significantly less in the biplanar group (26.32 ± 6.32 min) than in the traditional group (79.24 ± 11.31 min), but significantly more than in the Ti-robot group (15.81 ± 3.9 min). The radiation exposure was similar in the biplanar group (740.53 ± 185.91 cGy/cm2) and Ti-robot group (678.44 ± 127.16 cGy/cm2), both of which were significantly more than in the traditional group (2034.58 ± 494.54 cGy/cm2). The intra-operative blooding loss was similar in the biplanar group (12.76 ± 3.77 mL) and the Ti-robot group (11.92 ± 4.67 mL), both of which were significantly less than in the traditional group (29.7 ± 8.01 mL). The Screw perforation was slightly lower in the biplanar group (94.1%) than in the Ti-robot group (97.2%) but was significantly higher than in the traditional group (75.7%). CONCLUSIONS: The biplanar positioning technique is as accurate and safe as computer-navigated systems for percutaneous iliosacral screw insertion, associated with shorter surgical time, lower intra-operative radiation exposure, and more accuracy compared to traditional fluoroscopy.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Huesos Pélvicos / Fracturas Óseas Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: BMC Musculoskelet Disord Asunto de la revista: FISIOLOGIA / ORTOPEDIA Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Huesos Pélvicos / Fracturas Óseas Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: BMC Musculoskelet Disord Asunto de la revista: FISIOLOGIA / ORTOPEDIA Año: 2023 Tipo del documento: Article País de afiliación: China