Your browser doesn't support javascript.
loading
Hostile Hemodynamics in Distal Stent Graft-Induced New Entry Prior to Aortic Rupture: A Comparison of Transient versus Steady-State CFD Simulations.
Osswald, Anja; Tsagakis, Konstantinos; Demircioglu, Ender; Weymann, Alexander; Zubarevich, Alina; Ruhparwar, Arjang; Karmonik, Christof.
Afiliación
  • Osswald A; Department of Thoracic and Cardiovascular Surgery, West-German Heart and Vascular Center Essen, University Duisburg-Essen, Essen, Germany.
  • Tsagakis K; Department of Thoracic and Cardiovascular Surgery, West-German Heart and Vascular Center Essen, University Duisburg-Essen, Essen, Germany.
  • Demircioglu E; Department of Thoracic and Cardiovascular Surgery, West-German Heart and Vascular Center Essen, University Duisburg-Essen, Essen, Germany.
  • Weymann A; Department of Thoracic and Cardiovascular Surgery, West-German Heart and Vascular Center Essen, University Duisburg-Essen, Essen, Germany.
  • Zubarevich A; Department of Thoracic and Cardiovascular Surgery, West-German Heart and Vascular Center Essen, University Duisburg-Essen, Essen, Germany.
  • Ruhparwar A; Department of Thoracic and Cardiovascular Surgery, West-German Heart and Vascular Center Essen, University Duisburg-Essen, Essen, Germany.
  • Karmonik C; MRI Core, Translational Imaging Center, Houston Methodist Research Institute, Houston, Texas, United States.
Thorac Cardiovasc Surg ; 72(2): 134-141, 2024 Mar.
Article en En | MEDLINE | ID: mdl-37506731
ABSTRACT

BACKGROUND:

Computational fluid dynamics (CFD) simulations model blood flow in aortic pathologies. The aim of our study was to understand the local hemodynamic environment at the site of rupture in distal stent graft-induced new entry (dSINE) after frozen elephant trunk with a clinically time efficient steady-flow simulation versus transient simulations.

METHODS:

Steady-state simulations were performed for dSINE, prior and after its development and prior to aortic rupture. To account for potential turbulences due geometric changes at the dSINE location, Reynolds-averaged Navier-Stokes equations with the realizable k-ε model for turbulences were applied. Transient simulations were performed for comparison. Hemodynamic parameters were assessed at various locations of the aorta.

RESULTS:

Post-dSINE, jet-like flow due to luminal narrowing was observed which increased prior to rupture and resulted in focal neighbored regions of high and low wall shear stress (WSS). Prior to rupture, aortic diameter at the rupture site increased lowering WSS at the entire aortic circumference. Concurrently, WSS and turbulence increased locally above the entry tear at the inner aortic curvature. Turbulent kinetic energy and WSS elevation in the downstream aorta demonstrated enhanced stress on the native aorta. Results of steady-state simulations were in good qualitative agreement with transient simulations.

CONCLUSION:

Steady-flow CFD simulations feasible at clinical time scales prior to aortic rupture reveal a hostile hemodynamic environment at the dSINE rupture site in agreement with lengthy transient simulations. Consequently, our developed approach may be of value in treatment planning where a fast assessment of the local hemodynamic environment is essential.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Rotura de la Aorta Tipo de estudio: Qualitative_research Límite: Humans Idioma: En Revista: Thorac Cardiovasc Surg Año: 2024 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Rotura de la Aorta Tipo de estudio: Qualitative_research Límite: Humans Idioma: En Revista: Thorac Cardiovasc Surg Año: 2024 Tipo del documento: Article País de afiliación: Alemania