Your browser doesn't support javascript.
loading
Assessment of infant gonadal dose irradiated from urine-contaminated diapers during diuretic renal scintigraphy.
Lu, Yonggang; Kumbhar, Sachin; Liu, Yu; Vo, Nghia Jack; Lu, Jerry; Baker, Marjorie; Qi, Jing.
Afiliación
  • Lu Y; Department of Radiology, Medical College of Wisconsin, Milwaukee, Wisconsin, .
  • Kumbhar S; Department of Radiology, Virginia Mason Medical Center, Seattle, Washington, .
  • Liu Y; Department of Radiology, Medical College of Wisconsin, Milwaukee, Wisconsin, .
  • Vo NJ; Department of Radiology, Medical College of Wisconsin, Milwaukee, Wisconsin, .
  • Lu J; College of Human Ecology, Cornell University, Ithaca, New York and .
  • Baker M; Department of Radiology, Children's Hospital of Wisconsin, Milwaukee, Wisconsin, USA.
  • Qi J; Department of Radiology, Medical College of Wisconsin, Milwaukee, Wisconsin, .
Nucl Med Commun ; 45(1): 45-50, 2024 Jan 01.
Article en En | MEDLINE | ID: mdl-37901921
ABSTRACT

OBJECTIVE:

To estimate the gonadal doses irradiated from urine- contaminated diapers during diuretic renal scintigraphy.

METHODS:

Images of 31 patients (18 males and 13 females) with urine-contaminated diapers during 99m Tc-MAG3 renal scintigraphy were analyzed. The count rate of the diapers was converted into a time-activity curve based on the calibrated factor of the gamma camera system. The cumulative activity was determined from the area under the curve. By incorporating dose per unit cumulative activity pre-calculated from Monte Carlo simulation with 0-year phantom, the gonadal dose irradiated from diaper was calculated. To assess the degree of this additionally introduced dose from diapers, the calculated gonadal dose was compared to the internal gonadal dose from injected radiotracer activity.

RESULTS:

The cumulative activities irradiated from urine-contaminated diapers were 1.12 E04 ±â€…1.29E04 MBq.s in male infants, which was nearly half of the 1.94 E04 ±â€…1.80E04 MBq.s ( P  = 0.15) in female infants. However, the absorbed doses for testes in male infants were 7.37E-01 ±â€…8.50E-01 mGy, which was approximately 10 times the 6.38E-02 ±â€…5.94E-02 mGy for ovaries in female infants ( P  < 0.01). The diaper-introduced dose for testes and ovaries was 91.7% and 3.9% of the gonadal doses from the injected activity in patients with normal renal function, and 99.0% and 4.3% of those in patients with abnormal renal function.

CONCLUSION:

Urine-contaminated diapers introduced additional radiation doses to infant patients during 99m Tc-MAG3 renal scintigraphy. The gonadal doses were of significance in male infants who had nearly double the absorbed dose for the testes.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Diuréticos / Cuidado del Lactante Límite: Child / Female / Humans / Infant / Male Idioma: En Revista: Nucl Med Commun Año: 2024 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Diuréticos / Cuidado del Lactante Límite: Child / Female / Humans / Infant / Male Idioma: En Revista: Nucl Med Commun Año: 2024 Tipo del documento: Article