Your browser doesn't support javascript.
loading
Assessing airborne transmission risks in COVID-19 hospitals by systematically monitoring SARS-CoV-2 in the air.
Li, Shanglin; Guo, Jiazhen; Gu, Yin; Meng, Yan; He, Ming; Yang, Shangzhi; Ge, Ziruo; Wang, Guanjun; Yang, Yi; Jin, Ronghua; Lu, Lianhe; Liu, Peng.
Afiliación
  • Li S; Department of Biomedical Engineering, School of Medicine, Tsinghua University , Beijing, China.
  • Guo J; Changping Laboratory , Beijing, China.
  • Gu Y; Beijing Ditan Hospital, Capital Medical University , Beijing, China.
  • Meng Y; State Key Laboratory of Space Medicine Fundamentals and Application, China Astronaut Research and Training Center , Beijing, China.
  • He M; Beijing Ditan Hospital, Capital Medical University , Beijing, China.
  • Yang S; Beijing Ditan Hospital, Capital Medical University , Beijing, China.
  • Ge Z; Beijing Zijing Biotechnology Co., Ltd. , Beijing, China.
  • Wang G; Beijing Ditan Hospital, Capital Medical University , Beijing, China.
  • Yang Y; Beijing Zijing Biotechnology Co., Ltd. , Beijing, China.
  • Jin R; Beijing Zijing Biotechnology Co., Ltd. , Beijing, China.
  • Lu L; Beijing Ditan Hospital, Capital Medical University , Beijing, China.
  • Liu P; Beijing Ditan Hospital, Capital Medical University , Beijing, China.
Microbiol Spectr ; 11(6): e0109923, 2023 Dec 12.
Article en En | MEDLINE | ID: mdl-37937995
ABSTRACT
IMPORTANCE Risk management and control of airborne transmission in hospitals is crucial in response to a respiratory virus pandemic. However, the formulation of these infection control measures is often based on epidemiological investigations, which are an indirect way of analyzing the transmission route of viruses. This can lead to careless omissions in infection prevention and control or excessively restrictive measures that increase the burden on healthcare workers. The study provides a starting point for standardizing transmission risk management in designated hospitals by systemically monitoring viruses in the air of typical spaces in COVID-19 hospitals. The negative results of 359 air samples in the clean and emergency zones demonstrated the existing measures to interrupt airborne transmission in a designated COVID-19 hospital. Some positive cases in the corridor of the contaminant zone during rounds and meal delivery highlighted the importance of monitoring airborne viruses for interrupting nosocomial infection.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: COVID-19 Límite: Humans Idioma: En Revista: Microbiol Spectr Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: COVID-19 Límite: Humans Idioma: En Revista: Microbiol Spectr Año: 2023 Tipo del documento: Article País de afiliación: China