Your browser doesn't support javascript.
loading
Two-way adjustable double-knots intrascleral fixation and single sclerotomy looping technique: a novel minimal invasive adjustable intraocular lens fixation technique.
Chen, Lulu; Wang, Zaowen; Sun, Lu; Tang, Yongxiang; Sui, Wenda; Bian, Ailing; Zhang, Xia; Zhong, Yong; Zhang, Shunhua.
Afiliación
  • Chen L; Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, No.1 Shuaifuyuan Wangfujing Dongcheng District, 100730, Beijing, China.
  • Wang Z; Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, No.1 Shuaifuyuan Wangfujing Dongcheng District, 100730, Beijing, China. wzwpumch@126.com.
  • Sun L; Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, No.1 Shuaifuyuan Wangfujing Dongcheng District, 100730, Beijing, China.
  • Tang Y; Department of Ophthalmology, The Affiliated Hospital of Zunyi Medical University, 563000, Zunyi, Guizhou, China.
  • Sui W; Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, No.1 Shuaifuyuan Wangfujing Dongcheng District, 100730, Beijing, China.
  • Bian A; Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, No.1 Shuaifuyuan Wangfujing Dongcheng District, 100730, Beijing, China.
  • Zhang X; Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, No.1 Shuaifuyuan Wangfujing Dongcheng District, 100730, Beijing, China.
  • Zhong Y; Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, No.1 Shuaifuyuan Wangfujing Dongcheng District, 100730, Beijing, China.
  • Zhang S; Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, No.1 Shuaifuyuan Wangfujing Dongcheng District, 100730, Beijing, China.
BMC Ophthalmol ; 23(1): 481, 2023 Nov 23.
Article en En | MEDLINE | ID: mdl-37996816

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Implantación de Lentes Intraoculares / Lentes Intraoculares Límite: Humans Idioma: En Revista: BMC Ophthalmol Asunto de la revista: OFTALMOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Implantación de Lentes Intraoculares / Lentes Intraoculares Límite: Humans Idioma: En Revista: BMC Ophthalmol Asunto de la revista: OFTALMOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: China