Minimizing artifact-induced false-alarms for seizure detection in wearable EEG devices with gradient-boosted tree classifiers.
Ingolfsson, Thorir Mar; Benatti, Simone; Wang, Xiaying; Bernini, Adriano; Ducouret, Pauline; Ryvlin, Philippe; Beniczky, Sandor; Benini, Luca; Cossettini, Andrea.
Afiliación
  • Ingolfsson TM; ETH Zürich, D-ITET, 8092, Zürich, Switzerland. thoriri@iis.ee.ethz.ch.
  • Benatti S; University of Bologna, 40126, Bologna, Italy.
  • Wang X; University of Modena and Reggio Emilia, 41121, Reggio Emilia, Italy.
  • Bernini A; ETH Zürich, D-ITET, 8092, Zürich, Switzerland.
  • Ducouret P; University Hospital of Lausanne (CHUV), 1011, Lausanne, Switzerland.
  • Ryvlin P; University Hospital of Lausanne (CHUV), 1011, Lausanne, Switzerland.
  • Beniczky S; University Hospital of Lausanne (CHUV), 1011, Lausanne, Switzerland.
  • Benini L; Aarhus University Hospital, 8200, Aarhus, Denmark.
  • Cossettini A; Danish Epilepsy Centre (Filadelfia), 4293, Dianalund, Denmark.
Sci Rep ; 14(1): 2980, 2024 02 05.
Article en En | MEDLINE | ID: mdl-38316856
ABSTRACT
Electroencephalography (EEG) is widely used to monitor epileptic seizures, and standard clinical practice consists of monitoring patients in dedicated epilepsy monitoring units via video surveillance and cumbersome EEG caps. Such a setting is not compatible with long-term tracking under typical living conditions, thereby motivating the development of unobtrusive wearable solutions. However, wearable EEG devices present the challenges of fewer channels, restricted computational capabilities, and lower signal-to-noise ratio. Moreover, artifacts presenting morphological similarities to seizures act as major noise sources and can be misinterpreted as seizures. This paper presents a combined seizure and artifacts detection framework targeting wearable EEG devices based on Gradient Boosted Trees. The seizure detector achieves nearly zero false alarms with average sensitivity values of [Formula see text] for 182 seizures from the CHB-MIT dataset and [Formula see text] for 25 seizures from the private dataset with no preliminary artifact detection or removal. The artifact detector achieves a state-of-the-art accuracy of [Formula see text] (on the TUH-EEG Artifact Corpus dataset). Integrating artifact and seizure detection significantly reduces false alarms-up to [Formula see text] compared to standalone seizure detection. Optimized for a Parallel Ultra-Low Power platform, these algorithms enable extended monitoring with a battery lifespan reaching 300 h. These findings highlight the benefits of integrating artifact detection in wearable epilepsy monitoring devices to limit the number of false positives.