Assessment of Swallowing Function in Healthy Adults While Using High-Flow Nasal Cannula.
Graf, Alexander E; Mehl, Alla; De Costa, Amelia; Rosenfeld, Richard M; Abu-Ghanem, Sara.
Afiliación
  • Graf AE; Department of Otolaryngology, SUNY Downstate Health Sciences University, Brooklyn, USA.
  • Mehl A; Division of Speech-Language Pathology, Orthopedics & Rehabilitation Center, Maimonides Health, Brooklyn, USA.
  • De Costa A; Division of Speech-Language Pathology, Orthopedics & Rehabilitation Center, Maimonides Health, Brooklyn, USA.
  • Rosenfeld RM; Department of Otolaryngology, SUNY Downstate Health Sciences University, Brooklyn, USA.
  • Abu-Ghanem S; Department of Otolaryngology, SUNY Downstate Health Sciences University, Brooklyn, USA.
Otolaryngol Head Neck Surg ; 170(5): 1372-1379, 2024 May.
Article en En | MEDLINE | ID: mdl-38353344
ABSTRACT

OBJECTIVE:

Despite widespread use of high flow nasal cannula (HFNC) for respiratory support, the effect of HFNC on swallowing physiology is poorly understood. Flow rates that permit safe swallowing have not been established. We aim to assess if healthy individuals have diminished swallowing function and safety at high flow rates. STUDY

DESIGN:

Repeated measures with planned data collection.

SETTING:

Outpatient dysphagia clinic.

METHODS:

Swallowing function in a cohort of healthy individuals was assessed using Flexible Endoscopic Evaluation of Swallowing (FEES). Participants' safety of swallowing was assessed with different textures under randomized rates of HFNC (0, 30, 40, 50, and 60 LPM). Swallowing trials included quantities of thin liquids, mildly-thick liquids, and purees. Trials were scored using the Penetration-Aspiration Scale (PAS). Pearson chi-square tests were used to test for correlation between PAS result, flow rate, and consistency across each quantity of material.

RESULTS:

Twenty-seven subjects were enrolled. Forty-one percent were male with mean age of 34 years (11 standard deviation). Ninety-nine percent (267/270), 97% (n = 263/270), and 99% (399/405) of 1 sip swallows, 3 sip swallows, and 5 mL swallows, respectively, were safe. There was no significant correlation between swallow safety and flow rate using Pearson Chi-Square test across all consistencies and across all quantities of materials (P > 0.05). Of note, out of all subtrials, the thin liquid, 3 sips trial at 60 LPM, had the largest percent of unsafe swallows (14%).

CONCLUSION:

Our results suggest rate of aspiration is not significantly affected by high flow nasal cannula in healthy individuals.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Deglución / Cánula Tipo de estudio: Clinical_trials Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Otolaryngol Head Neck Surg Asunto de la revista: OTORRINOLARINGOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Deglución / Cánula Tipo de estudio: Clinical_trials Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Otolaryngol Head Neck Surg Asunto de la revista: OTORRINOLARINGOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos