Your browser doesn't support javascript.
loading
Diffusivities and Atomic Mobilities in BCC Ti-Fe-Cr Alloys.
Huang, Yi; Nie, Jingjing; Bai, Weimin; Hu, Songsong; Wang, Xinming; Zhang, Ligang; Liu, Libin.
Afiliación
  • Huang Y; School of Materials Science and Engineering, Xiangtan University, Xiangtan 411105, China.
  • Nie J; Key Laboratory of Materials Design and Preparation Technology of Hunan Province, Xiangtan University, Xiangtan 411105, China.
  • Bai W; School of Materials Science and Engineering, Xiangtan University, Xiangtan 411105, China.
  • Hu S; Key Laboratory of Materials Design and Preparation Technology of Hunan Province, Xiangtan University, Xiangtan 411105, China.
  • Wang X; School of Materials Science and Engineering, Xiangtan University, Xiangtan 411105, China.
  • Zhang L; Key Laboratory of Materials Design and Preparation Technology of Hunan Province, Xiangtan University, Xiangtan 411105, China.
  • Liu L; School of Materials Science and Engineering, Xiangtan University, Xiangtan 411105, China.
Materials (Basel) ; 17(8)2024 Apr 22.
Article en En | MEDLINE | ID: mdl-38673284
ABSTRACT
In this research, the diffusion behaviors within the Ti-Fe-Cr ternary system were examined at the temperatures of 1273 K and 1373 K through the diffusion couple technique. This study led to the determination of both ternary inter-diffusion and impurity diffusion coefficients in the body-centered cubic (bcc) phase for the Ti-Fe-Cr alloy, utilizing the Whittle-Green and Hall methods. The statistics show that the average diffusion coefficients D˜FeFeTi and D˜CrCrTi measured at 1273 K were 1.34 × 10-12 and 3.66 × 10-13, respectively. At 1373 K, the average values of D˜FeFeTi and D˜CrCrTi were 4.89 × 10-12 and 1.43 × 10-12. By adopting the CALPHAD method, a self-consistent database for atomic mobility in the bcc phase of the Ti-Fe-Cr system was established. This database underwent refinement by comparing the newly acquired diffusion coefficients with data from the existing literature. Diffusion simulations for the diffusion couples were performed, drawing on the established database. The error between the simulated diffusion coefficient and the experimental measurement data is within 15%, and the simulated data of the component distance distribution and diffusion path are in good agreement with the experimental data. The simulations generated results that aligned well with the observed experimental diffusion characteristics, thereby affirming the reliability and accuracy of the database.
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: Materials (Basel) Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: Materials (Basel) Año: 2024 Tipo del documento: Article País de afiliación: China