Your browser doesn't support javascript.
loading
A Silicon-Based ROTE Sensor for High-Q and Label-Free Carcinoembryonic Antigen Detection.
Sang, Luxiao; Liang, Haojie; Zhao, Biao; Shi, Runze; Jian, Aoqun; Sang, Shengbo.
Afiliación
  • Sang L; Shanxi Key Laboratory of Micro-Nano Sensors & Artificial Intelligence Perception, College of Electronic Information and Optical Engineering, Taiyuan University of Technology, Taiyuan 030024, China.
  • Liang H; Key Laboratory of Advanced Transducers and Intelligent Control System, Ministry of Education, Taiyuan University of Technology, Taiyuan 030024, China.
  • Zhao B; Shanxi Key Laboratory of Micro-Nano Sensors & Artificial Intelligence Perception, College of Electronic Information and Optical Engineering, Taiyuan University of Technology, Taiyuan 030024, China.
  • Shi R; Key Laboratory of Advanced Transducers and Intelligent Control System, Ministry of Education, Taiyuan University of Technology, Taiyuan 030024, China.
  • Jian A; Shanxi Research Institute of 6D Artificial Intelligence Biomedical Science, Taiyuan 030031, China.
  • Sang S; Shanxi Key Laboratory of Micro-Nano Sensors & Artificial Intelligence Perception, College of Electronic Information and Optical Engineering, Taiyuan University of Technology, Taiyuan 030024, China.
Micromachines (Basel) ; 15(5)2024 Apr 27.
Article en En | MEDLINE | ID: mdl-38793154
ABSTRACT
This paper presents a biosensor based on the resonant optical tunneling effect (ROTE) for detecting a carcinoembryonic antigen (CEA). In this design, sensing is accomplished through the interaction of the evanescent wave with the CEA immobilized on the sensor's surface. When CEA binds to the anti-CEA, it alters the effective refractive index (RI) on the sensor's surface, leading to shifts in wavelength. This shift can be identified through the cascade coupling of the FP cavity and ROTE cavity in the same mode. Experimental results further show that the shift in resonance wavelength increases with the concentration of CEA. The biosensor responded linearly to CEA concentrations ranging from 1 to 5 ng/mL with a limit of detection (LOD) of 0.5 ng/mL and a total Q factor of 9500. This research introduces a new avenue for identifying biomolecules and cancer biomarkers, which are crucial for early cancer detection.