Your browser doesn't support javascript.
loading
Diagnostic value of combined ultrasound contrast and elastography for differentiating benign and malignant thyroid nodules: a meta-analysis.
Liu, Funing; Wang, Yihan; Xiong, Yu; Li, Xin; Yao, Jun; Ju, Hao; Ren, Fu; Zhang, Luwei; Wang, Hongbo.
Afiliación
  • Liu F; School of First Clinical College, Shenyang Medical College, Shenyang, People's Republic of China.
  • Wang Y; School of Public Health, Shenyang Medical College, Shenyang, People's Republic of China.
  • Xiong Y; School of First Clinical College, Shenyang Medical College, Shenyang, People's Republic of China.
  • Li X; School of Stomatology, Shenyang Medical College, Shenyang, People's Republic of China.
  • Yao J; School of Forensic Medicine, China Medical University, Shenyang, People's Republic of China.
  • Ju H; Shengjing Hospital of China Medical University, Shenyang, People's Republic of China.
  • Ren F; Department of Human Anatomy, School of Basic Medicine, Shenyang Medical College, Shenyang, People's Republic of China.
  • Zhang L; Key Laboratory of Human Ethnic Specificity and Phenomics of Critical Illness in Liaoning Province, Shenyang, People's Republic of China.
  • Wang H; Key Laboratory of Phenomics Research, No.146, Huanghe North Street, Shenyang, 110034, Liaoning, People's Republic of China.
Sci Rep ; 14(1): 12605, 2024 06 01.
Article en En | MEDLINE | ID: mdl-38824246
ABSTRACT
The diagnostic value of contrast-enhanced ultrasound combined with ultrasound elastography for benign and malignant thyroid nodules is still controversial, so we used meta-analysis to seek controversial answers. The PubMed, OVID, and CNKI databases were searched according to the inclusion and exclusion criteria. The literature was selected from the establishment of each database to February 2024. The QUADAS-2 tool assessed diagnostic test accuracy. SROC curves and Spearman's correlation coefficient were made by Review Manager 5.4 software to assess the presence of threshold effects in the literature. Meta-Disc1.4 software was used for Cochrane-Q and χ2 tests, which be used to evaluate heterogeneity, with P-values and I2 indicating heterogeneity levels. The appropriate effect model was selected based on the results of the heterogeneity test. Stata18.0 software was used to evaluate publication bias. The diagnostic accuracy of contrast-enhanced ultrasound combined with ultrasound elastography for benign and malignant thyroid nodules was evaluated by calculating the combined sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, DOR, and area under the SROC curve. A total of 31 studies included 3811 patients with 4718 nodules were analyzed. There is no heterogeneity caused by the threshold effect, but there is significant non-threshold heterogeneity. Combined diagnostic metrics were sensitivity = 0.93, specificity = 0.91, DOR = 168.41, positive likelihood ratio = 10.60, and negative likelihood ratio = 0.07. The SROC curve area was 0.97. Contrast-enhanced ultrasound and elastography show high diagnostic accuracy for thyroid nodules, offering a solid foundation for early diagnosis and treatment.Trial registration. CRD42024509462.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Ultrasonografía / Nódulo Tiroideo / Medios de Contraste / Diagnóstico por Imagen de Elasticidad Límite: Humans Idioma: En Revista: Sci Rep / Sci. rep. (Nat. Publ. Group) / Scientific reports (Nature Publishing Group) Año: 2024 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Ultrasonografía / Nódulo Tiroideo / Medios de Contraste / Diagnóstico por Imagen de Elasticidad Límite: Humans Idioma: En Revista: Sci Rep / Sci. rep. (Nat. Publ. Group) / Scientific reports (Nature Publishing Group) Año: 2024 Tipo del documento: Article